Abstract: Fault-proneness of a software module is the
probability that the module contains faults. A correlation exists
between the fault-proneness of the software and the measurable
attributes of the code (i.e. the static metrics) and of the testing (i.e.
the dynamic metrics). Early detection of fault-prone software
components enables verification experts to concentrate their time and
resources on the problem areas of the software system under
development. This paper introduces Genetic Algorithm based
software fault prediction models with Object-Oriented metrics. The
contribution of this paper is that it has used Metric values of JEdit
open source software for generation of the rules for the classification
of software modules in the categories of Faulty and non faulty
modules and thereafter empirically validation is performed. The
results shows that Genetic algorithm approach can be used for
finding the fault proneness in object oriented software components.
Abstract: This paper presents an adaptive nonlinear position
controller with velocity constraint, capable of combining the
input-output linearization technique and Lyapunov stability theory.
Based on the Lyapunov stability theory, the adaptation law of the
proposed controller is derived along with the verification of the overall
system-s stability. Computer simulation results demonstrate that the
proposed controller is robust and it can ensure transient stability of
BLDCM, under the occurrence of a large sudden fault.
Abstract: In rotating machinery one of the critical components
that is prone to premature failure is the rolling bearing.
Consequently, early warning of an imminent bearing failure is much
critical to the safety and reliability of any high speed rotating
machines. This study is concerned with the application of Recurrence
Quantification Analysis (RQA) in fault detection of rolling element
bearings in rotating machinery. Based on the results from this study it
is reported that the RQA variable, percent determinism, is sensitive
to the type of fault investigated and therefore can provide useful
information on bearing damage in rolling element bearings.
Abstract: Contractor selection in Saudi Arabia is very important due to the large construction boom and the contractor role to get over construction risks. The need for investigating contractor selection is due to the following reasons; large number of defaulted or failed projects (18%), large number of disputes attributed to contractor during the project execution stage (almost twofold), the extension of the General Agreement on Tariffs and Trade (GATT) into construction industry, and finally the few number of researches. The selection strategy is not perfect and considered as the reason behind irresponsible contractors. As a response, this research was conducted to review the contractor selection strategies as an integral part of a long advanced research to develop a good selection model. Many techniques can be used to form a selection strategy; multi criteria for optimizing decision, prequalification to discover contractor-s responsibility, bidding process for competition, third party guarantee to enhance the selection, and fuzzy techniques for ambiguities and incomplete information.
Abstract: Software maintenance is extremely important activity in software development life cycle. It involves a lot of human efforts, cost and time. Software maintenance may be further subdivided into different activities such as fault prediction, fault detection, fault prevention, fault correction etc. This topic has gained substantial attention due to sophisticated and complex applications, commercial hardware, clustered architecture and artificial intelligence. In this paper we surveyed the work done in the field of software maintenance. Software fault prediction has been studied in context of fault prone modules, self healing systems, developer information, maintenance models etc. Still a lot of things like modeling and weightage of impact of different kind of faults in the various types of software systems need to be explored in the field of fault severity.
Abstract: This paper presents a Neural Network (NN) identification of icing parameters in an A340 aircraft and a reconfiguration technique to keep the A/C performance close to the performance prior to icing. Five aircraft parameters are assumed to be considerably affected by icing. The off-line training for identifying the clear and iced dynamics is based on the Levenberg-Marquard Backpropagation algorithm. The icing parameters are located in the system matrix. The physical locations of the icing are assumed at the right and left wings. The reconfiguration is based on the technique known as the control mixer approach or pseudo inverse technique. This technique generates the new control input vector such that the A/C dynamics is not much affected by icing. In the simulations, the longitudinal and lateral dynamics of an Airbus A340 aircraft model are considered, and the stability derivatives affected by icing are identified. The simulation results show the successful NN identification of the icing parameters and the reconfigured flight dynamics having the similar performance before the icing. In other words, the destabilizing icing affect is compensated.
