Abstract: In this paper, an artificial neural network simulator is
employed to carry out diagnosis and prognosis on electric motor as
rotating machinery based on predictive maintenance. Vibration data
of the primary failed motor including unbalance, misalignment and
bearing fault were collected for training the neural network. Neural
network training was performed for a variety of inputs and the motor
condition was used as the expert training information. The main
purpose of applying the neural network as an expert system was to
detect the type of failure and applying preventive maintenance. The
advantage of this study is for machinery Industries by providing
appropriate maintenance that has an essential activity to keep the
production process going at all processes in the machinery industry.
Proper maintenance is pivotal in order to prevent the possible failures
in operating system and increase the availability and effectiveness of
a system by analyzing vibration monitoring and developing expert
system.
Abstract: Power cables are vulnerable to failure due to aging or
defects that occur with the passage of time under continuous
operation and loading stresses. PD detection and characterization
provide information on the location, nature, form and extent of the
degradation. As a result, PD monitoring has become an important
part of condition based maintenance (CBM) program among power
utilities. Online partial discharge (PD) localization of defect sources
in power cable system is possible using the time of flight method.
The information regarding the time difference between the main and
reflected pulses and cable length can help in locating the partial
discharge source along the cable length. However, if the length of
the cable is not known and the defect source is located at the extreme
ends of the cable or in the middle of the cable, then double ended
measurement is required to indicate the location of PD source. Use of
multiple sensors can also help in discriminating the cable PD or local/
external PD. This paper presents the experience and results from
online partial discharge measurements conducted in the laboratory
and the challenges in partial discharge source localization.