Abstract: Radiant chilled ceiling (RCC) has been perceived to save more energy and provide better thermal comfort than the traditional air conditioning system. However, its application has been rather limited by some reasons e.g., the scarce information about the thermal characteristic in the radiant room and the local climate influence on the system performance, etc. To bridge such gap, an office-like experiment room with a RCC was constructed in the hot and humid climate of Thailand. This paper presents exemplarily results from the RCC experiments to give an insight into the thermal environment in a radiant room and the cooling load associated to maintain the room's comfort condition. It gave a demonstration of the RCC system operation for its application to achieve thermal comfort in offices in a hot humid climate, as well.
Abstract: This paper deals the energy saving performance of GHP (Gas engine heat pump) air conditioning system has improved with time-series variation. There are two types of air conditioning systems, VRF (Variable refrigerant flow) and central cooling and heating system. VRF is classified as EHP (Electric driven heat pump) and GHP. EHP drives the compressor with electric motor. GHP drives the compressor with the gas engine. The electric consumption of GHP is less than one tenth of EHP does.
In this study, the energy consumption data of GHP installed the junior high schools was collected. An annual and monthly energy consumption per rated thermal output power of each apparatus was calculated, and then their energy efficiency was analyzed. From these data, we investigated improvement of the energy saving of the GHP air conditioning system by the change in the generation.
Abstract: The objective of this study is to present the test
results of variable air volume (VAV) air conditioning system
optimized by two objective genetic algorithm (GA). The objective
functions are energy savings and thermal comfort. The optimal set
points for fuzzy logic controller (FLC) are the supply air temperature
(Ts), the supply duct static pressure (Ps), the chilled water
temperature (Tw), and zone temperature (Tz) that is taken as the
problem variables. Supply airflow rate and chilled water flow rate are
considered to be the constraints. The optimal set point values are
obtained from GA process and assigned into fuzzy logic controller
(FLC) in order to conserve energy and maintain thermal comfort in
real time VAV air conditioning system. A VAV air conditioning
system with FLC installed in a software laboratory has been taken for
the purpose of energy analysis. The total energy saving obtained in
VAV GA optimization system with FLC compared with constant air
volume (CAV) system is expected to achieve 31.5%. The optimal
duct static pressure obtained through Genetic fuzzy methodology
attributes to better air distribution by delivering the optimal quantity
of supply air to the conditioned space. This combination enhanced
the advantages of uniform air distribution, thermal comfort and
improved energy savings potential.