Abstract: Rice husk is one of the alternative fuels for Thailand because of its high potential and environmental benefits. Nonetheless, the environmental profile of the electricity production from rice husk must be assessed to ensure reduced environmental damage. A 10 MW pilot plant using rice husk as feedstock is the study site. The environmental impacts from rice husk power plant are evaluated by using the Life Cycle Assessment (LCA) methodology. Energy, material and carbon balances have been determined for tracing the system flow. Carbon closure has been used for describing of the net amount of CO2 released from the system in relation to the amount being recycled between the power plant and the CO2 adsorbed by rice husk. The transportation of rice husk to the power plant has significant on global warming, but not on acidification and photo-oxidant formation. The results showed that the impact potentials from rice husk power plant are lesser than the conventional plants for most of the categories considered; except the photo-oxidant formation potential from CO. The high CO from rice husk power plant may be due to low boiler efficiency and high moisture content in rice husk. The performance of the study site can be enhanced by improving the combustion efficiency.
Abstract: This paper reviews designs of the built environment
from a sustainability perspective, emphasizing their importance in
achieving ecological and sustainable economic objectives. The built
environment has traditionally resulted in loss of biodiversity,
extinction of some species, climate change, excessive water use, land
degradation, space depletion, waste accumulation, energy
consumption and environmental pollution. Materials used like
plastics, metals, bricks, concrete, cement, natural aggregates, glass
and plaster have wreaked havoc on the earth´s resources, since they
have high levels of embodied energy hence not sustainable.
Additional resources are consumed during use and disposal phases.
Proposed designs for sustainability solutions include: ecological
sanitation and eco-efficiency systems that ensure social, economic,
environmental and technical sustainability. Renewable materials and
energy systems, passive cooling and heating systems and material
and energy reduction, reuse and recycling can improve the sector.
These ideas are intended to inform the field of ecological design of
the built environment.
Abstract: It is suggested to evaluate environmental performance
of energy sector using Data Envelopment Analysis with nondiscretionary
factors (DEA-ND) with relative indicators as inputs and
outputs. The latter allows for comparison of the objects essentially
different in size. Inclusion of non-discretionary factors serves
separation of the indicators that are beyond the control of the objects.
A virtual perfect object comprised of maximal outputs and minimal
inputs was added to the group of actual ones. In this setting, explicit
solution of the DEA-ND problem was obtained. Energy sector of the
United States was analyzed using suggested approach for the period
of 1980 – 2006 with expected values of economic indicators for 2030
used for forming the perfect object. It was obtained that
environmental performance has been increasing steadily for the
period from 7.7% through 50.0% but still remains well below the
prospected level
Abstract: The Long-range Energy and Alternatives Planning (LEAP) energy planning system has been developed for South Africa, for the 2005 base year and a limited number of plausible future scenarios that may have significant implications (negative or positive) in terms of environmental impacts. The system quantifies the national energy demand for the domestic, commercial, transport, industry and agriculture sectors, the supply of electricity and liquid fuels, and the resulting emissions. The South African National Energy Research Institute (SANERI) identified the need to develop an environmental assessment tool, based on the LEAP energy planning system, to provide decision-makers and stakeholders with the necessary understanding of the environmental impacts associated with different energy scenarios. A comprehensive analysis of indicators that are used internationally and in South Africa was done and the available data was accessed to select a reasonable number of indicators that could be utilized in energy planning. A consultative process was followed to determine the needs of different stakeholders on the required indicators and also the most suitable form of reporting. This paper demonstrates the application of Energy Environmental Sustainability Indicators (EESIs) as part of the developed tool, which assists with the identification of the environmental consequences of energy generation and use scenarios and thereby promotes sustainability, since environmental considerations can then be integrated into the preparation and adoption of policies, plans, programs and projects. Recommendations are made to refine the tool further for South Africa.
