Abstract: The objective of this study is to conduct computational
fluid dynamic (CFD) simulations for evaluating the cooling efficacy
from vegetation implanted in a public park in the Taipei, Taiwan. To
probe the impacts of park renewal by means of adding three pavilions
and supplementary green areas on urban microclimates, the simulated
results have revealed that the park having a higher percentage of green
coverage ratio (GCR) tended to experience a better cooling effect.
These findings can be used to explore the effects of different greening
modifications on urban environments for achieving an effective
thermal comfort in urban public spaces.
Abstract: Many water desalination technologies have been
developed but in general they are energy intensive and have high cost
and adverse environmental impact. Recently, adsorption technology
for water desalination has been investigated showing the potential of
using low temperature waste heat (50-85oC) thus reducing energy
consumption and CO2 emissions. This work mathematically
compares the performance of an adsorption cycle that produces two
useful effects namely, fresh water and cooling using two different
adsorbents, silica-gel and an advanced zeolite material AQSOA-ZO2,
produced by Mitsubishi plastics. It was found that at low chilled
water temperatures, typically below 20oC, the AQSOA-Z02 is more
efficient than silica-gel as the cycle can produce 5.8 m3 of fresh water
per day and 50.1 Rton of cooling per tonne of AQSOA-ZO2. Above
20oC silica-gel is still better as the cycle production reaches 8.4 m3
per day and 62.4 Rton per tonne of silica-gel. These results show the
potential of using the AQSOA-Z02 at low chilled water temperature
for water desalination and cooling applications.
Abstract: Press-hardened profiles are used e.g. for automotive
applications in order to improve light weight construction due to the
high reachable strength. The application of interior water-air spray
cooling contributes to significantly reducing the cycle time in the
production of heat-treated tubes. This paper describes a new
manufacturing method for producing press-hardened hollow profiles
by means of an additional interior cooling based on a water-air spray.
Furthermore, this paper provides the results of thorough
investigations on the properties of press-hardened tubes in
dependence of varying spray parameters.
Abstract: In this study, ultrasonic assisted machining (UAM) technique is applied in side-surface milling experiment for glass-ceramic workpiece material. The tungsten carbide cutting-tool with diamond coating is used in conjunction with two kinds of cooling/lubrication mediums such as water-soluble (WS) cutting fluid and minimum quantity lubricant (MQL). Full factorial process parameter combinations on the milling experiments are planned to investigate the effect of process parameters on cutting performance. From the experimental results, it tries to search for the better process parameter combination which the edge-indentation and the surface roughness are acceptable. In the machining experiments, ultrasonic oscillator was used to excite a cutting-tool along the radial direction producing a very small amplitude of vibration frequency of 20KHz to assist the machining process. After processing, toolmaker microscope was used to detect the side-surface morphology, edge-indentation and cutting tool wear under different combination of cutting parameters, and analysis and discussion were also conducted for experimental results. The results show that the main leading parameters to edge-indentation of glass ceramic are cutting depth and feed rate. In order to reduce edge-indentation, it needs to use lower cutting depth and feed rate. Water-soluble cutting fluid provides a better cooling effect in the primary cutting area; it may effectively reduce the edge-indentation and improve the surface morphology of the glass ceramic. The use of ultrasonic assisted technique can effectively enhance the surface finish cleanness and reduce cutting tool wear and edge-indentation.
Abstract: This paper deals with the theoretical and numerical
investigation of magneto hydrodynamic boundary layer flow of a
nanofluid past a wedge shaped wick in heat pipe used for the cooling
of electronic components and different type of machines. To
incorporate the effect of nanoparticle diameter, concentration of
nanoparticles in the pure fluid, nanothermal layer formed around the
nanoparticle and Brownian motion of nanoparticles etc., appropriate
models are used for the effective thermal and physical properties of
nanofluids. To model the rotation of nanoparticles inside the base
fluid, microfluidics theory is used. In this investigation ethylene
glycol (EG) based nanofluids, are taken into account. The non-linear
equations governing the flow and heat transfer are solved by using a
very effective particle swarm optimization technique along with
Runge-Kutta method. The values of heat transfer coefficient are
found for different parameters involved in the formulation viz.
nanoparticle concentration, nanoparticle size, magnetic field and
wedge angle etc. It is found that, the wedge angle, presence of
magnetic field, nanoparticle size and nanoparticle concentration etc.
have prominent effects on fluid flow and heat transfer characteristics
for the considered configuration.
