Abstract: An electrical apparatus for measuring moisture
content was developed by our laboratory and uses dependence of
electrical properties on water content in studied material. Error
analysis of the apparatus was run by measuring different volumes of
water in a simplified specimen, i.e. hollow plexiglass block, in order
to avoid as many side-effects as possible. Obtained data were
processed using both basic and advanced statistics and results were
compared with each other. The influence of water content on
accuracy of measured data was studied as well as the influence of
variation of apparatus' proper arrangement or factual methodics of its
usage. The overall coefficient of variation was 4%. There was no
trend found in results of error dependence on water content.
Comparison with current surveys led to a conclusion, that the studied
apparatus can be used for indirect measurement of water content in
porous materials, with expectable error and under known conditions.
Factual experiments with porous materials are not involved, but are
currently under investigation.
Abstract: Moisture is an important consideration in many
aspects ranging from irrigation, soil chemistry, golf course, corrosion
and erosion, road conditions, weather predictions, livestock feed
moisture levels, water seepage etc. Vegetation and crops always
depend more on the moisture available at the root level than on
precipitation occurrence. In this paper, design of an instrument is
discussed which tells about the variation in the moisture contents of
soil. This is done by measuring the amount of water content in soil by
finding the variation in capacitance of soil with the help of a
capacitive sensor. The greatest advantage of soil moisture sensor is
reduced water consumption. The sensor is also be used to set lower
and upper threshold to maintain optimum soil moisture saturation and
minimize water wilting, contributes to deeper plant root growth
,reduced soil run off /leaching and less favorable condition for insects
and fungal diseases. Capacitance method is preferred because, it
provides absolute amount of water content and also measures water
content at any depth.