Abstract: In this study, we develop a performance evaluation
model based on a multi-attribute utility approach aiming at reaching
the sustainable banking (SB) status. This model is built accounting
for various banks’ stakeholders in a win-win paradigm. In addition, it
offers the opportunity for adopting a global measure of performance
as an indication of a bank’s sustainability degree. This measure is
referred to as banking sustainability performance index (BSPI). This
index may constitute a basis for ranking banks. Moreover, it may
constitute a bridge between the assessment types of financial and
extra-financial rating agencies. A real application is performed on
three French banks.
Abstract: This paper presents a model predictive control (MPC)
of a utility interactive (UI) single phase inverter (SPI) for a
photovoltaic (PV) system at residential/distribution level. The
proposed model uses single-phase phase locked loop (PLL) to
synchronize SPI with the grid and performs MPC control in a dq
reference frame. SPI model consists of boost converter (BC),
maximum power point tracking (MPPT) control, and a full bridge
(FB) voltage source inverter (VSI). No PI regulators to tune and
carrier and modulating waves are required to produce switching
sequence. Instead, the operational model of VSI is used to synthesize
sinusoidal current and track the reference. Model is validated using a
three kW PV system at the input of UI-SPI in Matlab/Simulink.
Implementation and results demonstrate simplicity and accuracy, as
well as reliability of the model.
Abstract: This paper presents a hybrid three phase rectifier for
high power factor application. This rectifier is composed by zero
voltage transition (ZVT) and zero current transition (ZCT) boost
converter with three phase diode bridge rectifier, in parallel with a six
pulse three phase pulse width modulation (PWM) controlled rectifier.
The proposed topology is capable of high power factor with DC
output voltage regulation by providing sinusoidal input. Also, it
increases the overall efficiency of the new hybrid rectifier to 94.56%
and the total harmonic distortion of the hybrid structure varies from
0% to 16% at nominal output power. This topology was simulated in
MATLAB/SIMULINK environment and the output waveforms
presented with experimental result.
Abstract: Recently, to cope with the rapidly changing
construction trend with aging infrastructures, modular bridge
technology has been studied actively. Modular bridge is easily
constructed by assembling standardized precast structure members in
the field. It will be possible to construct rapidly and reduce
construction cost efficiently. However, the shape of the transverse
connection of T-type girder newly developed between the segmented
modules is not verified. Therefore, the verification of the connection
shape is needed. In this study, shape of the modular T-girder bridge
transverse connection was analyzed by finite element model that was
verified in study which was verified model of transverse connection
using Abaqus. Connection angle was chosen as the parameter. The
result of analyses showed that optimal value of angle is 130 degree.
Abstract: For Common R or R-L load to apply arbitrary voltage,
the bridge traditional inverters don’t have any difficulties by PWM
method. However for driving some piezoelectric actuator, arbitrary
voltage not a pulse but a steady voltage should be applied.
Piezoelectric load is considered as R-C load and its voltage does not
decrease even though the applied voltage decreases. Therefore it needs
some special inverter with circuit that can discharge the capacitive
energy. Especially for unidirectional arbitrary voltage driving like as
sine wave, it becomes more difficult problem. In this paper, a charge
and discharge circuit for unidirectional arbitrary voltage driving for
piezoelectric actuator is proposed. The circuit has charging and
discharging switches for increasing and decreasing output voltage.
With the proposed simple circuit, the load voltage can have any
unidirectional level with tens of bandwidth because the load voltage
can be adjusted by switching the charging and discharging switch
appropriately. The appropriateness is proved from the simulation of
the proposed circuit.
Abstract: The aim of this research is to design and implement line-tracking mobile robot. The robot must follow a line drawn on the floor with different color, avoids hitting moving object like another moving robot or walking people and achieves color sensing. The control system reacts by controlling each of the motors to keep the tracking sensor over the middle of the line. Proximity sensors used to avoid hitting moving objects that may pass in front of the robot. The programs have been written using micro c instructions, then converted into PIC16F887 ATmega48/88/168 microcontrollers counterparts. Practical simulations show that the walking robot accurately achieves line following action and exactly recognizes the colors and avoids any obstacle in front of it.
