Abstract: In this paper, we focus on the design of a multi-line
copper wire (MLCW) communication system. First, we construct
our proposed MLCW channel and verify its characteristics based
on the Kolmogorov-Smirnov test. In addition, we apply Middleton
class A impulsive noise (IN) to the copper channel for further
investigation. Second, the MIMO G.fast system is adopted utilizing
the proposed MLCW channel model and is compared to a single
line G-fast system. Second, the performance of the coded system
is obtained utilizing concatenated interleaved Reed-Solomon (RS)
code with four-dimensional trellis-coded modulation (4D TCM), and
compared to the single line G-fast system. Simulations are obtained
for high quadrature amplitude modulation (QAM) constellations
that are commonly used with G-fast communications, the results
demonstrate that the bit error rate (BER) performance of the coded
MLCW system shows an improvement compared to the single line
G-fast systems.
Abstract: This paper presents a subband adaptive filter (SAF)
for a system identification where an impulse response is sparse
and disturbed with an impulsive noise. Benefiting from the uses
of l1-norm optimization and l0-norm penalty of the weight vector
in the cost function, the proposed l0-norm sign SAF (l0-SSAF)
achieves both robustness against impulsive noise and much improved
convergence behavior than the classical adaptive filters. Simulation
results in the system identification scenario confirm that the proposed
l0-norm SSAF is not only more robust but also faster and more
accurate than its counterparts in the sparse system identification in
the presence of impulsive noise.
Abstract: We present a new subband adaptive filter (R-SAF)
which is robust against impulsive noise in system identification. To
address the vulnerability of adaptive filters based on the L2-norm
optimization criterion against impulsive noise, the R-SAF comes from
the L1-norm optimization criterion with a constraint on the energy
of the weight update. Minimizing L1-norm of the a posteriori error
in each subband with a constraint on minimum disturbance gives
rise to the robustness against the impulsive noise and the capable
convergence performance. Experimental results clearly demonstrate
that the proposed R-SAF outperforms the classical adaptive filtering
algorithms when impulsive noise as well as background noise exist.
Abstract: The Orthogonal Frequency Division Multiplexing
(OFDM) with high data rate, high spectral efficiency and its ability to
mitigate the effects of multipath makes them most suitable in wireless
application. Impulsive noise distorts the OFDM transmission and
therefore methods must be investigated to suppress this noise. In this
paper, a State Space Recursive Least Square (SSRLS) algorithm
based adaptive impulsive noise suppressor for OFDM
communication system is proposed. And a comparison with another
adaptive algorithm is conducted. The state space model-dependent
recursive parameters of proposed scheme enables to achieve steady
state mean squared error (MSE), low bit error rate (BER), and faster
convergence than that of some of existing algorithm.
Abstract: Medical image segmentation based on image smoothing followed by edge detection assumes a great degree of importance in the field of Image Processing. In this regard, this paper proposes a novel algorithm for medical image segmentation based on vigorous smoothening by identifying the type of noise and edge diction ideology which seems to be a boom in medical image diagnosis. The main objective of this algorithm is to consider a particular medical image as input and make the preprocessing to remove the noise content by employing suitable filter after identifying the type of noise and finally carrying out edge detection for image segmentation. The algorithm consists of three parts. First, identifying the type of noise present in the medical image as additive, multiplicative or impulsive by analysis of local histograms and denoising it by employing Median, Gaussian or Frost filter. Second, edge detection of the filtered medical image is carried out using Canny edge detection technique. And third part is about the segmentation of edge detected medical image by the method of Normalized Cut Eigen Vectors. The method is validated through experiments on real images. The proposed algorithm has been simulated on MATLAB platform. The results obtained by the simulation shows that the proposed algorithm is very effective which can deal with low quality or marginal vague images which has high spatial redundancy, low contrast and biggish noise, and has a potential of certain practical use of medical image diagnosis.
