Research on Axial End Flux Leakage and Detent Force of Transverse Flux PM Linear Machine

According to 3D magnetic circuit of the transverse flux PM linear machine, distribution law is presented, and analytical expression of axial end flux leakage is derived using numerical method. Maxwell stress tensor is used to solve detent force of mover. A 3D finite element model of the transverse flux PM machine is built to analyze the flux distribution and detent force. Experimental results of the prototype verified the validity of axial end flux leakage and detent force theoretical derivation, the research on axial end flux leakage and detent force provides a valuable reference to other types of linear machine.

Study on Guangzhou's Employment Subcentres and Polycentricity

Since the late 1980s, the new phenomena of 'employment subcentres' or 'polycentricity' has appeared in the metropolises of North American and Western Europe and it has been an interesting topic for academics and researchers. This paper specifically uses one case study-Guangzhou to explore the development and the mechanism of employment subcentres and polycentricity in Chinese metropolises by spatial analysis method on the basis of the first economic census data. In conclusion, the paper regards that the employment subcentres and polycentricity has existed in Chinese metropolises. And that, the mechanism of them is mainly from the secondary industry instead of the tertiary industry in North American and Western Europe

Study on Distortion of Bi-Steel Concrete Beam

As an economic and safe structure, Bi-steel is widely used in reinforced concrete with less consumption of steel. In this paper, III Bi-steel concrete beam has been analyzed. Through careful observation and theoretical analysis, the new calculating formulae for structural rigidity and crack have been formulated for this Bi-steel concrete beam. And structural rigidity and the crack features have also been theoretically analyzed.

Study of Base-Isolation Building System

In order to improve the effect of isolation structure, the principles and behaviours of the base-isolation system are studied, and the types and characteristics of the base-isolation are also discussed. Compared to the traditional aseismatic structures, the base isolation structures decrease the seismic response obviously: the total structural aseismatic value decreases to 1/4-1/32 and the seismic shear stress in the upper structure decreases to 1/14-1/23. In the huge seism, the structure can have an obvious aseismatic effect.