Abstract: Multilevel inverters such as flying capacitor, diodeclamped,
and cascaded H-bridge inverters are very popular
particularly in medium and high power applications. This paper
focuses on a cascaded H-bridge module using a single direct current
(DC) source in order to generate an 11-level output voltage. The
noble approach reduces the number of switches and gate drivers, in
comparison with a conventional method. The anticipated topology
produces more accurate result with an isolation transformer at high
switching frequency. Different modulation techniques can be used for
the multilevel inverter, but this work features modulation techniques
known as selective harmonic elimination (SHE).This modulation
approach reduces the number of carriers with reduction in Switching
Losses, Total Harmonic Distortion (THD), and thereby increasing
Power Quality (PQ). Based on the simulation result obtained, it
appears SHE has the ability to eliminate selected harmonics by
chopping off the fundamental output component. The performance
evaluation of the proposed cascaded multilevel inverter is performed
using PSIM simulation package and THD of 0.94% is obtained.
Abstract: Seismic retrofitting of important structures is essential in seismological active zones. The importance is doubled when it comes to some buildings like schools, hospitals, bridges etc. because they are required to continue their serviceability even after a major earthquake. Generally, seismic retrofitting codes have paid little attention to retrofitting of foundations due to its construction complexity. In this paper different methods for seismic retrofitting of tall buildings’ foundations will be discussed and evaluated. Foundations are considered in three different categories. First, foundations those are in danger of liquefaction of their underlying soil. Second, foundations located on slopes in seismological active regions. Third, foundations designed according to former design codes and may show structural defects under earthquake loads. After describing different methods used in different countries for retrofitting of the existing foundations in seismological active regions, comprehensive comparison between these methods with regard to the above mentioned categories is carried out. This paper gives some guidelines to choose the best method for seismic retrofitting of tall buildings’ foundations in retrofitting projects.
Abstract: Multilevel inverter is a promising inverter topology for high voltage and high power applications. This inverter synthesizes several different levels of DC voltages to produce a stepped AC output that approaches the pure sine waveform. The three different topologies, diode-clamped inverter, capacitor-clamped inverter and cascaded h-bridge multilevel inverter are widely used in these multilevel inverters. Among the three topologies, cascaded h-bridge multilevel inverter is more suitable for photovoltaic applications since each PV array can act as a separate dc source for each h-bridge module. This research especially focus on photovoltaic power source as input to the system and shows the potential of a Single Phase Cascaded H-bridge Eleven level inverter governed by the fuzzy logic controller to improve the power quality by reducing the total harmonic distortion at the output voltage. Hence the efficiency of the system will be improved. Simulation using MATLAB/SIMULINK has been done to verify the performance of cascaded h-bridge eleven level inverter using sinusoidal pulse width modulation technique. The simulated output shows very favorable result.
Abstract: The association between sensory problems and cognitive abilities has been studied in individuals with Autism Spectrum Disorders (ASDs). In this study, we used a Neuropsychological Test to evaluate memory and attention in ASDs children with sensory problems compared to the ASDs children without sensory problems. Four visual memory tests of Cambridge Neuropsychological Test Automated Battery (CANTAB) including Big/little circle (BLC), Simple Reaction Time (SRT) Intra /Extra dimensional set shift (IED), Spatial recognition memory (SRM), were administered to 14 ASDs children with sensory problems compared to 13 ASDs without sensory problems aged 3 to 12 with IQ of above 70. ASDs individuals with sensory problems performed worse than the ASDs group without sensory problems on comprehension, learning, reversal and simple reaction time tasks, and no significant difference between the two groups was recorded in terms of the visual memory and visual comprehension tasks. The findings of this study suggest that ASDs children with sensory problems are facing deficits in learning, comprehension, reversal, and speed of response to a stimulus.
