Abstract: The performances of a thermoacoustic travelling-wave
refrigerator are presented. Developed in the frame of the European
project called THATEA, it is designed for providing 600 W at a
temperature of 233 K with an efficiency of 40 % relative to the
Carnot efficiency. This paper presents the device and the results of
the first measurements. For a cooling power of 210 W, a coefficient
of performance relative to Carnot of 30 % is achieved when the
refrigerator is coupled with an existing standing-wave engine.
Abstract: Prickly pear juice has received renewed attention with regard to the effects of processing and preservation on its sensory qualities (colour, taste, flavour, aroma, astringency, visual browning and overall acceptability). Juice was prepared by homogenizing fruit and treating the pulp with pectinase (Aspergillus niger). Juice treatments applied were sugar addition, acidification, heat-treatment, refrigeration, and freezing and thawing. Prickly pear pulp and juice had unique properties (low pH 3.88, soluble solids 3.68 oBrix and high titratable acidity 0.47). Sensory profiling and descriptive analyses revealed that non-treated juice had a bitter taste with high astringency whereas treated prickly pear was significantly sweeter. All treated juices had a good sensory acceptance with values approximating or exceeding 7. Regression analysis of the consumer sensory attributes for non-treated prickly pear juice indicated an overwhelming rejection, while treated prickly pear juice received overall acceptability. Thus, educed favourable sensory responses and may have positive implications for consumer acceptability.
Abstract: This paper provides an exergy analysis of the multistage refrigeration cycle used for C2+ recovery plant. The behavior of an industrial refrigeration cycle with refrigerant propane has been investigated by the exergy method. A computational model based on the exergy analysis is presented for the investigation of the effects of the valves on the exergy losses, the second law of efficiency, and the coefficient of performance (COP) of a vapor compression refrigeration cycle. The equations of exergy destruction and exergetic efficiency for the main cycle components such as evaporators, condensers, compressors, and expansion valves are developed. The relations for the total exergy destruction in the cycle and the cycle exergetic efficiency are obtained. An ethane recovery unit with its refrigeration cycle has been simulated to prepare the exergy analysis. Using a typical actual work input value; the exergetic efficiency of the refrigeration cycle is determined to be 39.90% indicating a great potential for improvements. The simulation results reveal that the exergetic efficiencies of the heat exchanger and expansion sections get the lowest rank among the other compartments of refrigeration cycle. Refrigeration calculations have been carried out through the analysis of T–S and P–H diagrams where coefficient of performance (COP) was obtained as 1.85. The novelty of this article includes the effect and sensitivity analysis of molar flow, pressure drops and temperature on the exergy efficiency and coefficient of performance of the cycle.
Abstract: Accurate and comprehensive thermodynamic properties of pure and mixture of refrigerants are in demand by both producers and users of these materials. Information about thermodynamic properties is important initially to qualify potential candidates for working fluids in refrigeration machinery. From practical point of view, Refrigerants and refrigerant mixtures are widely used as working fluids in many industrial applications, such as refrigerators, heat pumps, and power plants The present work is devoted to evaluating seven cubic equations of state (EOS) in predicting gas and liquid phase volumetric properties of nine ozone-safe refrigerants both in super and sub-critical regions. The evaluations, in sub-critical region, show that TWU and PR EOS are capable of predicting PVT properties of refrigerants R32 within 2%, R22, R134a, R152a and R143a within 1% and R123, R124, R125, TWU and PR EOS's, from literature data are 0.5% for R22, R32, R152a, R143a, and R125, 1% for R123, R134a, and R141b, and 2% for R124. Moreover, SRK EOS predicts PVT properties of R22, R125, and R123 to within aforementioned errors. The remaining EOS's predicts volumetric properties of this class of fluids with higher errors than those above mentioned which are at most 8%.In general, the results are in favor of the preference of TWU and PR EOS over other remaining EOS's in predicting densities of all mentioned refrigerants in both super and sub critical regions. Typically, this refrigerant is known to offer advantages such as ozone depleting potential equal to zero, Global warming potential equal to 140, and no toxic.
Abstract: A solar refrigeration system based on the adsorptiondesorption
phenomena is designed and analyzed. An annular tubular
generator filled with silica gel adsorbent and with a perforated inner
cylinder is integrated within a flat solar collector. The working fluid
in the refrigeration cycle is water. The thermodynamic analysis and
because of the temperature level that could be attained with a flat
solar collector it is required that the system operates under vacuum
conditions. In order to enhance the performance of the system and to
get uniform temperature in the silica gel and higher desorbed mass,
an apparatus for rotation of the generator is incorporated in the
system. Testing is carried out and measurements are taken on the
designed installation. The effect of rotation is checked on the
temperature distribution and on the performance of this machine and
compared to the flat solar collector with fixed generator.
Abstract: PCMs have always been viewed as a suitable
candidate for off peak thermal storage, particularly for refrigeration
systems, due to the high latent energy densities of these materials.
However, due to the need to have them encapsulated within a
container this density is reduced. Furthermore, PCMs have a low
thermal conductivity which reduces the useful amount of energy
which can be stored. To consider these factors, the true energy
storage density of a PCM system was proposed and optimised for
PCMs encapsulated in slabs. Using a validated numerical model of
the system, a parametric study was undertaken to investigate the
impact of the slab thickness, gap between slabs and the mass flow
rate. The study showed that, when optimised, a PCM system can
deliver a true energy storage density between 53% and 83% of the
latent energy density of the PCM.