Abstract: In this paper, in order to investigate the effects of
photovoltaic system introduction to detached houses in Japan, two
kinds of works were done. Firstly, the hourly generation amount of a
4.2kW photovoltaic system were simulated in 46 cities to investigate
the potential of the system in different regions in Japan using a
simulation model of photovoltaic system. Secondly, based on the
simulated electricity generation amount, the energy saving, the
environmental and the economic effect of the photovoltaic system
were examined from hourly to annual timescales, based upon
calculations of typical electricity, heating, cooling and hot water
supply load profiles for Japanese dwellings. The above analysis was
carried out using a standard year-s hourly weather data for the
different city provided by the Expanded AMeDAS Weather Data
issued by AIJ (Architectural Institute of Japan).
Abstract: This paper investigates the application of large scale (LS-PV) two-axis tracking photovoltaic power plant in Al-Jagbob, Libya. A 50MW PV-grid connected (two-axis tracking) power plant design in Al-Jagbob, Libya has been carried out presently. A hetero-junction with intrinsic thin layer (HIT) type PV module has been selected and modeled. A Microsoft Excel-VBA program has been constructed to compute slope radiation, dew-point, sky temperature, and then cell temperature, maximum power output and module efficiency for this system, for tracking system. The results for energy production show that the total energy output is 128.5 GWh/year. The average module efficiency is 16.6%. The electricity generation capacity factor (CF) and solar capacity factor (SCF) were found to be 29.3% and 70.4% respectively. A 50MW two axis tracking power plant with a total energy output of 128.5 GWh/year would reduce CO2 pollution by 85,581 tonnes of each year. The payback time for the proposed LS-PV photovoltaic power plant was found to be 4 years.
Abstract: The aim of this paper is to examine the relationship among CO2 per capita emissions, energy consumption, economic growth and bilateral trade between Singapore and Malaysia for the 1970-2011 period. ARDL model and Granger causality tests are employed for the analysis. Results of bound F-statistics suggest that long-run relationship exists between CO2 per capita (PCO2) and its determinants. The EKC hypothesis is not supported in Malaysia. Carbon emissions are mainly determined by energy consumption in the short and long run. While, exports to Singapore is a significant variable in explaining PCO2 emissions in Malaysia in long-run. Furthermore, we find a unidirectional causal relationship running from economic growth to PCO2 emissions.
Abstract: In maize growing technologies, tillage technological operations are the most time-consuming and require the greatest fuel input. Substitution of conventional tillage, involving deep ploughing, by other reduced tillage methods can reduce technological production costs, diminish soil degradation and environmental pollution from greenhouse gas emissions, as well as improve economic competitiveness of agricultural produce.
Experiments designed to assess energy and environmental aspects associated with different reduced tillage systems, applied in maize cultivation were conducted at Aleksandras Stulginskis University taking into account Lithuania’s economic and climate conditions. The study involved 5 tillage treatments: deep ploughing (DP, control), shallow ploughing (SP), deep cultivation (DC), shallow cultivation (SC) and no-tillage (NT).
Our experimental evidence suggests that with the application of reduced tillage systems it is feasible to reduce fuel consumption by 13-58% and working time input by 8.4% to nearly 3-fold, to reduce the cost price of maize cultivation technological operations, decrease environmental pollution with CO2 gas by 30 to 146 kg ha-1, compared with the deep ploughing.
Abstract: The scope of this paper is to evaluate and compare the potential of LS-PV(Large Scale Photovoltaic Power Plant) power generation systems in the southern region of Libya at Al-Kufra for both stationary and tracking systems. A Microsoft Excel-VBA program has been developed to compute slope radiation, dew-point, sky temperature, and then cell temperature, maximum power output and module efficiency of the system for stationary system and for tracking system. The results for energy production show that the total energy output is 114GWh/year for stationary system and 148GWh/year for tracking system. The average module efficiency for the stationary system is 16.6% and 16.2% for the tracking system.
