Abstract: Cross-laminated timber is increasingly being used in
the construction of high-rise buildings due to its simple
manufacturing system. In term of fire resistance, cross-laminated
timber panels are promoted as having excellent fire resistance,
comparable to that of non-combustible materials and to heavy
timber construction, due to the ability of thick wood assemblies to
char slowly at a predictable rate while maintaining most of their
strength during the fire exposure. This paper presents an overview of
fire performance of cross-laminated timber and evaluation of its
resistance to elevated temperature in comparison to homogeneous
timber panels. Charring rates for cross-laminated timber panels of
those obtained experimentally were compared with those provided by
Eurocode simplified calculation methods.