Abstract: Organic Flash Cycle (OFC) has potential of improving
efficiency for recovery of low temperature heat sources mainly due to
reducing temperature mismatch in the heat exchanger. In this work
exergetical performance analysis of ORC is conducted for recovery of
low grade heat source. Effects of system parameters such as flash
evaporation temperature or heating temperature are theoretically
investigated on the exergy destructions (anergies) at various
components of the system as well as exergy efficiency. Results show
that exergy efficiency has a peak with respect to the flash temperature,
and the optimum flash temperature increases with the heating
temperature. The component where the largest exergy destruction
occurs varies with the flash temperature or heating temperature.
Abstract: This paper presents the results of preliminary
assessment of water quality along the coastal areas in the vicinity of
Left Bank Outfall Drainage (LBOD) and Tidal Link Drain (TLD) in
Sindh province after the cyclone 2A occurred in 1999. The water
samples were collected from various RDs of Tidal Link Drain and
lakes during September 2001 to April 2002 and were analysed for
salinity, nitrite, phosphate, ammonia, silicate and suspended material
in water. The results of the study showed considerable variations in
water quality depending upon the location along the coast in the
vicinity of LBOD and RDs. The salinity ranged between 4.39–65.25
ppt in Tidal Link Drain samples whereas 2.4–38.05 ppt in samples
collected from lakes. The values of suspended material at various
RDs of Tidal Link Drain ranged between 56.6–2134 ppm and at the
lakes between 68–297 ppm. The data of continuous monitoring at
RD–93 showed the range of PO4 (8.6–25.2 μg/l), SiO3 (554.96–1462
μg/l), NO2 (0.557.2–25.2 μg/l) and NH3 (9.38–23.62 μg/l). The
concentration of nutrients in water samples collected from different
RDs was found in the range of PO4 (10.85 to 11.47 μg/l), SiO3 (1624
to 2635.08 μg/l), NO2 (20.38 to 44.8 μg/l) and NH3 (24.08 to 26.6
μg/l). Sindh coastal areas which situated at the north-western
boundary the Arabian Sea are highly vulnerable to flood damages
due to flash floods during SW monsoon or impact of sea level rise
and storm surges coupled with cyclones passing through Arabian Sea
along Pakistan coast. It is hoped that the obtained data in this study
would act as a database for future investigations and monitoring of
LBOD and Tidal Link Drain coastal waters.
Abstract: Modern Society is strongly dependent on a reliable
power supply. The availability of cheap and reliable supply of
electrical energy is an indicator of societal welfare. Uninterrupted
reliable operation of a modern power system depends to a great
extent on reliable and satisfactory performance of insulators under
different environmental conditions. This paper reports result of
natural pollution tests that have been done at sites around city of
Aligarh (India). Flashover voltage per insulation distance (FOVUID)
of porcelain disc insulator for different pH values, ESDD has been
recorded for proper correlation between electrical and chemical
parameters. The pH of the contaminants has been suggested to be an
effective pollution severity indicator and may be used as a diagnostic
parameter for proper maintenance of porcelain insulators.