Abstract: A conventional optical coherence tomography (OCT) system has limited imaging depth, which is 1-2 mm, and suffers unwanted noise such as speckle noise. The motorized-stage-based OCT system, using a common-path Fourier-domain optical coherence tomography (CP-FD-OCT) configuration, provides enhanced imaging depth and less noise so that we can overcome these limitations. Using this OCT systems, OCT images were obtained from an onion, and their subsurface structure was observed. As a result, the images obtained using the developed motorized-stage-based system showed enhanced imaging depth than the conventional system, since it is real-time accurate depth tracking. Consequently, the developed CP-FD-OCT systems and algorithms have good potential for the further development of endoscopic OCT for microsurgery.
Abstract: Background: To compare the thinning patterns of the
ganglion cell-inner plexiform layer (GCIPL) and peripapillary retinal
nerve fiber layer (pRNFL) as measured using Cirrus high-definition
optical coherence tomography (HD-OCT) in patients with visual field
(VF) defects that respect the vertical meridian. Methods: Twenty eyes of eleven patients with VF defects that
respect the vertical meridian were enrolled retrospectively. The
thicknesses of the macular GCIPL and pRNFL were measured using
Cirrus HD-OCT. The 5% and 1% thinning area index (TAI) was
calculated as the proportion of abnormally thin sectors at the 5% and
1% probability level within the area corresponding to the affected VF.
The 5% and 1% TAI were compared between the GCIPL and pRNFL
measurements. Results: The color-coded GCIPL deviation map showed a
characteristic vertical thinning pattern of the GCIPL, which is also
seen in the VF of patients with brain lesions. The 5% and 1% TAI
were significantly higher in the GCIPL measurements than in the
pRNFL measurements (all P < 0.01). Conclusions: Macular GCIPL analysis clearly visualized a
characteristic topographic pattern of retinal ganglion cell (RGC) loss
in patients with VF defects that respect the vertical meridian, unlike
pRNFL measurements. Macular GCIPL measurements provide more
valuable information than pRNFL measurements for detecting the
loss of RGCs in patients with retrograde degeneration of the optic
nerve fibers.
Abstract: Optical Coherence Tomography (OCT) combined
with the Confocal Microscopy, as a noninvasive method, permits the
determinations of materials defects in the ceramic layers depth. For
this study 256 anterior and posterior metal and integral ceramic fixed
partial dentures were used, made with Empress (Ivoclar), Wollceram
and CAD/CAM (Wieland) technology. For each investigate area 350
slices were obtain and a 3D reconstruction was perform from each
stuck. The Optical Coherent Tomography, as a noninvasive method,
can be used as a control technique in integral ceramic technology,
before placing those fixed partial dentures in the oral cavity. The
purpose of this study is to evaluate the capability of En face Optical
Coherence Tomography (OCT) combined with a fluorescent method
in detection and analysis of possible material defects in metalceramic
and integral ceramic fixed partial dentures. As a conclusion,
it is important to have a non invasive method to investigate fixed
partial prostheses before their insertion in the oral cavity in order to
satisfy the high stress requirements and the esthetic function.
Abstract: The intention of this lessons is to assess the probability
of optical coherence tomography (OCT) for biometric recognition.
The OCT is the foundation on an optical signal acquisition and
processing method and has the micrometer-resolution. In this study,
we used the porcine skin for verifying the abovementioned means. The
porcine tissue was sound acknowledged for structural and
immunohistochemical similarity with human skin, so it could be
suitable for pre-clinical trial as investigational specimen. For this
reason, it was tattooed by the tattoo machine with the tattoo-pigment.
We detected the pattern of the tattooed skin by the OCT according to
needle speed. The result was consistent with the histology images.
This result showed that the OCT was effective to examine the tattooed
skin section noninvasively. It might be available to identify
morphological changes inside the skin.
Abstract: The fixed partial dentures are mainly used in the frontal
part of the dental arch because of their great esthetics. There are
several factors that are associated with the stress state created in
ceramic restorations, including: thickness of ceramic layers,
mechanical properties of the materials, elastic modulus of the
supporting substrate material, direction, magnitude and frequency of
applied load, size and location of occlusal contact areas, residual
stresses induced by processing or pores, restoration-cement
interfacial defects and environmental defects. The purpose of this
study is to evaluate the capability of Polarization Sensitive Optical
Coherence Tomography (PSOCT) in detection and analysis of
possible material defects in metal-ceramic and integral ceramic fixed
partial dentures. As a conclusion, it is important to have a non
invasive method to investigate fixed partial prostheses before their
insertion in the oral cavity in order to satisfy the high stress
requirements and the esthetic function.
Abstract: The purpose of this study is to present a non invasive
method for the marginal adaptation evaluation in class V composite
restorations. Standardized class V cavities, prepared in human
extracted teeth, were filled with Premise (Kerr) composite. The
specimens were thermo cycled. The interfaces were examined by
Optical Coherence Tomography method (OCT) combined with the
confocal microscopy and fluorescence. The optical configuration
uses two single mode directional couplers with a superluminiscent
diode as the source at 1300 nm. The scanning procedure is similar to
that used in any confocal microscope, where the fast scanning is enface
(line rate) and the depth scanning is much slower (at the frame
rate). Gaps at the interfaces as well as inside the composite resin
materials were identified. OCT has numerous advantages which
justify its use in vivo as well as in vitro in comparison with
conventional techniques.
Abstract: Bonding has become a routine procedure in several
dental specialties – from prosthodontics to conservative dentistry and
even orthodontics. In many of these fields it is important to be able to
investigate the bonded interfaces to assess their quality. All currently
employed investigative methods are invasive, meaning that samples
are destroyed in the testing procedure and cannot be used again. We
have investigated the interface between human enamel and bonded
ceramic brackets non-invasively, introducing a combination of new
investigative methods – optical coherence tomography (OCT),
fluorescence OCT and confocal microscopy (CM). Brackets were
conventionally bonded on conditioned buccal surfaces of teeth. The
bonding was assessed using these methods. Three dimensional
reconstructions of the detected material defects were developed using
manual and semi-automatic segmentation. The results clearly prove
that OCT, fluorescence OCT and CM are useful in orthodontic
bonding investigations.