Abstract: In this paper, a new cooling system using a nacelle duct
is proposed for the mechanical room in the household refrigerator. The
conventional mechanical room consists of a condenser, a compressor
and an axial fan. The axial fan is mainly responsible for cooling the
condenser and the compressor. The new cooling system is developed
by replacing the axial fan with the nacelle duct including the small
centrifugal fan. The parametric study is carried out to find the optimum
designs of the nacelle duct in terms of performance and efficiency.
Through this study, it is revealed that the new system can reduce the
space, electrical power and noise compared with the conventional
system
Abstract: Generally flow behavior in centrifugal fan is observed
to be in a state of instability with flow separation zones on suction
surface as well as near the front shroud. Overall performance of the
diffusion process in a centrifugal fan could be enhanced by
judiciously introducing the boundary layer suction slots. With easy
accessibility of CFD as an analytical tool, an extensive numerical
whole field analysis of the effect of boundary layer suction slots in
discrete regions of suspected separation points is possible. This paper
attempts to explore the effect of boundary layer suction slots
corresponding to various geometrical locations on the impeller with
converging configurations for the slots. The analysis shows that the
converging suction slots located on the impeller blade about 25%
from the trailing edge, significantly improves the static pressure
recovery across the fan. Also it is found that Slots provided at a
radial distance of about 12% from the leading and trailing edges
marginally improve the static pressure recovery across the fan.
Abstract: This study experimentally and numerically investigates
motor cooling performance. The motor consists of a centrifugal fan,
two axial fans, a shaft, a stator, a rotor and a heat exchanger with 637
cooling tubes. The pressure rise-flow rate (P-Q) performance curves of
the cooling fans at 1800 rpm are tested using a test apparatus
complying with the Chinese National Standard (CNS) 2726.
Compared with the experimental measurements, the numerical
analysis results show that the P-Q performance curves of the axial fan
and centrifugal fan can be estimated within about 2% and 6%,
respectively. By using the simplified model, setting up the heat
exchanger and stator as porous media, the flow field in the motor is
calculated. By using the results of the flow field near the rotor and
stator, and subjecting the heat generation rate as a boundary condition,
the temperature distributions of the stator and rotor are also calculated.
The simulation results show that the calculated temperature of the
stator winding near the axial fans is lower by about 5% than the
measured value, and the calculated temperature of the stator core
located at the center of the stator is about 1% higher than the measured
value. Besides, discussion is made to improve the motor cooling
performance.
Abstract: A simple mobile engine-driven pneumatic paddy
collector made of locally available materials using local
manufacturing technology was designed, fabricated, and tested for
collecting and bagging of paddy dried on concrete pavement. The
pneumatic paddy collector had the following major components:
radial flat bladed type centrifugal fan, power transmission system,
bagging area, frame and the conveyance system. Results showed
significant differences on the collecting capacity, noise level, and fuel
consumption when rotational speed of the air mover shaft was varied.
Other parameters such as collecting efficiency, air velocity,
augmented cracked grain percentage, and germination rate were not
significantly affected by varying rotational speed of the air mover
shaft. The pneumatic paddy collector had a collecting efficiency of
99.33 % with a collecting capacity of 2685.00 kg/h at maximum
rotational speed of centrifugal fan shaft of about 4200 rpm. The
machine entailed an investment cost of P 62,829.25. The break-even
weight of paddy was 510,606.75 kg/yr at a collecting cost of 0.11
P/kg of paddy. Utilizing the machine for 400 hours per year
generated an income of P 23,887.73. The projected time needed to
recover cost of the machine based on 2685 kg/h collecting capacity
was 2.63 year.
Abstract: The flow field in a centrifugal fan is highly complex
with flow reversal taking place on the suction side of impeller and
diffuser vanes. Generally performance of the centrifugal fan could be
enhanced by judiciously introducing splitter vanes so as to improve
the diffusion process. An extensive numerical whole field analysis on
the effect of splitter vanes placed in discrete regions of suspected
separation points is possible using CFD. This paper examines the
effect of splitter vanes corresponding to various geometrical
locations on the impeller and diffuser. The analysis shows that the
splitter vanes located near the diffuser exit improves the static
pressure recovery across the diffusing domain to a larger extent. Also
it is found that splitter vanes located at the impeller trailing edge and
diffuser leading edge at the mid-span of the circumferential distance
between the blades show a marginal improvement in the static
pressure recovery across the fan. However, splitters provided near to
the suction side of the impeller trailing edge (25% of the
circumferential gap between the impeller blades towards the suction
side), adversely affect the static pressure recovery of the fan.