The values of electricity generation capacity factor (CF) and solar capacity factor (SCF) for stationary system were found to be 26% and 62.5% respectively and 34% and 82% for tracking system. The GCR (Ground Cover Ratio) for a stationary system is 0.7, which corresponds to a tilt angle of 24°. The GCR for tracking system was found to be 0.12. The estimated ground area needed to build a 50MW PV plant amounts to approx. 0.55km2 for a stationary PV field constituted by HIT PV arrays and approx. 91MW/ km2. In case of a tracker PV field, the required ground area amounts approx.2.4km2 and approx. 20.5MW/ km2.
Abstract: A cleaner production project was implemented in a
bakery. The project is based on the substitution of the best available
technique for an obsolete leaven production technology. The new
technology enables production of durable, high-quality leavens.
Moreover, 25% of flour as the original raw material can be replaced
by pastry from the previous day production which has not been sold.
That pastry was previously disposed in a waste incineration plant.
Besides the environmental benefits resulting from less waste, lower
consumption of energy, reduction of sewage waters quantity and
floury dustiness there are also significant economic benefits. Payback
period of investment was calculated with help of static method of
financial analysis about 2.6 years, using dynamic method 3.5 years
and an internal rate of return more than 29%. The supposed annual
average profit after taxationin the second year of operation was
incompliance with the real profit.
Abstract: This study addresses a concept of the Sustainable Building Environmental Model (SBEM) developed to optimize energy consumption in air conditioning and ventilation (ACV) systems without any deterioration of indoor environmental quality (IEQ). The SBEM incorporates two main components: an adaptive comfort temperature control module (ACT) and a new carbon dioxide demand control module (nDCV). These two modules take an innovative approach to maintain satisfaction of the Indoor Environmental Quality (IEQ) with optimum energy consumption; they provide a rational basis of effective control. A total of 2133 sets of measurement data of indoor air temperature (Ta), relative humidity (Rh) and carbon dioxide concentration (CO2) were conducted in some Hong Kong offices to investigate the potential of integrating the SBEM. A simulation was used to evaluate the dynamic performance of the energy and air conditioning system with the integration of the SBEM in an air-conditioned building. It allows us make a clear picture of the control strategies and performed any pre-tuned of controllers before utilized in real systems. With the integration of SBEM, it was able to save up to 12.3% in simulation of overall electricity consumption, and maintain the average carbon dioxide concentration within 1000ppm and occupant dissatisfaction in 20%.
Abstract: Residential buildings consume significant amounts of
energy and produce large amount of emissions and waste. However,
there is a substantial potential for energy savings in this sector which
needs to be evaluated over the life cycle of residential buildings. Life
Cycle Assessment (LCA) methodology has been employed to study
the primary energy uses and associated environmental impacts of
different phases (i.e., product, construction, use, end of life, and
beyond building life) for residential buildings. Four different
alternatives of residential buildings in Vancouver (BC, Canada) with
a 50-year lifespan have been evaluated, including High Rise
Apartment (HRA), Low Rise Apartment (LRA), Single family
Attached House (SAH), and Single family Detached House (SDH).
Life cycle performance of the buildings is evaluated for embodied
energy, embodied environmental impacts, operational energy,
operational environmental impacts, total life-cycle energy, and total
life cycle environmental impacts. Estimation of operational energy
and LCA are performed using DesignBuilder software and Athena
Impact estimator software respectively.
The study results revealed that over the life span of the buildings,
the relationship between the energy use and the environmental
impacts are identical. LRA is found to be the best alternative in terms
of embodied energy use and embodied environmental impacts; while,
HRA showed the best life-cycle performance in terms of minimum
energy use and environmental impacts. Sensitivity analysis has also
been carried out to study the influence of building service lifespan
over 50, 75, and 100 years on the relative significance of embodied
energy and total life cycle energy. The life-cycle energy requirements
for SDH are found to be a significant component among the four
types of residential buildings. The overall disclose that the primary
operations of these buildings accounts for 90% of the total life cycle
energy which far outweighs minor differences in embodied effects
between the buildings.
