Abstract: With the rapid increase of grid-connected PV systems over the last decades, genuine challenges have arisen for engineers and professionals of energy field in the planning and operation of existing distribution networks with the integration of new generation sources. However, the conventional distribution network, in its design was not expected to receive other generation outside the main power supply. The tools generally used to analyze the networks become inefficient and cannot take into account all the constraints related to the operation of grid-connected PV systems. Some of these constraints are voltage control difficulty, reverse power flow, and especially voltage unbalance which could be due to the poor distribution of single-phase PV systems in the network. In order to analyze the impact of the connection of small and large number of PV systems to the distribution networks, this paper presents an efficient optimization tool that minimizes voltage unbalance in three-phase distribution networks with active and reactive power injections from the allocation of single-phase and three-phase PV plants. Reactive power can be generated or absorbed using the available capacity and the adjustable power factor of the inverter. Good reduction of voltage unbalance can be achieved by reactive power control of the PV systems. The presented tool is based on the three-phase current injection method and the PV systems are modeled via an equivalent circuit. The primal-dual interior point method is used to obtain the optimal operating points for the systems.
Abstract: The harmonic distortion of voltage is important in relation to power quality due to the interaction between the large diffusion of non-linear and time-varying single-phase and three-phase loads with power supply systems. However, harmonic distortion levels can be reduced by improving the design of polluting loads or by applying arrangements and adding filters. The application of passive filters is an effective solution that can be used to achieve harmonic mitigation mainly because filters offer high efficiency, simplicity, and are economical. Additionally, possible different frequency response characteristics can work to achieve certain required harmonic filtering targets. With these ideas in mind, the objective of this paper is to determine what size single tuned passive filters work in distribution networks best, in order to economically limit violations caused at a given point of common coupling (PCC). This article suggests that a single tuned passive filter could be employed in typical industrial power systems. Furthermore, constrained optimization can be used to find the optimal sizing of the passive filter in order to reduce both harmonic voltage and harmonic currents in the power system to an acceptable level, and, thus, improve the load power factor. The optimization technique works to minimize voltage total harmonic distortions (VTHD) and current total harmonic distortions (ITHD), where maintaining a given power factor at a specified range is desired. According to the IEEE Standard 519, both indices are viewed as constraints for the optimal passive filter design problem. The performance of this technique will be discussed using numerical examples taken from previous publications.
Abstract: Ground Penetrating Radar (GPR) is one of the most effective electromagnetic techniques for non-destructive non-invasive subsurface features investigation. Water leak from pipelines is the most common undesirable reason of potable water losses. Rapid detection of such losses is going to enhance the use of the Water Distribution Networks (WDN) and decrease threatens associated with water mains leaks. In this study, GPR approach was developed to detect leaks by implementing an appropriate imaging analyzing strategy based on image refinement, reflection polarity and reflection amplitude that would ease the process of interpreting the collected raw radargram image.
Abstract: In the last decades, an increasing set of companies adopted lean philosophy to improve their productivity and efficiency promoting the so-called continuous improvement concept, reducing waste of time and cutting off no-value added activities. In parallel, increasing attention rises toward green practice and management through the spread of the green supply chain pattern, to minimise landfilled waste, drained wastewater and pollutant emissions. Starting from a review on contributions deepening lean and green principles applied to supply chain management, the most relevant drivers to measure the performance of industrial processes are pointed out. Specific attention is paid on the role of cost because it is of key importance and it crosses both lean and green principles. This analysis leads to figure out an original reference framework for integrating lean and green principles in designing and managing supply chains. The proposed framework supports the application, to the whole value chain or to parts of it, e.g. distribution network, assembly system, job-shop, storage system etc., of the lean-green integrated perspective. Evidences show that the combination of the lean and green practices lead to great results, higher than the sum of the performances from their separate application. Lean thinking has beneficial effects on green practices and, at the same time, methods allowing environmental savings generate positive effects on time reduction and process quality increase.
Abstract: This paper aims to investigate and emphasize the importance of the grid-connected photovoltaic (PV) systems regarding the intermittent nature of renewable generation, and the characterization of PV generation with regard to grid code compliance. The development of Photovoltaic systems and expansion plans relating to the futuristic in worldwide is elaborated. The most important impacts of grid connected photovoltaic systems on distribution networks as well as the Penetration level of PV system was investigated.
Abstract: In recent years, new techniques for solving complex
problems in engineering are proposed. One of these techniques is
JPSO algorithm. With innovative changes in the nature of the jump
algorithm JPSO, it is possible to construct a graph-based solution
with a new algorithm called G-JPSO. In this paper, a new algorithm
to solve the optimal control problem Fletcher-Powell and optimal
control of pumps in water distribution network was evaluated.
Optimal control of pumps comprise of optimum timetable operation
(status on and off) for each of the pumps at the desired time interval.
