Abstract: The present paper attempts to investigate the
prediction of air entrainment rate and aeration efficiency of a free
overfall jets issuing from a triangular sharp crested weir by using
regression based modelling. The empirical equations, Support vector
machine (polynomial and radial basis function) models and the linear
regression techniques were applied on the triangular sharp crested
weirs relating the air entrainment rate and the aeration efficiency to
the input parameters namely drop height, discharge, and vertex angle.
It was observed that there exists a good agreement between the
measured values and the values obtained using empirical equations,
Support vector machine (Polynomial and rbf) models and the linear
regression techniques. The test results demonstrated that the SVM
based (Poly & rbf) model also provided acceptable prediction of the
measured values with reasonable accuracy along with empirical
equations and linear regression techniques in modelling the air
entrainment rate and the aeration efficiency of a free overfall jets
issuing from triangular sharp crested weir. Further sensitivity analysis
has also been performed to study the impact of input parameter on the
output in terms of air entrainment rate and aeration efficiency.
Abstract: This paper examines the use of mechanical aerator for
oxidation-ditch process. The rotor, which controls the aeration, is the
main component of the aeration process. Therefore, the objective of
this study is to find out the variations in overall oxygen transfer
coefficient (KLa) and aeration efficiency (AE) for different
configurations of aerator by varying the parameters viz. speed of
aerator, depth of immersion, blade tip angles so as to yield higher
values of KLa and AE. Six different configurations of aerator were
developed and fabricated in the laboratory and were tested for abovementioned
parameters. The curved blade rotor (CBR) emerged as a
potential aerator with blade tip angle of 47°.
The mathematical models are developed for predicting the
behaviour of CBR w.r.t kLa and power. In laboratory studies, the
optimum value of KLa and AE were observed to be 10.33 h-1 and
2.269 kg O2/ kWh.