Abstract: power-line networks are promise infrastructure for
broadband services provision to end users. However, the network
performance is affected by stochastic channel changing which is due
to load impedances, number of branches and branched line lengths. It
has been proposed that multi-carrier modulations techniques such as
orthogonal frequency division multiplexing (OFDM), Multi-Carrier
Spread Spectrum (MC-SS), wavelet OFDM can be used in such
environment. This paper investigates the performance of different
indoor topologies of power-line networks that uses MC-SS
modulation scheme.It is observed that when a branch is added in the
link between sending and receiving end of an indoor channel an
average of 2.5dB power loss is found. In additional, when the branch
is added at a node an average of 1dB power loss is found.
Additionally when the terminal impedances of the branch change
from line characteristic impedance to impedance either higher or
lower values the channel performances were tremendously improved.
For example changing terminal load from characteristic impedance
(85 .) to 5 . the signal to noise ratio (SNR) required to attain the
same performances were decreased from 37dB to 24dB respectively.
Also, changing the terminal load from channel characteristic
impedance (85 .) to very higher impedance (1600 .) the SNR
required to maintain the same performances were decreased from
37dB to 23dB. The result concludes that MC-SS performs better
compared with OFDM techniques in all aspects and especially when
the channel is terminated in either higher or lower impedances.
Abstract: This paper presents two different sequential switching hybrid-modulation strategies and implemented for cascaded multilevel inverters. Hybrid modulation strategies represent the combinations of Fundamental-frequency pulse width modulation (FFPWM) and Multilevel sinusoidal-modulation (MSPWM) strategies, and are designed for performance of the well-known Alternative Phase opposition disposition (APOD), Phase shifted carrier (PSC). The main characteristics of these modulations are the reduction of switching losses with good harmonic performance, balanced power loss dissipation among the devices with in a cell, and among the series-connected cells. The feasibility of these modulations is verified through spectral analysis, power loss analysis and simulation.
Abstract: This paper presents a new and efficient approach for capacitor placement in radial distribution systems that determine the optimal locations and size of capacitor with an objective of improving the voltage profile and reduction of power loss. The solution methodology has two parts: in part one the loss sensitivity factors are used to select the candidate locations for the capacitor placement and in part two a new algorithm that employs Plant growth Simulation Algorithm (PGSA) is used to estimate the optimal size of capacitors at the optimal buses determined in part one. The main advantage of the proposed method is that it does not require any external control parameters. The other advantage is that it handles the objective function and the constraints separately, avoiding the trouble to determine the barrier factors. The proposed method is applied to 9, 34, and 85-bus radial distribution systems. The solutions obtained by the proposed method are compared with other methods. The proposed method has outperformed the other methods in terms of the quality of solution.
Abstract: This paper presents a new method which applies an
artificial bee colony algorithm (ABC) for capacitor placement in
distribution systems with an objective of improving the voltage profile
and reduction of power loss. The ABC algorithm is a new population
based meta heuristic approach inspired by intelligent foraging behavior
of honeybee swarm. The advantage of ABC algorithm is that
it does not require external parameters such as cross over rate and
mutation rate as in case of genetic algorithm and differential evolution
and it is hard to determine these parameters in prior. The other
advantage is that the global search ability in the algorithm is implemented
by introducing neighborhood source production mechanism
which is a similar to mutation process. To demonstrate the validity
of the proposed algorithm, computer simulations are carried out on
69-bus system and compared the results with the other approach
available in the literature. The proposed method has outperformed the
other methods in terms of the quality of solution and computational
efficiency.
Abstract: A mathematical model for determining the overall efficiency
of a multistage tractor gearbox including all gear, lubricant,
surface finish related parameters and operating conditions is
presented. Sliding friction, rolling friction and windage losses were
considered as the main sources of power loss in the gearing system. A
computer code in FORTRAN was developed to simulate the model.
