Abstract: An approach for experimental measurement of the
dynamic characteristics of linear electromagnet actuators is
presented. It uses accelerometer sensor to register the armature
acceleration. The velocity and displacement of the moving parts can
be obtained by integration of the acceleration results. The armature
movement of permanent magnet linear actuator is acquired using this
technique. The results are analyzed and the performance of the
supposed approach is compared with the most commonly used
experimental setup where the displacement of the armature vs. time
is measured instead of its acceleration.
Abstract: The dome with ribs and rings, which covers the
ROMEXPO pavilion from Bucharest, was designed after the collapse
of the single layer reticulated dome. In this paper, it was made the
checking of the structure, under the dynamic loads with three
recorded accelerograms calibrated according to Romanian seismic
design code P100-1/2006. Under the action the dynamic loadings, it
was made a time-history analysis to determine the zones where the
plastic hinges appear, at what accelerations and their position on the
structure. The studied dome is formed by 32 spatial semi arches and
three rings: one circular ring located at the top of the dome and
another two rings, design as trusses, the first near the supports and the
second as an intermediate rings above the skylights. Above the
skylights up to the top, the dome is tight together with purlins and
bracings.