Abstract: Significant quota of Municipal Electrical Energy
consumption is related to Decentralized Air Conditioning which is
mostly provided by evaporative coolers. So the aim is to optimize
design of air conditioners to increase their efficiencies. To achieve
this goal, results of practical standardized tests for 40 evaporative
coolers in different types collected and simultaneously results for
same coolers based on one of EER (Energy Efficiency Ratio)
modeling styles are figured out. By comparing experimental results
of different coolers standardized tests with modeling results,
preciseness of used model is assessed and after comparing gained
preciseness with international standards based on EER for cooling
capacity, aeration, and also electrical energy consumption, energy
label from A (most effective) to G (less effective) is classified; finally
needed methods to optimize energy consumption and coolers’
classification are provided.
Abstract: In this paper, we introduced a gradient-based inverse
solver to obtain the missing boundary conditions based on the
readings of internal thermocouples. The results show that the method
is very sensitive to measurement errors, and becomes unstable when
small time steps are used. The artificial neural networks are shown to
be capable of capturing the whole thermal history on the run-out
table, but are not very effective in restoring the detailed behavior of
the boundary conditions. Also, they behave poorly in nonlinear cases
and where the boundary condition profile is different.
GA and PSO are more effective in finding a detailed
representation of the time-varying boundary conditions, as well as in
nonlinear cases. However, their convergence takes longer. A
variation of the basic PSO, called CRPSO, showed the best
performance among the three versions. Also, PSO proved to be
effective in handling noisy data, especially when its performance
parameters were tuned. An increase in the self-confidence parameter
was also found to be effective, as it increased the global search
capabilities of the algorithm. RPSO was the most effective variation
in dealing with noise, closely followed by CRPSO. The latter
variation is recommended for inverse heat conduction problems, as it
combines the efficiency and effectiveness required by these
problems.
Abstract: Co-crystal is believed to improve the solubility and
dissolution rates and thus, enhanced the bioavailability of poor water
soluble drugs particularly during the oral route of administration.
With the existing of poorly soluble drugs in pharmaceutical industry,
the screening of co-crystal formation using carbamazepine (CBZ) as
a model drug compound with dicarboxylic acids co-crystal formers
(CCF) namely fumaric (FA) and succinic (SA) acids in ethanol has
been studied. The co-crystal formations were studied by varying the
mol ratio values of CCF to CBZ to access the effect of CCF
concentration on the formation of the co-crystal. Solvent evaporation,
slurry and cooling crystallization which representing the solution
based method co-crystal screening were used. Based on the
differential scanning calorimetry (DSC) analysis, the melting point of
CBZ-SA in different ratio was in the range between 188oC-189oC.
For CBZ-FA form A and CBZ-FA form B the melting point in
different ratio were in the range of 174oC-175oC and 185oC-186oC
respectively. The product crystal from the screening was also
characterized using X-ray powder diffraction (XRPD). The XRPD
pattern profile analysis has shown that the CBZ co-crystals with FA
and SA were successfully formed for all ratios studied. The findings
revealed that CBZ-FA co-crystal were formed in two different
polymorphs. It was found that CBZ-FA form A and form B were
formed from evaporation and slurry crystallization methods
respectively. On the other hand, in cooling crystallization method,
CBZ-FA form A was formed at lower mol ratio of CCF to CBZ and
vice versa. This study disclosed that different methods and mol ratios
during the co-crystal screening can affect the outcome of co-crystal
produced such as polymorphic forms of co-crystal and thereof. Thus,
it was suggested that careful attentions is needed during the screening
since the co-crystal formation is currently one of the promising
approach to be considered in research and development for
pharmaceutical industry to improve the poorly soluble drugs.
