Abstract: Photovoltaic (PV) energy is one of the most important renewable energy sources. Maximum Power Point Tracking (MPPT) techniques should be used in photovoltaic systems to maximize the PV panel output power by tracking continuously the maximum power point which depends on panel’s temperature and on irradiance conditions. Incremental conductance control method has been used as MPPT algorithm. The methodology is based on connecting a pulse width modulated dc/dc SEPIC converter, which is controlled by a microprocessor based unit. The SEPIC converter is one of the buck-boost converters which maintain the output voltage as constant irrespective of the solar isolation level. By adjusting the switching frequency of the converter the maximum power point has been achieved. The main difference between the method used in the proposed MPPT systems and other technique used in the past is that PV array output power is used to directly control the dc/dc converter thus reducing the complexity of the system. The resulting system has high efficiency, low cost and can be easily modified. The tracking capability has been verified experimentally with a 10 W solar panel under a controlled experimental setup. The SEPIC converter and their control strategies has been analyzed and simulated using Simulink/Matlab software.
Abstract: The paper presents an on-line recognition machine
(RM) for continuous/isolated, dynamic and static gestures that arise
in Flight Deck Officer (FDO) training. RM is based on generic pattern
recognition framework. Gestures are represented as templates using
summary statistics. The proposed recognition algorithm exploits temporal
and spatial characteristics of gestures via dynamic programming
and Markovian process. The algorithm predicts corresponding index
of incremental input data in the templates in an on-line mode.
Accumulated consistency in the sequence of prediction provides a
similarity measurement (Score) between input data and the templates.
The algorithm provides an intuitive mechanism for automatic detection
of start/end frames of continuous gestures. In the present paper,
we consider isolated gestures. The performance of RM is evaluated
using four datasets - artificial (W TTest), hand motion (Yang) and
FDO (tracker, vision-based ). RM achieves comparable results which
are in agreement with other on-line and off-line algorithms such as
hidden Markov model (HMM) and dynamic time warping (DTW).
The proposed algorithm has the additional advantage of providing
timely feedback for training purposes.
Abstract: In this paper as showed a non-invasive 3D eye tracker
for optometry clinical applications. Measurements of biomechanical
variables in clinical practice have many font of errors associated with
traditional procedments such cover test (CT), near point of
accommodation (NPC), eye ductions (ED), eye vergences (EG) and,
eye versions (ES). Ocular motility should always be tested but all
evaluations have a subjective interpretations by practitioners, the
results is based in clinical experiences, repeatability and accuracy
don-t exist. Optometric-lab is a tool with 3 (tree) analogical video
cameras triggered and synchronized in one acquisition board AD.
The variables globe rotation angle and velocity can be quantified.
Data record frequency was performed with 27Hz, camera calibration
was performed in a know volume and image radial distortion
adjustments.
Abstract: Visual attention allows user to select the most relevant
information to ongoing behaviour. This paper presents a study on; i)
the performance of people measurements, ii) accurateness of people
measurement of the peaks that correspond to chemical quantities
from the Magnetic Resonance Spectroscopy (MRS) graphs and iii)
affects of people measurements to the algorithm-based diagnosis.
Participant-s eye-movement was recorded using eye-tracker tool
(Eyelink II). This experiment involves three participants for
examining 20 MRS graphs to estimate the peaks of chemical
quantities which indicate the abnormalities associated with
Cerebellar Tumours (CT). The status of each MRS is verified by
using decision algorithm. Analysis involves determination of
humans-s eye movement pattern in measuring the peak of
spectrograms, scan path and determining the relationship of
distributions of fixation durations with the accuracy of measurement.
In particular, the eye-tracking data revealed which aspects of the
spectrogram received more visual attention and in what order they
were viewed. This preliminary investigation provides a proof of
concept for use of the eye tracking technology as the basis for
expanded CT diagnosis.
Abstract: This paper describes the design of a voltage based maximum power point tracker (MPPT) for photovoltaic (PV) applications. Of the various MPPT methods, the voltage based method is considered to be the simplest and cost effective. The major disadvantage of this method is that the PV array is disconnected from the load for the sampling of its open circuit voltage, which inevitably results in power loss. Another disadvantage, in case of rapid irradiance variation, is that if the duration between two successive samplings, called the sampling period, is too long there is a considerable loss. This is because the output voltage of the PV array follows the unchanged reference during one sampling period. Once a maximum power point (MPP) is tracked and a change in irradiation occurs between two successive samplings, then the new MPP is not tracked until the next sampling of the PV array voltage. This paper proposes an MPPT circuit in which the sampling interval of the PV array voltage, and the sampling period have been shortened. The sample and hold circuit has also been simplified. The proposed circuit does not utilize a microcontroller or a digital signal processor and is thus suitable for low cost and low power applications.