Maximum number of status on and off for each pumps imposed to the
objective function as another constraint. To determine the optimal
operation of pumps, a model-based optimization-simulation
algorithm was developed based on G-JPSO and JPSO algorithms.
The proposed algorithm results were compared well with the ant
colony algorithm, genetic and JPSO results. This shows the
robustness of proposed algorithm in finding near optimum solutions
with reasonable computational cost.
Abstract: This paper proposes a novel heuristic algorithm that aims to determine the best size and location of distributed generators in unbalanced distribution networks. The proposed heuristic algorithm can deal with the planning cases where power loss is to be optimized without violating the system practical constraints. The distributed generation units in the proposed algorithm is modeled as voltage controlled node with the flexibility to be converted to constant power factor node in case of reactive power limit violation. The proposed algorithm is implemented in MATLAB and tested on the IEEE 37 -node feeder. The results obtained show the effectiveness of the proposed algorithm.
Abstract: Carefully scheduling the operations of pumps can be
resulted to significant energy savings. Schedules can be defined
either implicit, in terms of other elements of the network such as tank
levels, or explicit by specifying the time during which each pump is
on/off. In this study, two new explicit representations based on timecontrolled
triggers were analyzed, where the maximum number of
pump switches was established beforehand, and the schedule may
contain fewer switches than the maximum. The optimal operation of
pumping stations was determined using a Jumping Particle Swarm
Optimization (JPSO) algorithm to achieve the minimum energy cost.
The model integrates JPSO optimizer and EPANET hydraulic
network solver. The optimal pump operation schedule of VanZyl
water distribution system was determined using the proposed model
and compared with those from Genetic and Ant Colony algorithms.
The results indicate that the proposed model utilizing the JPSO
algorithm is a versatile management model for the operation of realworld
water distribution system.
Abstract: This paper presents a novel algorithm for modeling
photovoltaic based distributed generators for the purpose of optimal
planning of distribution networks. The proposed algorithm utilizes
sequential Monte Carlo method in order to accurately consider the
stochastic nature of photovoltaic based distributed generators. The
proposed algorithm is implemented in MATLAB environment and
the results obtained are presented and discussed.
Abstract: The recent interest in alternative and renewable
energy systems results in increased installed capacity ratio of such
systems in total energy production of the world. Specifically, Wind
Energy Conversion Systems (WECS) draw significant attention
among possible alternative energy options, recently. On the contrary
of the positive points of penetrating WECS in all over the world in
terms of environment protection, energy independence of the
countries, etc., there are significant problems to be solved for the grid
connection of large scale WECS. The reactive power regulation,
voltage variation suppression, etc. can be presented as major issues to
be considered in this regard. Thus, this paper evaluates the
application of a Static VAr Compensator (SVC) unit for the reactive
power regulation and operation continuity of WECS during a fault
condition. The system is modeled employing the IEEE 13 node test
system. Thus, it is possible to evaluate the system performance with
an overall grid simulation model close to real grid systems. The
overall simulation model is developed in
MATLAB/Simulink/SimPowerSystems® environments and the
obtained results effectively match the target of the provided study.
Abstract: This paper proposes a novel heuristic algorithm that aims to determine the best size and location of distributed generators in unbalanced distribution networks. The proposed heuristic algorithm can deal with the planning cases where power loss is to be optimized without violating the system practical constraints. The distributed generation units in the proposed algorithm is modeled as voltage controlled node with the flexibility to be converted to constant power factor node in case of reactive power limit violation. The proposed algorithm is implemented in MATLAB and tested on the IEEE 37 -node feeder. The results obtained show the effectiveness of the proposed algorithm.
Abstract: One of the key aspects of power quality improvement
in power system is the mitigation of voltage sags/swells and flicker.
Custom power devices have been known as the best tools for voltage
disturbances mitigation as well as reactive power compensation.
Dynamic Voltage Restorer (DVR) which is the most efficient and
effective modern custom power device can provide the most
commercial solution to solve several problems of power quality in
distribution networks. This paper deals with analysis and simulation
technique of DVR based on instantaneous power theory which is a
quick control to detect signals. The main purpose of this work is to
remove three important disturbances including voltage sags/swells
and flicker. Simulation of the proposed method was carried out on
two sample systems by using Matlab software environment and the
results of simulation show that the proposed method is able to
provide desirable power quality in the presence of wide range of
disturbances.
Abstract: The following article presents Technology Centre of
Ostrava (TCO) in the Czech Republic describing the structure and
main research areas realized by the project ENET - Energy Units for
Utilization of non Traditional Energy Sources. More details are
presented from the research program dealing with transformation,
accumulation and distribution of electric energy. Technology Centre
has its own energy mix consisting of alternative sources of fuel
sources that use of process gases from the storage part and also the
energy from distribution network. The article will be focus on the
properties and application possibilities SiC semiconductor devices for
power semiconductor converter for photovoltaic systems.