Abstract: Different countries have introduced different schemes
and policies to counter global warming. The rationale behind the
proposed policies and the potential barriers to successful
implementation of the policies adopted by the countries were
analyzed and estimated based on different models. It is argued that
these models enhance the transparency and provide a better
understanding to the policy makers. However, these models are
underpinned with several structural and baseline assumptions. These
assumptions, modeling features and future prediction of emission
reductions and other implication such as cost and benefits of a
transition to a low-carbon economy and its economy wide impacts
were discussed. On the other hand, there are potential barriers in the
form political, financial, and cultural and many others that pose a
threat to the mitigation options.
Abstract: This paper analyzes the Environmental Kuznets Curve (EKC) hypothesis to test the causality relationship between economic activity, trade openness and carbon dioxide emissions in Mexico (1971-2011). The results achieved in this research show that there are three long-run relationships between production, trade openness, energy consumption and carbon dioxide emissions. The EKC hypothesis was not verified in this research. Indeed, it was found evidence of a short-term unidirectional causality from GDP and GDP squared to carbon dioxide emissions, from GDP, GDP squared and TO to EC, and bidirectional causality between TO and GDP. Finally, it was found evidence of long-term unidirectional causality from all variables to carbon emissions. These results suggest that a reduction in energy consumption, economic activity, or an increase in trade openness would reduce pollution.
Abstract: This paper will explore the influence of energy sector in Arab Republic of Egypt which has shared its responsibilities of many environmental challenges as the second largest economy in the Middle East (after Iran). Air and water pollution, desertification, inadequate disposal of solid waste and damage to coral reefs are serious problems that influence environmental management in Egypt. The intensive reliance of high population density and strong industrial growth are wearing Egypt's resources, and the rapidly-growing population has forced Egypt to breakdown agricultural land to residential and relevant use of commercial ingestion. The depletion effects of natural resources impose the government to apply innovation techniques in emission control and focus on sustainability. The cogeneration will be presented to control thermal losses and increase efficiency of energy power system.
Abstract: This paper describes in details a commercial green building that has been designed and constructed in Marsa Matrouh, Egypt. The balance between homebuilding and the sustainable environment has been taken into consideration in the design and construction of this building. The building consists of one floor with 3 m height and 2810 m2 area while the envelope area is 1400 m2. The building construction fulfills the natural ventilation requirements. The glass curtain walls are about 50% of the building and the windows area is 300 m2. 6 mm greenish gray tinted temper glass as outer board lite, 6 mm safety glass as inner board lite and 16 mm thick dehydrated air spaces are used in the building. Visible light with 50% transmission, 0.26 solar factor, 0.67 shading coefficient and 1.3 W/m2.K thermal insulation U-value are implemented to realize the performance requirements. Optimum electrical distribution for lighting system, air conditions and other electrical loads has been carried out. Power and quantity of each type of the lighting system lamps and the energy consumption of the lighting system are investigated. The design of the air conditions system is based on summer and winter outdoor conditions. Ventilated, air conditioned spaces and fresh air rates are determined. Variable Refrigerant Flow (VRF) is the air conditioning system used in this building. The VRF outdoor units are located on the roof of the building and connected to indoor units through refrigerant piping. Indoor units are distributed in all building zones through ducts and air outlets to ensure efficient air distribution. The green building energy consumption is evaluated monthly all over one year and compared with the consumed energy in the non-green conditions using the Hourly Analysis Program (HAP) model. The comparison results show that the total energy consumed per year in the green building is about 1,103,221 kWh while the non-green energy consumption is about 1,692,057 kWh. In other words, the green building total annual energy cost is reduced from 136,581 $ to 89,051 $. This means that, the energy saving and consequently the money-saving of this green construction is about 35%. In addition, 13 points are awarded by applying one of the most popular worldwide green energy certification programs (Leadership in Energy and Environmental Design “LEED”) as a rating system for the green construction. It is concluded that this green building ensures sustainability, saves energy and offers an optimum energy performance with minimum cost.