Abstract: Back-to-back static synchronous compensator (BtBSTATCOM) consists of two back-to-back voltage-source converters (VSC) with a common DC link in a substation. This configuration extends the capabilities of conventional STATCOM that bidirectional active power transfer from one bus to another is possible. In this paper, VSCs are designed in quasi multi-pulse form in which GTOs are triggered only once per cycle in PSCAD/EMTDC. The design details of VSCs as well as gate switching circuits and controllers are fully represented. Regulation modes of BtBSTATCOM are verified and tested on a multi-machine power system through different simulation cases. The results presented in the form of typical time responses show that practical PI controllers are almost robust and stable in case of start-up, set-point change, and line faults.
Abstract: The purpose of the present study is the calculation of Gutenber-Richter parameters (a, b) and analyze the mean annual rate of exceedance of earthquake magnitude (Om ) of southern segment of the Sagaing fault and its associate components. The study area is situated about 200 km radius centered at Yangon. Earthquake data file is using from 1975 to 2006 August 31. The bounded Gutenberg- Richter recurrence law for 0 M is 4.0 and max M is 7.5.
Abstract: The purpose of this paper is to investigate the
influence of a number of variables on the conditional mean and
conditional variance of credit spread changes. The empirical analysis
in this paper is conducted within the context of bivariate GARCH-in-
Mean models, using the so-called BEKK parameterization. We show
that credit spread changes are determined by interest-rate and equityreturn
variables, which is in line with theory as provided by the
structural models of default. We also identify the credit spread
change volatility as an important determinant of credit spread
changes, and provide evidence on the transmission of volatility
between the variables under study.
Abstract: This paper proposes method of diagnosing ball screw
preload loss through the Hilbert-Huang Transform (HHT) and
Multiscale entropy (MSE) process. The proposed method can
diagnose ball screw preload loss through vibration signals when the
machine tool is in operation. Maximum dynamic preload of 2 %, 4 %,
and 6 % ball screws were predesigned, manufactured, and tested
experimentally. Signal patterns are discussed and revealed using
Empirical Mode Decomposition(EMD)with the Hilbert Spectrum.
Different preload features are extracted and discriminated using HHT.
The irregularity development of a ball screw with preload loss is
determined and abstracted using MSE based on complexity
perception. Experiment results show that the proposed method can
predict the status of ball screw preload loss. Smart sensing for the
health of the ball screw is also possible based on a comparative
evaluation of MSE by the signal processing and pattern matching of
EMD/HHT. This diagnosis method realizes the purposes of prognostic
effectiveness on knowing the preload loss and utilizing convenience.
Abstract: Among various testing methodologies, Built-in Self-
Test (BIST) is recognized as a low cost, effective paradigm. Also,
full adders are one of the basic building blocks of most arithmetic
circuits in all processing units. In this paper, an optimized testable 2-
bit full adder as a test building block is proposed. Then, a BIST
procedure is introduced to scale up the building block and to generate
a self testable n-bit full adders. The target design can achieve 100%
fault coverage using insignificant amount of hardware redundancy.
Moreover, Overall test time is reduced by utilizing polymorphic
gates and also by testing full adder building blocks in parallel.
Abstract: Pyritisation halos are identified in weathering crusts and unconsolidated formations at five locations within large fault structure of the Urals’ eastern slope. Electron microscopy reveals the presence of inclusions and growths on pyrite faces – normally on cubic pyrite with striations, or combinations of cubes and other forms. Following neogenesis types are established: native elements and intermetallic compounds (including gold and silver), halogenides, sulphides, sulfosalts, tellurides, sulphotellurides,
selenides, tungstates, sulphates, phosphates, carbon-based substances. Direct relationship is noted between amount and diversity of such mineral phases, and proximity to and scale of ore-grade mineralization. Gold and silver, both in native form and within tellurides, presence of lead (galena, native lead), native tungsten, and, possibly, molybdenite and sulfosalts can indicate gold-bearing formations. First find of native tungsten in the Urals is for the first time – in crystallised and druse-like form. Link is suggested between unusual mineralization and “reducing” hydrothermal fluids from deep-seated faults at later stages of Urals’ reactivation.