Abstract: A three-dimensional numerical model of
thermoelectric generator (TEG) modules attached to a large chimney
plate is proposed and solved numerically using a control volume based
finite difference formulation. The TEG module consists of a
thermoelectric generator, an elliptical pin-fin heat sink, and a cold
plate for water cooling. In the chimney, the temperature of flue gases is
450-650K. Although the TEG hot-side temperature and thus the
electric power output can be increased by inserting an elliptical pin-fin
heat sink into the chimney tunnel to increase the heat transfer area, the
pin fin heat sink would cause extra pumping power at the same time.
The main purpose of this study is to analyze the effects of geometrical
parameters on the electric power output and chimney pressure drop
characteristics. The effects of different operating conditions, including
various inlet velocities (Vin= 1, 3, 5 m/s), inlet temperatures (Tgas = 450,
550, 650K) and different fin height (0 to 150 mm) are discussed in
detail. The predicted numerical data for the power vs. current (P-I)
curve are in good agreement (within 11%) with the experimental data.
Abstract: Parabolic solar trough systems have seen limited
deployments in cold northern climates as they are more suitable for
electricity production in southern latitudes. A numerical dynamic
model is developed to simulate troughs installed in cold climates and
validated using a parabolic solar trough facility in Winnipeg. The
model is developed in Simulink and will be utilized to simulate a trigeneration
system for heating, cooling and electricity generation in
remote northern communities. The main objective of this simulation
is to obtain operational data of solar troughs in cold climates and use
the model to determine ways to improve the economics and address
cold weather issues.
In this paper the validated Simulink model is applied to simulate a
solar assisted absorption cooling system along with electricity
generation using Organic Rankine Cycle (ORC) and thermal storage.
A control strategy is employed to distribute the heated oil from solar
collectors among the above three systems considering the
temperature requirements. This modelling provides dynamic
performance results using measured meteorological data recorded
every minute at the solar facility location. The purpose of this
modeling approach is to accurately predict system performance at
each time step considering the solar radiation fluctuations due to
passing clouds. Optimization of the controller in cold temperatures is
another goal of the simulation to for example minimize heat losses in
winter when energy demand is high and solar resources are low.
The solar absorption cooling is modeled to use the generated heat
from the solar trough system and provide cooling in summer for a
greenhouse which is located next to the solar field.
The results of the simulation are presented for a summer day in
Winnipeg which includes comparison of performance parameters of
the absorption cooling and ORC systems at different heat transfer
fluid (HTF) temperatures.
Abstract: In this study, the Compressive strength of concretes
made with Ground Granulated Blast furnace Slag (GGBS),
Pulverised Fuel Ash (PFA), Rice Husk Ash (RHA) and Waste Glass
Powder (WGP) after they were exposed 7800C (exposure duration of
around 60 minutes) and then allowed to cool down gradually in the
furnace for about 280 minutes at water binder ratio of 0.50 was
investigated. GGBS, PFA, RHA and WGP were used to replace up to
20% Portland cement in the control concrete. Test for the
determination of workability, compressive strength and tensile
splitting strength of the concretes were carried out and the results
were compared with control concrete. The test results showed that the
compressive strength decreased by an average of around 30% after
the concretes were exposed to the heating and cooling scenario.
Abstract: The building sector is responsible, in many
industrialized countries, for about 40% of the total energy
requirements, so it seems necessary to devote some efforts in this
area in order to achieve a significant reduction of energy
consumption and of greenhouse gases emissions.
The paper presents a study aiming at providing a design
methodology able to identify the best configuration of the system
building/plant, from a technical, economic and environmentally point
of view.
Normally, the classical approach involves a building's energy
loads analysis under steady state conditions, and subsequent selection
of measures aimed at improving the energy performance, based on
previous experience made by architects and engineers in the design
team. Instead, the proposed approach uses a sequence of two wellknown
scientifically validated calculation methods (TRNSYS and
RETScreen), that allow quite a detailed feasibility analysis.
To assess the validity of the calculation model, an existing,
historical building in Central Italy, that will be the object of
restoration and preservative redevelopment, was selected as a casestudy.
The building is made of a basement and three floors, with a
total floor area of about 3,000 square meters.