Abstract: This paper describes a methodology for remote
performance monitoring of retail refrigeration systems. The proposed
framework starts with monitoring of the whole refrigeration circuit
which allows detecting deviations from expected behavior caused by
various faults and degradations. The subsequent diagnostics methods
drill down deeper in the equipment hierarchy to more specifically
determine root causes. An important feature of the proposed concept
is that it does not require any additional sensors, and thus, the
performance monitoring solution can be deployed at a low
installation cost. Moreover only a minimum of contextual
information is required, which also substantially reduces time and
cost of the deployment process.
Abstract: The present work deals with thermodynamic analysis
of cascade refrigeration system using ozone friendly refrigerants pair
R507A and R23. R507A is azeotropic mixture composed of HFC
refrigerants R125/R143a (50%/50% wt.). R23 is a single component
HFC refrigerant used as replacement to CFC refrigerant R13 in low
temperature applications. These refrigerants have zero ozone
depletion potential and are non-flammable and as R507A an
azeotropic mixture there is no problem of temperature glide. This
study thermodynamically analyzed R507A-R23 cascade refrigeration
system to optimize the design and operating parameters of the
system. The design and operating parameters include: Condensing,
evaporating, subcooling and superheating temperatures in the high
temperature circuit, temperature difference in the cascade heat
exchanger, Condensing, evaporating, subcooling and superheating
temperatures in the low temperature circuit.
Abstract: Capacity and efficiency of any refrigerating system
diminish rapidly as the difference between the evaporating and
condensing temperature is increased by reduction in the evaporator
temperature. The single stage vapour compression refrigeration
system is limited to an evaporator temperature of -40 0C. Below
temperature of -40 0C the either cascade refrigeration system or multi
stage vapour compression system is employed. Present work
describes thermal design of main three heat exchangers namely
condenser (HTS), cascade condenser and evaporator (LTS) of
R404A-R508B and R410A-R23 cascade refrigeration system. Heat
transfer area of condenser (HTS), cascade condenser and evaporator
(LTS) for both systems have been compared and the effect of
condensing and evaporating temperature on heat-transfer area for
both systems have been studied under same operating condition. The
results shows that the required heat-transfer area of condenser and
cascade condenser for R410A-R23 cascade system is lower than the
R404A-R508B cascade system but heat transfer area of evaporator is
similar for both the system. The heat transfer area of condenser and
cascade condenser decreases with increase in condensing temperature
(Tc), whereas the heat transfer area of cascade condenser and
evaporator increases with increase in evaporating temperature (Te).
Abstract: In this study thermodynamic performance analysis of a
combined organic Rankine cycle and ejector refrigeration cycle is
carried out for use of low-grade heat source in the form of sensible
energy. Special attention is paid to the effects of system parameters
including the turbine inlet temperature and turbine inlet pressure on the
characteristics of the system such as ratios of mass flow rate, net work
production, and refrigeration capacity as well as the coefficient of
performance and exergy efficiency of the system. Results show that
for a given source the coefficient of performance increases with
increasing of the turbine inlet pressure. However, the exergy
efficiency has an optimal condition with respect to the turbine inlet
pressure.
Abstract: Heat powered solid sorption is a feasible alternative to
electrical vapor compression refrigeration systems. In this paper,
activated carbon (powder type Maxsorb and fiber type ACF-A10)-
CO2 based adsorption cooling cycles are studied using the pressuretemperature-
concentration (P-T-W) diagram. The specific cooling
effect (SCE) and the coefficient of performance (COP) of these two
cooling systems are simulated for the driving heat source
temperatures ranging from 30 ºC to 90 ºC in terms of different
cooling load temperatures with a cooling source temperature of 25
ºC. It is found from the present analysis that Maxsorb-CO2 couple
shows higher cooling capacity and COP. The maximum COPs of
Maxsorb-CO2 and ACF(A10)-CO2 based cooling systems are found
to be 0.15 and 0.083, respectively. The main innovative feature of
this cooling cycle is the ability to utilize low temperature waste heat
or solar energy using CO2 as the refrigerant, which is one of the best
alternative for applications where flammability and toxicity are not
allowed.
Abstract: Capacity and efficiency of any refrigerating system
diminish rapidly as the difference between the evaporating and
condensing temperature is increased by a reduction in the evaporator
temperature. The single stage vapour compression refrigeration
system using various refrigerants are limited to an evaporator
temperature of -40 0C. Below temperature of -40 0C the either
cascade refrigeration system or multi stage vapour compression
system is employed. Present work describes thermal design of
condenser (HTS), cascade condenser and evaporator (LTS) of
R404A-R508B and R410A-R23 cascade refrigeration system. Heat
transfer area of condenser, cascade condenser and evaporator for
both systems are compared and the effect of condenser and
evaporator temperature on heat-transfer area for both systems is
studied under same operating condition. The results shows that the
required heat-transfer area of condenser and cascade condenser for
R410A-R23 cascade system is lower than the R404A-R508B cascade
system but heat transfer area of evaporator is similar for both the
system. The heat transfer area of condenser and cascade condenser
decreases with increase in condenser temperature (Tc), whereas the
heat transfer area of cascade condenser and evaporator increases with
increase in evaporator temperature (Te).