Abstract: In this paper static scheme of under-frequency based load shedding is considered for chemical and petrochemical industries with islanded distribution networks relying heavily on the primary commodity to ensure minimum production loss, plant downtime or critical equipment shutdown. A simplistic methodology is proposed for in-house implementation of this scheme using underfrequency relays and a step by step guide is provided including the techniques to calculate maximum percentage overloads, frequency decay rates, time based frequency response and frequency based time response of the system. Case study of FFL electrical system is utilized, presenting the actual system parameters and employed load shedding settings following the similar series of steps. The arbitrary settings are then verified for worst overload conditions (loss of a generation source in this case) and comprehensive system response is then investigated.
Abstract: The distribution networks are often exposed to harmful
incidents which can halt the electricity supply of the customer. In this
context, we studied a real case of a critical zone of the Tunisian
network which is currently characterized by the dysfunction of its
plan of protection. In this paper, we were interested in the
harmonization of the protection plan settings in order to ensure a
perfect selectivity and a better continuity of service on the whole of
the network.
Abstract: Distributed Generation (DG) can help in reducing the
cost of electricity to the costumer, relieve network congestion and
provide environmentally friendly energy close to load centers. Its
capacity is also scalable and it provides voltage support at distribution
level. Hence, DG placement and penetration level is an important
problem for both the utility and DG owner. DG allocation and capacity
determination is a nonlinear optimization problem. The objective
function of this problem is the minimization of the total loss of the
distribution system. Also high levels of penetration of DG are a new
challenge for traditional electric power systems. This paper presents a
new methodology for the optimal placement of DG and penetration
level of DG in distribution system based on General Algebraic
Modeling System (GAMS) and Genetic Algorithm (GA).
Abstract: Researches and concerns in power quality gained
significant momentum in the field of power electronics systems over
the last two decades globally. This sudden increase in the number of
concerns over power quality problems is a result of the huge increase
in the use of non-linear loads. In this paper, power quality evaluation
of some distribution networks at Misurata - Libya has been done
using a power quality and energy analyzer (Fluke 437 Series II). The
results of this evaluation are used to minimize the problems of power
quality. The analysis shows the main power quality problems that
exist and the level of awareness of power quality issues with the aim
of generating a start point which can be used as guidelines for
researchers and end users in the field of power systems.
Abstract: Generally, distributed generation units refer to small-scale electric power generators that produce electricity at a site close to the customer or an electric distribution system (in parallel mode). From the customers’ point of view, a potentially lower cost, higher service reliability, high power quality, increased energy efficiency, and energy independence can be the key points of a proper DG unit. Moreover, the use of renewable types of distributed generations such as wind, photovoltaic, geothermal or hydroelectric power can also provide significant environmental benefits. Therefore, it is of crucial importance to study their impacts on the distribution networks. A marked increase in Distributed Generation (DG), associated with medium voltage distribution networks, may be expected. Nowadays, distribution networks are planned for unidirectional power flows that are peculiar to passive systems, and voltage control is carried out exclusively by varying the tap position of the HV/MV transformer. This paper will compare different DG control methods and possible network reconfiguration aimed at assessing their effect on voltage profiles.
Abstract: This paper investigates the effect of simultaneous placement of DGs and smart meters (SMs), on voltage profile improvement in active distribution networks (ADNs). A substantial center of attention has recently been on responsive loads initiated in power system problem studies such as distributed generations (DGs). Existence of responsive loads in active distribution networks (ADNs) would have undeniable effect on sizing and siting of DGs. For this reason, an optimal framework is proposed for sizing and siting of DGs and SMs in ADNs. SMs are taken into consideration for the sake of successful implementing of demand response programs (DRPs) such as direct load control (DLC) with end-side consumers. Looking for voltage profile improvement, the optimization procedure is solved by genetic algorithm (GA) and tested on IEEE 33-bus distribution test system. Different scenarios with variations in the number of DG units, individual or simultaneous placing of DGs and SMs, and adaptive power factor (APF) mode for DGs to support reactive power have been established. The obtained results confirm the significant effect of DRPs and APF mode in determining the optimal size and site of DGs to be connected in ADN resulting to the improvement of voltage profile as well.
Abstract: The increasing penetration of Distributed Generation and storage connected to the distribution network via PWM converters increases the possibility of a DC-component (offset) in voltage or current flowing into the grid. This occurs when even harmonics are present in the network voltage. DC-components can affect the operation and safety of several grid components. Therefore, an investigation of the way they are produced is important in order to take appropriate measures for their elimination. Further research on DC-components that appear on output voltage of converters is performed for different parameters of PWM technique and characteristics of even harmonics.