The first step has been the determination of the heating and
cooling energy loads of the building in a dynamic regime by means,
which allows simulating the real energy needs of the building in
function of its use. Traditional methodologies, based as they are on
steady-state conditions, cannot faithfully reproduce the effects of
varying climatic conditions and of inertial properties of the structure.
With this model is possible to obtain quite accurate and reliable
results that allow identifying effective combinations building-HVAC
system.
The second step has consisted of using output data obtained as
input to the calculation model, which enables to compare different
system configurations from the energy, environmental and financial
point of view, with an analysis of investment, and operation and
maintenance costs, so allowing determining the economic benefit of
possible interventions.
The classical methodology often leads to the choice of
conventional plant systems, while our calculation model provides a
financial-economic assessment for innovative energy systems and
low environmental impact.
Computational analysis can help in the design phase, particularly
in the case of complex structures with centralized plant systems, by
comparing the data returned by the calculation model for different
design options.
Abstract: The thermal behavior of a large-scale, phase change material (PCM) enhanced building envelope system was studied in regard to the need for pre-fabricated construction in subtropical regions. The proposed large-scale envelope consists of a reinforced aluminum skin, insulation core, phase change material and reinforced gypsum board. The PCM impact on an energy efficiency of an enveloped room was resolved by validation of the EnergyPlus numerical scheme and optimization of a smart material location in the core. The PCM location was optimized by a minimization method of a cooling energy demand. It has been shown that there is good agreement between the test and simulation results. The optimal location of the PCM layer in Hong Kong summer conditions has been then recomputed for core thicknesses of 40, 60 and 80 mm. A non-dimensional value of the optimal PCM location was obtained to be same for all the studied cases and the considered external and internal conditions.
Abstract: Meeting the growth in demand for digital services
such as social media, telecommunications, and business and cloud
services requires large scale data centres, which has led to an increase
in their end use energy demand. Generally, over 30% of data centre
power is consumed by the necessary cooling overhead. Thus energy
can be reduced by improving the cooling efficiency. Air and liquid
can both be used as cooling media for the data centre. Traditional
data centre cooling systems use air, however liquid is recognised as a
promising method that can handle the more densely packed data
centres. Liquid cooling can be classified into three methods; rack heat
exchanger, on-chip heat exchanger and full immersion of the
microelectronics. This study quantifies the improvements of heat
transfer specifically for the case of immersed microelectronics by
varying the CPU and heat sink location. Immersion of the server is
achieved by filling the gap between the microelectronics and a water
jacket with a dielectric liquid which convects the heat from the CPU
to the water jacket on the opposite side. Heat transfer is governed by
two physical mechanisms, which is natural convection for the fixed
enclosure filled with dielectric liquid and forced convection for the
water that is pumped through the water jacket. The model in this
study is validated with published numerical and experimental work
and shows good agreement with previous work. The results show that
the heat transfer performance and Nusselt number (Nu) is improved
by 89% by placing the CPU and heat sink on the bottom of the
microelectronics enclosure.
Abstract: This paper outlines the basic installation and operation of magnetic inductive flow velocity sensors on large underground cooling water pipelines. Research on the effects of cathodic protection as well as into other factors that might influence the overall performance of the meter is presented in this paper. The experiments were carried out on an immersion type magnetic meter specially used for flow measurement of cooling water pipeline. An attempt has been made in this paper to outline guidelines that can ensure accurate measurement related to immersion type magnetic meters on underground pipelines.
Abstract: Micro-alloyed steel components are used in
automotive industry for the necessity to make the manufacturing
process cycles shorter when compared to conventional steel by
eliminating heat treatment cycles, so an important saving of costs and
energy can be reached by reducing the number of operations. Microalloying
elements like vanadium, niobium or titanium have been
added to medium carbon steels to achieve grain refinement with or
without precipitation strengthening along with uniform
microstructure throughout the matrix. Present study reports the
applicability of medium carbon vanadium micro-alloyed steel in hot
forging. Forgeability has been determined with respect to different
cooling rates, after forging in a hydraulic press at 50% diameter
reduction in temperature range of 900-11000C. Final microstructures,
hardness, tensile strength, and impact strength have been evaluated.
