Abstract: This paper reports a new approach on identifying the
individuality of persons by using parametric classification of multiple
mental thoughts. In the approach, electroencephalogram (EEG)
signals were recorded when the subjects were thinking of one or
more (up to five) mental thoughts. Autoregressive features were
computed from these EEG signals and classified by Linear
Discriminant classifier. The results here indicate that near perfect
identification of 400 test EEG patterns from four subjects was
possible, thereby opening up a new avenue in biometrics.
Abstract: Detection of human emotions has many potential applications. One of application is to quantify attentiveness audience in order evaluate acoustic quality in concern hall. The subjective audio preference that based on from audience is used. To obtain fairness evaluation of acoustic quality, the research proposed system for multimodal emotion detection; one modality based on brain signals that measured using electroencephalogram (EEG) and the second modality is sequences of facial images. In the experiment, an audio signal was customized which consist of normal and disorder sounds. Furthermore, an audio signal was played in order to stimulate positive/negative emotion feedback of volunteers. EEG signal from temporal lobes, i.e. T3 and T4 was used to measured brain response and sequence of facial image was used to monitoring facial expression during volunteer hearing audio signal. On EEG signal, feature was extracted from change information in brain wave, particularly in alpha and beta wave. Feature of facial expression was extracted based on analysis of motion images. We implement an advance optical flow method to detect the most active facial muscle form normal to other emotion expression that represented in vector flow maps. The reduce problem on detection of emotion state, vector flow maps are transformed into compass mapping that represents major directions and velocities of facial movement. The results showed that the power of beta wave is increasing when disorder sound stimulation was given, however for each volunteer was giving different emotion feedback. Based on features derived from facial face images, an optical flow compass mapping was promising to use as additional information to make decision about emotion feedback.
Abstract: The ElectroEncephaloGram (EEG) is useful for
clinical diagnosis and biomedical research. EEG signals often
contain strong ElectroOculoGram (EOG) artifacts produced
by eye movements and eye blinks especially in EEG recorded
from frontal channels. These artifacts obscure the underlying
brain activity, making its visual or automated inspection
difficult. The goal of ocular artifact removal is to remove
ocular artifacts from the recorded EEG, leaving the underlying
background signals due to brain activity. In recent times,
Independent Component Analysis (ICA) algorithms have
demonstrated superior potential in obtaining the least
dependent source components. In this paper, the independent
components are obtained by using the JADE algorithm (best
separating algorithm) and are classified into either artifact
component or neural component. Neural Network is used for
the classification of the obtained independent components.
Neural Network requires input features that exactly represent
the true character of the input signals so that the neural
network could classify the signals based on those key
characters that differentiate between various signals. In this
work, Auto Regressive (AR) coefficients are used as the input
features for classification. Two neural network approaches
are used to learn classification rules from EEG data. First, a
Polynomial Neural Network (PNN) trained by GMDH (Group
Method of Data Handling) algorithm is used and secondly,
feed-forward neural network classifier trained by a standard
back-propagation algorithm is used for classification and the
results show that JADE-FNN performs better than JADEPNN.
Abstract: In single trial analysis, when using Principal
Component Analysis (PCA) to extract Visual Evoked Potential
(VEP) signals, the selection of principal components (PCs) is an
important issue. We propose a new method here that selects only
the appropriate PCs. We denote the method as selective eigen-rate
(SER). In the method, the VEP is reconstructed based on the rate
of the eigen-values of the PCs. When this technique is applied on
emulated VEP signals added with background
electroencephalogram (EEG), with a focus on extracting the
evoked P3 parameter, it is found to be feasible. The improvement
in signal to noise ratio (SNR) is superior to two other existing
methods of PC selection: Kaiser (KSR) and Residual Power (RP).
Though another PC selection method, Spectral Power Ratio (SPR)
gives a comparable SNR with high noise factors (i.e. EEGs), SER
give more impressive results in such cases. Next, we applied SER
method to real VEP signals to analyse the P3 responses for
matched and non-matched stimuli. The P3 parameters extracted
through our proposed SER method showed higher P3 response for
matched stimulus, which confirms to the existing neuroscience
knowledge. Single trial PCA using KSR and RP methods failed to
indicate any difference for the stimuli.
Abstract: A new approach based on the consideration that electroencephalogram (EEG) signals are chaotic signals was presented for automated diagnosis of electroencephalographic changes. This consideration was tested successfully using the nonlinear dynamics tools, like the computation of Lyapunov exponents. This paper presented the usage of statistics over the set of the Lyapunov exponents in order to reduce the dimensionality of the extracted feature vectors. Since classification is more accurate when the pattern is simplified through representation by important features, feature extraction and selection play an important role in classifying systems such as neural networks. Multilayer perceptron neural network (MLPNN) architectures were formulated and used as basis for detection of electroencephalographic changes. Three types of EEG signals (EEG signals recorded from healthy volunteers with eyes open, epilepsy patients in the epileptogenic zone during a seizure-free interval, and epilepsy patients during epileptic seizures) were classified. The selected Lyapunov exponents of the EEG signals were used as inputs of the MLPNN trained with Levenberg- Marquardt algorithm. The classification results confirmed that the proposed MLPNN has potential in detecting the electroencephalographic changes.
Abstract: This study is to investigate the electroencephalogram (EEG) differences generated from a normal and Alzheimer-s disease (AD) sources. We also investigate the effects of brain tissue distortions due to AD on EEG. We develop a realistic head model from T1 weighted magnetic resonance imaging (MRI) using finite element method (FEM) for normal source (somatosensory cortex (SC) in parietal lobe) and AD sources (right amygdala (RA) and left amygdala (LA) in medial temporal lobe). Then, we compare the AD sourced EEGs to the SC sourced EEG for studying the nature of potential changes due to sources and 5% to 20% brain tissue distortions. We find an average of 0.15 magnification errors produced by AD sourced EEGs. Different brain tissue distortion models also generate the maximum 0.07 magnification. EEGs obtained from AD sources and different brain tissue distortion levels vary scalp potentials from normal source, and the electrodes residing in parietal and temporal lobes are more sensitive than other electrodes for AD sourced EEG.