Abstract: The purpose of this research is to analyze the gait
strategy between the normal and loaded gait. To this end, five male
participants satisfied two conditions: the normal and loaded gait
(backpack load 25.2 kg). As expected, results showed that additional
loads elicited not a proportional increase in vertical and shear ground
reaction force (GRF) parameters but also increase of the impulse,
momentum and mechanical work. However, in case of the loaded gait,
the time duration of the double support phase was increased
unexpectedly. It is because the double support phase which is more
stable than the single support phase can reduce instability of the
loaded gait. Also, the directions of the pre-collision and after-collision
were moved upward and downward compared to the normal gait. As a
result, regardless of the additional backpack load, the
impulse-momentum diagram during the step-to-step transition was
maintained such as the normal gait. It means that human walk
efficiently to keep stability and minimize total net works in case of the
loaded gait.
Abstract: This paper describes an ab-initio design, development and calibration results of an Optical Sensor Ground Reaction Force Measurement Platform (OSGRFP) for gait and geriatric studies. The developed system employs an array of FBG sensors to measure the respective ground reaction forces from all three axes (X, Y and Z), which are perpendicular to each other. The novelty of this work is two folded. One is in its uniqueness to resolve the tri axial resultant forces during the stance in to the respective pure axis loads and the other is the applicability of inherently advantageous FBG sensors which are most suitable for biomechanical instrumentation. To validate the response of the FBG sensors installed in OSGRFP and to measure the cross sensitivity of the force applied in other directions, load sensors with indicators are used. Further in this work, relevant mathematical formulations are presented for extracting respective ground reaction forces from wavelength shifts/strain of FBG sensors on the OSGRFP. The result of this device has implications in understanding the foot function, identifying issues in gait cycle and measuring discrepancies between left and right foot. The device also provides a method to quantify and compare relative postural stability of different subjects under test, which has implications in post-surgical rehabilitation, geriatrics and optimizing training protocols for sports personnel.
Abstract: GRF, Growth regulating factor, genes encode a novel
class of plant-specific transcription factors. The GRF proteins play a
role in the regulation of cell numbers in young and growing tissues
and may act as transcription activations in growth and development
of plants. Identification of GRF genes and their expression are
important in plants to performance of the growth and development of
various organs. In this study, to better understanding the structural
and functional differences of GRFs family, 45 GRF proteins
sequences in A. thaliana, Z. mays, O. sativa, B. napus, B. rapa, H.
vulgare and S. bicolor, have been collected and analyzed through
bioinformatics data mining. As a result, in secondary structure of
GRFs, the number of alpha helices was more than beta sheets and in
all of them QLQ domains were completely in the biggest alpha helix.
In all GRFs, QLQ and WRC domains were completely protected
except in AtGRF9. These proteins have no trans-membrane domain
and due to have nuclear localization signals act in nuclear and they
are component of unstable proteins in the test tube.
Abstract: Kinematic data wisely correlate vector quantities in
space to scalar parameters in time to assess the degree of symmetry
between the intact limb and the amputated limb with respect to a
normal model derived from the gait of control group participants.
Furthermore, these particular data allow a doctor to preliminarily
evaluate the usefulness of a certain rehabilitation therapy.
Kinetic curves allow the analysis of ground reaction forces (GRFs)
to assess the appropriateness of human motion.
Electromyography (EMG) allows the analysis of the fundamental
lower limb force contributions to quantify the level of gait
asymmetry. However, the use of this technological tool is expensive
and requires patient’s hospitalization. This research work suggests
overcoming the above limitations by applying artificial neural
networks.
Abstract: This research contribution is drafted to present the
orbit design, orbit propagator and geomagnetic field estimator for the
nanosatellites specifically for the upcoming CUBESAT, ICUBE-1 of
the Institute of Space Technology (IST), Islamabad, Pakistan. The
ICUBE mission is designed for the low earth orbit at the approximate
height of 700KM. The presented research endeavor designs the
Keplarian elements for ICUBE-1 orbit while incorporating the
mission requirements and propagates the orbit using J2 perturbations,
The attitude determination system of the ICUBE-1 consists of
attitude determination sensors like magnetometer and sun sensor. The
Geomagnetic field estimator is developed according to the model of
International Geomagnetic Reference Field (IGRF) for comparing the
magnetic field measurements by the magnetometer for attitude
determination. The output of the propagator namely the Keplarians
position and velocity vectors and the magnetic field vectors are
compared and verified with the same scenario generated in the
Satellite Tool Kit (STK).