Abstract: Traditionally, the embodied energy of design choices
which reduce operational energy were assumed to have a negligible
impact on the life cycle energy of buildings. However with new
buildings having considerably lower operational energy, the
significance of embodied energy increases. A life cycle assessment of
a population of house designs was conducted in a mild and mixed
climate zone. It was determined not only that embodied energy
dominates life cycle energy, but that the impact on embodied of
design choices was of equal significance to the impact on operational
energy.