Abstract: The goal of speech parameterization is to extract the relevant information about what is being spoken from the audio signal. In speech recognition systems Mel-Frequency Cepstral Coefficients (MFCC) and Relative Spectral Mel-Frequency Cepstral Coefficients (RASTA-MFCC) are the two main techniques used. It will be shown in this paper that it presents some modifications to the original MFCC method. In our work the effectiveness of proposed changes to MFCC called Modified Function Cepstral Coefficients (MODFCC) were tested and compared against the original MFCC and RASTA-MFCC features. The prosodic features such as jitter and shimmer are added to baseline spectral features. The above-mentioned techniques were tested with impulsive signals under various noisy conditions within AURORA databases.
Abstract: This paper shows how we can integrate
communication modeling into the design modeling at early stages of
the design flow. We consider effect of incorporating noise such as
impulsive noise on system stability. We show that with change of the
system model and investigate the system performance under the
different communication effects. We modeled a unmanned aerial
vehicle (UAV) as a demonstration using SystemC methodology.
Moreover the system is modeled by joining the capabilities of UML
and SystemC to operate at system level.
Abstract: power-line networks are promise infrastructure for
broadband services provision to end users. However, the network
performance is affected by stochastic channel changing which is due
to load impedances, number of branches and branched line lengths. It
has been proposed that multi-carrier modulations techniques such as
orthogonal frequency division multiplexing (OFDM), Multi-Carrier
Spread Spectrum (MC-SS), wavelet OFDM can be used in such
environment. This paper investigates the performance of different
indoor topologies of power-line networks that uses MC-SS
modulation scheme.It is observed that when a branch is added in the
link between sending and receiving end of an indoor channel an
average of 2.5dB power loss is found. In additional, when the branch
is added at a node an average of 1dB power loss is found.
Additionally when the terminal impedances of the branch change
from line characteristic impedance to impedance either higher or
lower values the channel performances were tremendously improved.
For example changing terminal load from characteristic impedance
(85 .) to 5 . the signal to noise ratio (SNR) required to attain the
same performances were decreased from 37dB to 24dB respectively.
Also, changing the terminal load from channel characteristic
impedance (85 .) to very higher impedance (1600 .) the SNR
required to maintain the same performances were decreased from
37dB to 23dB. The result concludes that MC-SS performs better
compared with OFDM techniques in all aspects and especially when
the channel is terminated in either higher or lower impedances.
Abstract: COSMED K4b2 is a portable electrical device designed to test pulmonary functions. It is ideal for many applications that need the measurement of the cardio-respiratory response either in the field or in the lab is capable with the capability to delivery real time data to a sink node or a PC base station with storing data in the memory at the same time. But the actual sensor outputs and data received may contain some errors, such as impulsive noise which can be related to sensors, low batteries, environment or disturbance in data acquisition process. These abnormal outputs might cause misinterpretations of exercise or living activities to persons being monitored. In our paper we propose an effective and feasible method to detect and identify errors in applications by principal component analysis (PCA) and a back propagation (BP) neural network.
Abstract: The problem of FIR system parameter estimation has been considered in the paper. A new robust recursive algorithm for simultaneously estimation of parameters and scale factor of prediction residuals in non-stationary environment corrupted by impulsive noise has been proposed. The performance of derived algorithm has been tested by simulations.
Abstract: This paper introduces a new approach for the performance
analysis of adaptive filter with error saturation nonlinearity in
the presence of impulsive noise. The performance analysis of adaptive
filters includes both transient analysis which shows that how fast
a filter learns and the steady-state analysis gives how well a filter
learns. The recursive expressions for mean-square deviation(MSD)
and excess mean-square error(EMSE) are derived based on weighted
energy conservation arguments which provide the transient behavior
of the adaptive algorithm. The steady-state analysis for co-related
input regressor data is analyzed, so this approach leads to a new
performance results without restricting the input regression data to
be white.
Abstract: In this paper, we propose a method to reduce the
various kinds of noise while gathering and recording the
electrocardiogram (ECG) signal. Because of the defects of former
method in the noise elimination of ECG signal, we use translation
invariant (TI) multiwavelet denoising method to the noise elimination.
The advantage of the proposed method is that it may not only remain
the geometrical characteristics of the original ECG signal and keep the
amplitudes of various ECG waveforms efficiently, but also suppress
impulsive noise to some extent. The simulation results indicate that the
proposed method are better than former removing noise method in
aspects of remaining geometrical characteristics of ECG signal and the
signal-to-noise ratio (SNR).