Abstract: In the self-stabilizing algorithmic paradigm, each node has a local view of the system, in a finite amount of time the system converges to a global state with desired property. In a graph G =
(V, E), a subset S C V is a 2-packing if Vi c V: IN[i] n SI
Abstract: Diagnostic goal of transformers in service is to detect the winding or the core in fault. Transformers are valuable equipment which makes a major contribution to the supply security of a power system. Consequently, it is of great importance to minimize the frequency and duration of unwanted outages of power transformers. So, Frequency Response Analysis (FRA) is found to be a useful tool for reliable detection of incipient mechanical fault in a transformer, by finding winding or core defects. The authors propose as first part of this article, the coupled circuits method, because, it gives most possible exhaustive modelling of transformers. And as second part of this work, the application of FRA in low frequency in order to improve and simplify the response reading. This study can be useful as a base data for the other transformers of the same categories intended for distribution grid.
Abstract: The High Voltage (HV) transmission mains into the community necessitate earthing design to ensure safety compliance of the system. Concrete poles are widely used within HV transmission mains; which could have an impact on the earth grid impedance and input impedance of the system from the fault point of view. This paper provides information on concrete pole earthing to enhance the split factor of the system; further, it discusses the deployment of concrete structures in high soil resistivity area to reduce the earth grid system of the plant. This paper introduces the cut off soil resistivity SC ρ when replacing timber poles with concrete ones.
Abstract: The electric power industry is currently undergoing an unprecedented reform. One of the most exciting and potentially profitable recent developments is increasing usage of artificial intelligence techniques. The intention of this paper is to give an overview of using neural network (NN) techniques in power systems. According to the growth rate of NNs application in some power system subjects, this paper introduce a brief overview in fault diagnosis, security assessment, load forecasting, economic dispatch and harmonic analyzing. Advantages and disadvantages of using NNs in above mentioned subjects and the main challenges in these fields have been explained, too.
Abstract: Personnel protection devices are cardinal in safety hazard applications. They are widely used in home, office and in industry environments to reduce the risk of lethal shock to human being and equipment safety. This paper briefly reviews various personnel protection devices also describes the basic working principle of conventional ground fault circuit interrupter (GFCI) or ground fault isolator (GFI), its disadvantages and ways to overcome the disadvantages with solid-state relay (SSR) based GFI with ultrafast response up on fault implemented in printed circuit board. This solid state GFI comprises discrete MOSFET based alternating current (AC) switches, linear optical amplifier, photovoltaic isolator and sense resistor. In conventional GFI, current transformer is employed as a sensing element to detect the difference in current flow between live and neutral conductor. If there is no fault in equipment powered through GFI, due to insulation failure of internal wires and windings of motors, both live and neutral currents will be equal in magnitude and opposite in phase.
Abstract: The research study was based on an evaluation of the
ability of glued test samples to pass the criterion of sufficient
bondline adhesion under the exposure conditions defined in EN 302-
1. Additionally, an infrared spectroscopic analysis of the evaluated
adhesives (phenol-resorcinol-formaldehyde PRF and melamine-ureaformaldehyde
MUF) with different mix ratios was carried out to
evaluate the possible effects of a faulty technological process.
Abstract: The protection of parallel transmission lines has been a challenging task due to mutual coupling between the adjacent circuits of the line. This paper presents a novel scheme for detection and classification of faults on parallel transmission lines. The proposed approach uses combination of wavelet transform and neural network, to solve the problem. While wavelet transform is a powerful mathematical tool which can be employed as a fast and very effective means of analyzing power system transient signals, artificial neural network has a ability to classify non-linear relationship between measured signals by identifying different patterns of the associated signals. The proposed algorithm consists of time-frequency analysis of fault generated transients using wavelet transform, followed by pattern recognition using artificial neural network to identify the type of the fault. MATLAB/Simulink is used to generate fault signals and verify the correctness of the algorithm. The adaptive discrimination scheme is tested by simulating different types of fault and varying fault resistance, fault location and fault inception time, on a given power system model. The simulation results show that the proposed scheme for fault diagnosis is able to classify all the faults on the parallel transmission line rapidly and correctly.
Abstract: management of medical devices in hospitals includes
the planning of medical equipment acquisition and maintenance. The
presence of critical and non-critical areas together with technological
proliferation render the management of medical devices very
complex. This study creates an easy and objective methodology for
the analysis of medical equipment maintenance, that makes the
management of medical devices more feasible. The study has been
carried out at Florence Hospital Careggi and it aims to help the
clinical engineering department to manage medical equipment by
clarifying the hospital situation through a characterization of the
different areas, technologies and fault typologies.