Abstract: This study was carried out experimentally and analytically about the performance of solar cell panel system for operating the pump coupled by dc-motor. The solar cell panel with total area 1.9848 m2 consists of three modules of 80 Wp each. The small centrifugal pump powered by dc-motor is operated to lift water from 1m to 7m heads in sequence and gives the amount of water pumped over the whole day from 08.00 to 16.00 h are 11988, 10851, 8874, 7695, 5760, 3600, 2340 L/d respectively. The hourly global solar radiation during the day is an average of 506 W/m2. This study also presents the I-V characteristics of the panel at global radiations 200, 400, 600, 800 and 1000 W/m2 matched with the operation of the pump at the above lifting heads. It proves that the only solar radiations 800 and 1000 W/m2 could provide lifting head from 1m to 7m. The analysis shows the best efficiency point of the performance of solar cell panel system occurs at the pumping head 2.89 m.
Abstract: In this paper, we present an experimental testing for
a new algorithm that determines an optimal controller-s coefficients
for output variance reduction related to Linear Time Invariant (LTI)
Systems. The algorithm features simplicity in calculation, generalization
to minimal and non-minimal phase systems, and could be
configured to achieve reference tracking as well as variance reduction
after compromising with the output variance. An experiment of DCmotor
velocity control demonstrates the application of this new
algorithm in designing the controller. The results show that the
controller achieves minimum variance and reference tracking for a
preset velocity reference relying on an identified model of the motor.