Sliding friction contributes about 98% of the total power loss for
gear trains operating at relatively low speeds (less than 2000 rpm
input speed). Rolling frictional losses decrease with increased load
while windage losses are only significant for gears running at very
high speeds (greater than 3000 rpm). The results also showed that the
overall efficiency varies over the path of contact of the gear meshes
ranging between 94% to 99.5%.
Abstract: In this paper, half bridge DC-DC converters with
transformer isolation presented in the literature are analyzed for highcurrent
and low-voltage applications under the same operation
conditions, and compared in terms of losses and efficiency. The
conventional and improved half-bridge DC-DC converters are
simulated, and current and voltage waveforms are obtained for input
voltage Vdc=500V, output current IO=450A, output voltage VO=38V
and switching frequency fS=20kHz. IGBTs are used as power
semiconductor switches. The power losses of the semiconductor
devices are calculated from current and voltage waveforms. From
simulation results, it is seen that the capacitor switched half bridge
converter has the best efficiency value, and can be preferred at high
power and high frequency applications.
Abstract: Optical 1x12 fused-taper-twisted polymer optical fiber (POF) couplers has been fabricated by a perform technique. Characterization of the coupler which proposed to be used in passive night vision application to tracking a blind sport area was reported. During the development process of fused-taper-twisted POF couplers was carried out, red LED fully utilized to be injected into the couplers to test the quality of fabricated couplers. Some characterization parameters, such as optical output power, POFs attenuation characteristics and power losses on the network were observed. The maximum output power efficiency of the coupler is about 40%, but it can be improved gradually through experience and practice.
Abstract: The tracing methods determine the contribution the
power system sources have in their supplying. These methods can be
used to assess the transmission prices, but also to recover the
transmission fixed cost. In this paper is presented the influence of the
modification of commons structure has on the specific price of transfer
and on active power losses. The authors propose a power losses
allocation method, based on Kirschen-s method. The system operator
must make use of a few basic principles about allocation. The only
necessary information is the power flows on system branches and the
modifications applied to power system buses. In order to illustrate this
method, the 25-bus test system is used, elaborated within the Electrical
Power Engineering Department, from Timisoara, Romania.
Abstract: This paper proposes a new methodology for the
optimal allocation and sizing of Embedded Generation (EG)
employing Real Coded Genetic Algorithm (RCGA) to minimize the
total power losses and to improve voltage profiles in the radial
distribution networks. RCGA is a method that uses continuous
floating numbers as representation which is different from
conventional binary numbers. The RCGA is used as solution tool,
which can determine the optimal location and size of EG in radial
system simultaneously. This method is developed in MATLAB. The
effect of EG units- installation and their sizing to the distribution
networks are demonstrated using 24 bus system.
Abstract: This paper describes the design of a voltage based maximum power point tracker (MPPT) for photovoltaic (PV) applications. Of the various MPPT methods, the voltage based method is considered to be the simplest and cost effective. The major disadvantage of this method is that the PV array is disconnected from the load for the sampling of its open circuit voltage, which inevitably results in power loss. Another disadvantage, in case of rapid irradiance variation, is that if the duration between two successive samplings, called the sampling period, is too long there is a considerable loss. This is because the output voltage of the PV array follows the unchanged reference during one sampling period. Once a maximum power point (MPP) is tracked and a change in irradiation occurs between two successive samplings, then the new MPP is not tracked until the next sampling of the PV array voltage. This paper proposes an MPPT circuit in which the sampling interval of the PV array voltage, and the sampling period have been shortened. The sample and hold circuit has also been simplified. The proposed circuit does not utilize a microcontroller or a digital signal processor and is thus suitable for low cost and low power applications.
