Abstract: In the past decade, with the rapid development of China's economy, the purchasing power and physical demand of residents have been improved, which results in the vast emergence of public buildings like large shopping malls. However, the architects usually focus on the internal functions and streamlines of these buildings, ignoring the impact of the environment on the subjective feelings of building users. Only in Zhejiang province, the infiltration of cold air in winter frequently occurs at the entrance of sizeable commercial complex buildings that have been in operation, which will affect the environmental comfort of the building lobby and internal public spaces. At present, to reduce these adverse effects, it is usually adopted to add active equipment, such as setting air curtains to block air exchange or adding heating air conditioners. From the perspective of energy consumption, the infiltration of cold air into the entrance will increase the heat consumption of indoor heating equipment, which will indirectly cause considerable economic losses during the whole winter heating stage. Therefore, it is of considerable significance to explore the suitable entrance forms for improving the environmental comfort of commercial buildings and saving energy. In this paper, a commercial complex with apparent cold air infiltration problem in Hangzhou is selected as the research object to establish a model. The environmental parameters of the building entrance, including temperature, wind speed, and infiltration air volume, are obtained by Computational Fluid Dynamics (CFD) simulation, from which the heat consumption caused by the natural air infiltration in the winter and its potential economic loss is estimated as the objective metric. This study finally obtains the optimization direction of the building entrance form of the commercial complex by comparing the simulation results of other local commercial complex projects with different entrance forms. The conclusions will guide the entrance design of the same type of commercial complex in this area.
Abstract: An analysis of the air tightness level is performed on a representative sample of school classrooms in Southern Spain, which allows knowing the infiltration level of these classrooms, mainly through its envelope, which can affect both energy demand and occupant's thermal comfort. By using a pressurization/depressurization equipment (Blower-Door test), a characterization of 45 multipurpose classrooms have been performed in nine non-university educational institutions of the main climate zones of Southern Spain. In spite of having two doors and a high ratio between glass surface and outer surface, it is possible to see in these classrooms that there is an adequate level of airtightness, since all the n50 values obtained are lower than 9.0 ACH, with an average value around 7.0 ACH.
Abstract: Air infiltration in mass scale industrial applications of
bio char production is inevitable. The presence of oxygen during the
carbonization process is detrimental to the production of biochar yield
and properties. The experiment was carried out on several wood
species in a fixed-bed pyrolyser under various fractions of oxygen
ranging from 0% to 11% by varying nitrogen and oxygen composition
in the pyrolysing gas mixtures at desired compositions. The bed
temperature and holding time were also varied. Process optimization
was carried out by Response Surface Methodology (RSM) by
employing Central Composite Design (CCD) using Design Expert 6.0
Software. The effect of oxygen ratio and holding time on biochar yield
within the range studied were statistically significant. From the
analysis result, optimum condition of 15.2% biochar yield of
mangrove wood was predicted at pyrolysis temperature of 403 oC,
oxygen percentage of 2.3% and holding time of two hours. This
prediction agreed well with the experiment finding of 15.1% biochar
yield.