Abstract: In this work a new platform for mobile-health systems is
presented. System target application is providing decision support to
rescue corps or military medical personnel in combat areas. Software
architecture relies on a distributed client-server system that manages a
wireless ad-hoc networks hierarchy in which several different types of
client operate. Each client is characterized for different hardware and
software requirements. Lower hierarchy levels rely in a network of
completely custom devices that store clinical information and patient
status and are designed to form an ad-hoc network operating in the
2.4 GHz ISM band and complying with the IEEE 802.15.4 standard
(ZigBee). Medical personnel may interact with such devices, that are
called MICs (Medical Information Carriers), by means of a PDA
(Personal Digital Assistant) or a MDA (Medical Digital Assistant),
and transmit the information stored in their local databases as well as
issue a service request to the upper hierarchy levels by using IEEE
802.11 a/b/g standard (WiFi). The server acts as a repository that
stores both medical evacuation forms and associated events (e.g., a
teleconsulting request). All the actors participating in the diagnostic
or evacuation process may access asynchronously to such repository
and update its content or generate new events. The designed system
pretends to optimise and improve information spreading and flow
among all the system components with the aim of improving both
diagnostic quality and evacuation process.
Abstract: In this paper, a new approach for quality assessment
tasks in lossy compressed digital video is proposed. The research
activity is based on the visual fixation data recorded by an eye
tracker. The method involved both a new paradigm for subjective
quality evaluation and the subsequent statistical analysis to match
subjective scores provided by the observer to the data obtained from
the eye tracker experiments. The study brings improvements to the
state of the art, as it solves some problems highlighted in literature.
The experiments prove that data obtained from an eye tracker can be
used to classify videos according to the level of impairment due to
compression. The paper presents the methodology, the experimental
results and their interpretation. Conclusions suggest that the eye
tracker can be useful in quality assessment, if data are collected and
analyzed in a proper way.
Abstract: This paper is concerned with motion recognition based fuzzy WP(Wavelet Packet) feature extraction approach from Vicon physical data sets. For this purpose, we use an efficient fuzzy mutual-information-based WP transform for feature extraction. This method estimates the required mutual information using a novel approach based on fuzzy membership function. The physical action data set includes 10 normal and 10 aggressive physical actions that measure the human activity. The data have been collected from 10 subjects using the Vicon 3D tracker. The experiments consist of running, seating, and walking as physical activity motion among various activities. The experimental results revealed that the presented feature extraction approach showed good recognition performance.
Abstract: Solar energy has a major role in renewable energy
resources. Solar Cell as a basement of solar system has attracted lots
of research. To conduct a study about solar energy system, an
authenticated model is required. Diode base PV models are widely
used by researchers. These models are classified based on the number
of diodes used in them. Single and two-diode models are well
studied. Single-diode models may have two, three or four elements.
In this study, these solar cell models are examined and the simulation
results are compared to each other. All PV models are re-designed in
the Matlab/Simulink software and they examined by certain test
conditions and parameters. This paper provides comparative studies
of these models and it tries to compare the simulation results with
manufacturer-s data sheet to investigate model validity and accuracy.
The results show a four- element single-diode model is accurate and
has moderate complexity in contrast to the two-diode model with
higher complexity and accuracy
Abstract: The paper presents an on-line recognition machine
(RM) for continuous/isolated, dynamic and static gestures that arise
in Flight Deck Officer (FDO) training. RM is based on generic pattern
recognition framework. Gestures are represented as templates using
summary statistics. The proposed recognition algorithm exploits temporal
and spatial characteristics of gestures via dynamic programming
and Markovian process. The algorithm predicts corresponding index
of incremental input data in the templates in an on-line mode.
Accumulated consistency in the sequence of prediction provides a
similarity measurement (Score) between input data and the templates.
The algorithm provides an intuitive mechanism for automatic detection
of start/end frames of continuous gestures. In the present paper,
we consider isolated gestures. The performance of RM is evaluated
using four datasets - artificial (W TTest), hand motion (Yang) and
FDO (tracker, vision-based ). RM achieves comparable results which
are in agreement with other on-line and off-line algorithms such as
hidden Markov model (HMM) and dynamic time warping (DTW).
The proposed algorithm has the additional advantage of providing
timely feedback for training purposes.
Abstract: Tool Tracker is a client-server based application. It is essentially a catalogue of various network monitoring and management tools that are available online. There is a database maintained on the server side that contains the information about various tools. Several clients can access this information simultaneously and utilize this information. The various categories of tools considered are packet sniffers, port mappers, port scanners, encryption tools, and vulnerability scanners etc for the development of this application. This application provides a front end through which the user can invoke any tool from a central repository for the purpose of packet sniffing, port scanning, network analysis etc. Apart from the tool, its description and the help files associated with it would also be stored in the central repository. This facility will enable the user to view the documentation pertaining to the tool without having to download and install the tool. The application would update the central repository with the latest versions of the tools. The application would inform the user about the availability of a newer version of the tool currently being used and give the choice of installing the newer version to the user. Thus ToolTracker provides any network administrator that much needed abstraction and ease-ofuse with respect to the tools that he can use to efficiently monitor a network.
Abstract: Brand name plays a vital role for in-shop buying
behavior of consumers and mutated brand name may affect the
selling of leading branded products. In Indian market, there are many
products with mutated brand names which are either orthographically
or phonologically similar. Due to presence of such products, Indian
consumers very often fall under confusion when buying some
regularly used stuff. Authors of the present paper have attempted to
demonstrate relationship between less attention and false recognition
of mutated brand names during a product selection process. To
achieve this goal, visual attention study was conducted on 15 male
college students using eye-tracker against a mutated brand name and
errors in recognition were noted using questionnaire. Statistical
analysis of the acquired data revealed that there was more false
recognition of mutated brand name when less attention was paid
during selection of favorite product. Moreover, it was perceived that
eye tracking is an effective tool for analyzing false recognition of
brand name mutation.