Abstract: Importance of environmental efficiency of electric power industry stems from high demand for energy combined with global warming concerns. It is especially essential for the world largest economies like that of the United States. The paper introduces a Data Envelopment Analysis (DEA) model of environmental efficiency using indicators of fossil fuels utilization, emissions rate, and electric power losses. Using DEA is advantageous in this situation over other approaches due to its nonparametric nature. The paper analyzes data for the period of 1990 - 2006 by comparing actual yearly levels in each dimension with the best values of partial indicators for the period. As positive factors of efficiency, tendency to the decline in emissions rates starting 2000, and in electric power losses starting 2004 may be mentioned together with increasing trend of fuel utilization starting 1999. As a result, dynamics of environmental efficiency is positive starting 2002. The main concern is the decline in fossil fuels utilization in 2006. This negative change should be reversed to comply with ecological and economic requirements.
Abstract: The iron loss is a source of detuning in vector controlled
induction motor drives if the classical rotor vector controller is used for
decoupling. In fact, the field orientation will not be satisfied and the
output torque will not truck the reference torque mostly used by Loss
Model Controllers (LMCs). In addition, this component of loss, among
others, may be excessive if the vector controlled induction motor is
driving light loads. In this paper, the series iron loss model is used to
develop a vector controller immune to iron loss effect and then an LMC
to minimize the total power loss using the torque generated by the speed
controller.
Abstract: To minimize power losses, it is important to
determine the location and size of local generators to be placed in
unbalanced power distribution systems. On account of some inherent
features of unbalanced distribution systems, such as radial structure,
large number of nodes, a wide range of X/R ratios, the conventional
techniques developed for the transmission systems generally fail on
the determination of optimum size and location of distributed
generators (DGs). This paper presents a simple method for
investigating the problem of contemporaneously choosing best
location and size of DG in three-phase unbalanced radial distribution
system (URDS) for power loss minimization and to improve the
voltage profile of the system. Best location of the DG is determined
by using voltage index analysis and size of DG is computed by
variational technique algorithm according to available standard size
of DGs. This paper presents the results of simulations for 25-bus and
IEEE 37- bus Unbalanced Radial Distribution system.
Abstract: Recently, distributed generation technologies have received much attention for the potential energy savings and reliability assurances that might be achieved as a result of their widespread adoption. Fueling the attention have been the possibilities of international agreements to reduce greenhouse gas emissions, electricity sector restructuring, high power reliability requirements for certain activities, and concern about easing transmission and distribution capacity bottlenecks and congestion. So it is necessary that impact of these kinds of generators on distribution feeder reconfiguration would be investigated. This paper presents an approach for distribution reconfiguration considering Distributed Generators (DGs). The objective function is summation of electrical power losses A Tabu search optimization is used to solve the optimal operation problem. The approach is tested on a real distribution feeder.
Abstract: This paper proposes a Particle Swarm Optimization
(PSO) based technique for the optimal allocation of Distributed
Generation (DG) units in the power systems. In this paper our aim is
to decide optimal number, type, size and location of DG units for
voltage profile improvement and power loss reduction in distribution
network. Two types of DGs are considered and the distribution load
flow is used to calculate exact loss. Load flow algorithm is combined
appropriately with PSO till access to acceptable results of this
operation. The suggested method is programmed under MATLAB
software. Test results indicate that PSO method can obtain better
results than the simple heuristic search method on the 30-bus and 33-
bus radial distribution systems. It can obtain maximum loss reduction
for each of two types of optimally placed multi-DGs. Moreover,
voltage profile improvement is achieved.
Abstract: This paper presents a novel approach for optimal
reconfiguration of radial distribution systems. Optimal
reconfiguration involves the selection of the best set of branches to
be opened, one each from each loop, such that the resulting radial
distribution system gets the desired performance. In this paper an
algorithm is proposed based on simple heuristic rules and identified
an effective switch status configuration of distribution system for the
minimum loss reduction. This proposed algorithm consists of two
parts; one is to determine the best switching combinations in all loops
with minimum computational effort and the other is simple optimum
power loss calculation of the best switching combination found in
part one by load flows. To demonstrate the validity of the proposed
algorithm, computer simulations are carried out on 33-bus system.