The friction coefficients of different lubricating conditions, viz.,
graphite in hydraulic oil, graphite in furnace oil, DF 150 (Graphite,
Water-Based) die lubricant and dry or without any lubrication were
obtained from the ring compression test for the above micro-alloyed
steel. Results of ring compression tests indicate that graphite in
hydraulic oil lubricant is preferred for free forging and dry lubricant
is preferred for die forging operation. Exceptionally good forgeability
and high resistance to fracture, especially for faster cooling rate has
been observed for fine equiaxed ferrite-pearlite grains, some amount
of bainite and fine precipitates of vanadium carbides and
carbonitrides. The results indicated that the cooling rate has a
remarkable effect on the microstructure and mechanical properties at
room temperature.
Abstract: Cement concrete is a complex mixture of different
materials. Behaviour of concrete depends on its mix proportions and
constituents when it is subjected to elevated temperatures. Principal
effects due to elevated temperatures are loss in compressive strength,
loss in weight or mass, change in colour and spall of concrete. The
experimental results of normal concrete and high strength concrete
subjected elevated temperatures at 200°C, 400°C, 600°C, and 800°C
and different cooling regimes viz. air cooling, water quenching on
different grade of concrete are reported in this paper.
Abstract: A numerical study of natural convection heat transfer
in water filled cavity has been examined in 3-Dfor single phase liquid
cooling system by using an array of parallel plate fins mounted to one
wall of a cavity. The heat generated by a heat source represents a
computer CPU with dimensions of 37.5∗37.5mm mounted on
substrate. A cold plate is used as a heat sink installed on the opposite
vertical end of the enclosure. The air flow inside the computer case is
created by an exhaust fan. A turbulent air flow is assumed and k-ε
model is applied. The fins are installed on the substrate to enhance
the heat transfer. The applied power energy range used is between 15
- 40W. In order to determine the thermal behaviour of the cooling
system, the effect of the heat input and the number of the parallel
plate fins are investigated. The results illustrate that as the fin number
increases the maximum heat source temperature decreases. However,
when the fin number increases to critical value the temperature start
to increase due to the fins are too closely spaced and that cause the
obstruction of water flow. The introduction of parallel plate fins
reduces the maximum heat source temperature by 10% compared to
the case without fins. The cooling system maintains the maximum
chip temperature at 64.68°C when the heat input was at 40W that is
much lower than the recommended computer chips limit temperature
of no more than 85°C and hence the performance of the CPU is
enhanced.
Abstract: A thermosyphon system is a heat transfer loop which
operates on the basis of gravity and buoyancy forces. It guarantees a
good reliability and low maintenance cost as it does not involve any
mechanical pump. Therefore, it can be used in many industrial
applications such as refrigeration and air conditioning, electronic
cooling, nuclear reactors, geothermal heat extraction, etc. But flow
instabilities and loop configuration are the major problems in this
system. Several previous researchers studied that stabilities can be
suppressed by using nanofluids as loop fluid. In the present study a
rectangular thermosyphon loop with end heat exchangers are
considered for the study. This configuration is more appropriate for
many practical applications such as solar water heater, geothermal
heat extraction, etc. In the present work, steady-state analysis is
carried out on thermosyphon loop with parallel flow coaxial heat
exchangers at heat source and heat sink. In this loop nanofluid is
considered as the loop fluid and water is considered as the external
fluid in both hot and cold heat exchangers. For this analysis onedimensional
homogeneous model is developed. In this model,
conservation equations like conservation of mass, momentum, energy
are discretized using finite difference method. A computer code is
written in MATLAB to simulate the flow in thermosyphon loop. A
comparison in terms of heat transfer is made between water and
nanofluid as working fluids in the loop.
Abstract: Auckland has a temperate climate with comfortable warm, dry summers and mild, wet winters. An Auckland school normally does not need air conditioning for cooling during the summer and only needs heating during the winter. The Auckland school building thermal design should more focus on winter thermal performance and indoor thermal comfort for energy efficiency. This field study of testing indoor and outdoor air temperatures, relative humidity and indoor surface temperatures of three classrooms with different envelopes were carried out in the Avondale College during the winter months in 2013. According to the field study data, this study is to compare and evaluate winter thermal performance and indoor thermal conditions of school buildings with different envelopes.