Abstract: For the efficient and safe use of the cable-stayed
bridge, a design based on the detailed local analysis of the cable anchor
system is required. Also, a theoretical design process for the anchor
system should be prepared and reviewed. Generally, the size of the
fixing pipe in the anchor system is decided according to the
specifications prepared by cable-manufacturing companies, and
accordingly, there is difficulty determining the initial inner diameters
of the fixing pipes. As such, there is no choice but to use the products
with the existing sizes. In this study, the existing design process of the
fixing pipe, is a type of guide pipe anchor in the cable anchor system,
is reviewed, a formula determining the thickness of the fixing pipe is
proposed, and the convenience and validity of the suggested equation
is compared with the results of the existing designs to verify its
convenience and validity.