Abstract: In a wind power generator using doubly fed induction
generator (DFIG), the three-phase pulse width modulation (PWM)
voltage source converter (VSC) is used as grid side converter (GSC)
and rotor side converter (RSC). The standard linear control laws
proposed for GSC provides not only instablity against comparatively
large-signal disturbances, but also the problem of stability due to
uncertainty of load and variations in parameters. In this paper, a
nonlinear controller is designed for grid side converter (GSC) of a
DFIG for wind power application. The nonlinear controller is
designed based on the input-output feedback linearization control
method. The resulting closed-loop system ensures a sufficient
stability region, make robust to variations in circuit parameters and
also exhibits good transient response. Computer simulations and
experimental results are presented to confirm the effectiveness of the
proposed control strategy.
Abstract: This paper proposes the study of a robust control of
the doubly fed induction generator (DFIG) used in a wind energy
production. The proposed control is based on the linear active
disturbance rejection control (ADRC) and it is applied to the control
currents rotor of the DFIG, the DC bus voltage and active and
reactive power exchanged between the DFIG and the network. The
system under study and the proposed control are simulated using
MATLAB/SIMULINK.
Abstract: This paper presents the study of a variable speed wind
energy conversion system based on a Doubly Fed Induction Generator
(DFIG) based on a sliding mode control applied to achieve control of
active and reactive powers exchanged between the stator of the DFIG
and the grid to ensure a Maximum Power Point Tracking (MPPT) of
a wind energy conversion system. The proposed control algorithm is
applied to a DFIG whose stator is directly connected to the grid and
the rotor is connected to the PWM converter. To extract a maximum
of power, the rotor side converter is controlled by using a stator
flux-oriented strategy. The created decoupling control between active
and reactive stator power allows keeping the power factor close to
unity. Simulation results show that the wind turbine can operate at
its optimum energy for a wide range of wind speed.
Abstract: The impact of fixed speed squirrel cage type as well as
variable speed doubly fed induction generators (DFIG) on dynamic
performance of a multimachine power system has been investigated.
Detailed models of the various components have been presented and
the integration of asynchronous and synchronous generators has been
carried out through a rotor angle based transform. Simulation studies
carried out considering the conventional dynamic model of squirrel
cage asynchronous generators show that integration, as such, could
degrade to the AC system performance transiently. This article
proposes a frequency or power controller which can effectively
control the transients and restore normal operation of fixed speed
induction generator quickly. Comparison of simulation results
between classical cage and doubly-fed induction generators indicate
that the doubly fed induction machine is more adaptable to
multimachine AC system. Frequency controller installed in the DFIG
system can also improve its transient profile.
Abstract: This paper focuses on PSS/E modeling of wind farms
of Doubly-fed Induction Generator (DFIG) type and their impact on
issues of power system operation. Since Wind Turbine Generators
(WTG) don-t have the same characteristics as synchronous
generators, the appropriate modeling of wind farms is essential for
transmission system operators to analyze the best options of
transmission grid reinforcements as well as to evaluate the wind
power impact on reliability and security of supply. With the high
excepted penetration of wind power into the power system a
simultaneous loss of Wind Farm generation will put at risk power
system security and reliability. Therefore, the main wind grid code
requirements concern the fault ride through capability and frequency
operation range of wind turbines. In case of grid faults wind turbines
have to supply a definite reactive power depending on the
instantaneous voltage and to return quickly to normal operation.
Abstract: During recent years wind turbine technology has
undergone rapid developments. Growth in size and the optimization
of wind turbines has enabled wind energy to become increasingly
competitive with conventional energy sources. As a result today-s
wind turbines participate actively in the power production of several
countries around the world. These developments raise a number of
challenges to be dealt with now and in the future. The penetration of
wind energy in the grid raises questions about the compatibility of the
wind turbine power production with the grid. In particular, the
contribution to grid stability, power quality and behavior during fault
situations plays therefore as important a role as the reliability. In the
present work, we addressed two fault situations that have shown their
influence on the generator and the behavior of the wind over the
defects which are briefly discussed based on simulation results.