The results show that the performance of the proposed method is
better than that of the other methods.
Abstract: Voltage collapse is instability of heavily loaded electric
power systems that cause to declining voltages and blackout. Power
systems are predicated to become more heavily loaded in the future
decade as the demand for electric power rises while economic and
environmental concerns limit the construction of new transmission
and generation capacity. Heavily loaded power systems are closer to
their stability limits and voltage collapse blackouts will occur if
suitable monitoring and control measures are not taken. To control
transmission lines, it can be used from FACTS devices.
In this paper Harmony search algorithm (HSA) and Genetic
Algorithm (GA) have applied to determine optimal location of
FACTS devices in a power system to improve power system stability.
Three types of FACTS devices (TCPAT, UPFS, and SVC) have been
introduced. Bus under voltage has been solved by controlling reactive
power of shunt compensator. Also a combined series-shunt
compensators has been also used to control transmission power flow
and bus voltage simultaneously.
Different scenarios have been considered. First TCPAT, UPFS, and
SVC are placed solely in transmission lines and indices have been
calculated. Then two types of above controller try to improve
parameters randomly. The last scenario tries to make better voltage
stability index and losses by implementation of three types controller
simultaneously. These scenarios are executed on typical 34-bus test
system and yields efficiency in improvement of voltage profile and
reduction of power losses; it also may permit an increase in power
transfer capacity, maximum loading, and voltage stability margin.
Abstract: Design and evaluation of reciprocating compressors
should include a pulsation study. The object is to ensure that
predicted pulsation levels meet guidelines to limit vibration, shaking
forces, noise, associated pressure drops, horsepower losses and
fabrication cost and time to acceptable levels. This paper explains
procedures and recommendations to select and size pulsation
suppression devices to obtain optimum arrangement in terms of
pulsation, vibration, shaking forces, performance, reliability, safety,
operation, maintenance and commercial conditions. Model and
advanced formulations for pulsation study are presented. The effect
of the full fluid dynamic model on the prediction of pulsation waves
and resulting frequency spectrum distributions are discussed.
Advanced and optimum methods of controlling pulsations are
highlighted. Useful recommendations and guidelines for pulsation
control, piping pulsation analysis, pulsation vessel design, shaking
forces, low pressure drop orifices, pulsation study report and devices
to mitigate pulsation and shaking problems are discussed.
Abstract: This paper presents an optimization technique to economic load dispatch (ELD) problems with considering the daily load patterns and generator constraints using a particle swarm optimization (PSO). The objective is to minimize the fuel cost. The optimization problem is subject to system constraints consisting of power balance and generation output of each units. The application of a constriction factor into PSO is a useful strategy to ensure convergence of the particle swarm algorithm. The proposed method is able to determine, the output power generation for all of the power generation units, so that the total constraint cost function is minimized. The performance of the developed methodology is demonstrated by case studies in test system of fifteen-generation units. The results show that the proposed algorithm scan give the minimum total cost of generation while satisfying all the constraints and benefiting greatly from saving in power loss reduction
Abstract: This work presents a new algorithm based on a combination of fuzzy (FUZ), Dynamic Programming (DP), and Genetic Algorithm (GA) approach for capacitor allocation in distribution feeders. The problem formulation considers two distinct objectives related to total cost of power loss and total cost of capacitors including the purchase and installation costs. The novel formulation is a multi-objective and non-differentiable optimization problem. The proposed method of this article uses fuzzy reasoning for sitting of capacitors in radial distribution feeders, DP for sizing and finally GA for finding the optimum shape of membership functions which are used in fuzzy reasoning stage. The proposed method has been implemented in a software package and its effectiveness has been verified through a 9-bus radial distribution feeder for the sake of conclusions supports. A comparison has been done among the proposed method of this paper and similar methods in other research works that shows the effectiveness of the proposed method of this paper for solving optimum capacitor planning problem.