Abstract: The rapidly diminishing fossil fuel reserves, their exorbitant cost and the increasingly apparent negative effect of fossil fuels to climate changes is a wake-up call to explore renewable energy. Wind, bio-fuel and solar power have already become staples of Kenyan electricity mix. The potential of electric power generation from marine tidal currents is enormous, with oceans covering more than 70% of the earth. However, attempts to harness marine tidal energy in Kenya, has yet to be studied thoroughly due to its promising, cyclic, reliable and predictable nature and the vast energy contained within it. The high load factors resulting from the fluid properties and the predictable resource characteristics make marine currents particularly attractive for power generation and advantageous when compared to others. Global-level resource assessments and oceanographic literature and data have been compiled in an analysis of the technology-specific requirements for tidal energy technologies and the physical resources. Temporal variations in resource intensity as well as the differences between small-scale applications are considered.
Abstract: The enhanced need for food items is receiving more importance due to a gradual increase in the world population and, in this scenario, fertilizers play a very important role in agriculture. In this study, the production of the normal superphosphate was investigated with a continuous chamber method by adding potassium chloride to a mixture of Hibin apatite and Kingisepp phosphorite. In the experiments, the following parameters were selected: The concentration of sulfuric acid (54–66% (w/w)), the stoichiometric norm of sulfuric acid (100, 107, 110, 114% (w/w)), the ratio of apatite/phosphorite in the mixture of phosphate (95/5, 90/10, 85/15, 80/20, 75/25, 70/30, 65/35,60/40, 55/45, 50/50 (w/w)), potassium chloride/the mixture of phosphate (1/50, 2/50, 3/50,4/50, 5/50 (w/w)), and the reaction time (2–8 min). It was observed that by adding potassium chloride to a low-grade phosphorite and using it to substitute a fraction of high-grade apatite in the normal superphosphate production not only resulted in a high-quality product but also eliminated the waiting period for the maturation of superphosphate in the storage. The objective of this study was to produce a normal superphosphate fertilizer by using a continuous chamber method in order to accelerate the production process and to reduce the environmental pollution caused by fluoride gases by eliminating the maturation time in the storage.
Abstract: Catalysts play an important role in producing valuable fuel products in petroleum refining; but, due to feedstock’s impurities catalyst gets deactivated with carbon and metal deposition. The disposal of spent catalyst falls under the category of hazardous industrial waste that requires strict agreement with environmental regulations. The spent hydroprocessing catalyst contains Mo, V and Ni at high concentrations that have been found to be economically significant for recovery. Metal recovery process includes deoiling, decoking, grinding, dissolving and treatment with complexing leaching agent such as ethylene diamine tetra acetic acid (EDTA). The process conditions have been optimized as a function of time, temperature and EDTA concentration in presence of ultrasonic agitation. The results indicated that optimum condition established through this approach could recover 97%, 94% and 95% of the extracted Mo, V and Ni, respectively, while 95% EDTA was recovered after acid treatment.
Abstract: For the past decades, CO2 flooding has been used as a successful method for enhanced oil recovery (EOR). However, high mobility ratio and fingering effect are considered as important drawbacka of this process. Low temperature injection of CO2 into high temperature reservoirs may improve the oil recovery, but simulating multiphase flow in the non-isothermal medium is difficult, and commercial simulators are very unstable in these conditions. Furthermore, to best of authors’ knowledge, no experimental work was done to verify the results of the simulations and to understand the pore-scale process. In this paper, we present results of investigations on injection of low temperature CO2 into a high-pressure high-temperature micromodel with injection temperature range from 34 to 75 °F. Effect of temperature and saturation changes of different fluids are measured in each case. The results prove the proposed method. The injection of CO2 at low temperatures increased the oil recovery in high temperature reservoirs significantly. Also, CO2 rich phases available in the high temperature system can affect the oil recovery through the better sweep of the oil which is initially caused by penetration of LCO2 inside the system. Furthermore, no unfavorable effect was detected using this method. Low temperature CO2 is proposed to be used as early as secondary recovery.