Abstract: A cross-sectional survey to ascertain the capacity of laboratory persons in using ICTs was conducted in 15 Ugandan districts (July-August 2013). A self-administered questionnaire served as data collection tool, interview guide and observation checklist. 69 questionnaires were filled, 12 interviews conducted, 45 HC observed. SPSS statistics 17.0 and SAS 9.2 software were used for entry and analyses. 69.35% of participants find it difficult to access a computer at work. Of the 30.65% who find it easy to access a computer at work, a significant 21.05% spend 0 hours on a computer daily. 60% of the participants cannot access internet at work. Of the 40% who have internet at work, a significant 20% lack email address but 20% weekly read emails weekly and 48% daily. It is viable/feasible to pilot informatics projects as strategies to build bridges develop skills for e-health landscape in laboratory services with a bigger financial muscle.
Abstract: Structural lightweight concrete is used primarily to reduce the dead-load weight in concrete members such as floors in high-rise buildings and bridge decks. With given materials, it is generally desired to have the highest possible strength/unit weight ratio with the lowest cost of concrete. The work presented herein is part of an ongoing research project that investigates the properties of concrete mixes containing locally available Scoria lightweight aggregates and mineral admixtures. Properties considered included: workability, unit weight, compressive strength, and splitting tensile strength. Test results indicated that developing structural lightweight concretes (SLWC) using locally available Scoria lightweight aggregates and specific blends of silica fume and fly ash seems to be feasible. The stress-strain diagrams plotted for the structural LWC mixes developed in this investigation were comparable to a typical stress-strain diagram for normal weight concrete with relatively larger strain capacity at failure in case of LWC.
Abstract: Power quality in terms of power factor, THD and precisely regulated output voltage are the major key factors for efficient operation of power electronic converters. This paper presents an easy and effective active wave shaping control scheme for the pulsed input current drawn by the uncontrolled diode bridge rectifier thereby achieving power factor nearer to unity and also satisfying the THD specifications. It also regulates the output DC-bus voltage. CCM boost power factor correction with constant frequency operation features smaller inductor current ripple resulting in low RMS currents on inductor and switch thus leading to low electromagnetic interference. The objective of this work is to develop an active PFC control circuit using CCM boost converter implementing variable duty cycle control. The proposed scheme eliminates inductor current sensing requirements yet offering good performance and satisfactory results for maintaining the power quality. Simulation results have been presented which covers load changes also.
Abstract: Tsunami disaster poses a great threat to coastal infrastructures. Bridges without adequate provisions for earthquake and tsunami loading is generally vulnerable to tsunami attack. During the last two disastrous tsunami event (i.e. Indian Ocean and Japan Tsunami) a number of bridges were observed subsequent damages by tsunami waves. In this study, laboratory experiments were conducted to study the effects of perforations in bridge girder in force reduction. Results showed that significant amount of forces were reduced using perforations in girder. Approximately 10% to 18% force reductions were achieved by using about 16% perforations in bridge girder. Subsequent amount of force reductions revealed that perforations in girder are effective in reducing tsunami forces as perforations in girder let water to be passed through. Thus, less bridge damages are expected with the presence of perforations in girder during tsunami period.
Abstract: This paper is based on the bridgeless single-phase Ac–Dc Power Factor Correction (PFC) converters with Fuzzy Logic Controller. High frequency isolated Cuk converters are used as a modular dc-dc converter in Discontinuous Conduction Mode (DCM) of operation of Power Factor Correction. The aim of this paper is to simplify the program complexity of the controller by reducing the number of fuzzy sets of the Membership Functions (MFs) and to improve the efficiency and to eliminate the power quality problems. The output of Fuzzy controller is compared with High frequency triangular wave to generate PWM gating signals of Cuk converter. The proposed topologies are designed to work in Discontinuous Conduction Mode (DCM) to achieve a unity power factor and low total harmonic distortion of the input current. The Fuzzy Logic Controller gives additional advantages such as accurate result, uncertainty and imprecision and automatic control circuitry. Performance comparisons between the proposed and conventional controllers and circuits are performed based on circuit simulations.
Abstract: Bridge piers which are constructed in the track of high water rivers cause some variations in the flow patterns. This variation mostly is a result of the changes in river sections. Decreasing the river section, bridge piers significantly impress the flow patterns. Once the flow approaches the piers, the stream lines change their order, causing the appearance of different flow patterns around the bridge piers. New flow patterns are created following the geometry and the other technical characteristics of the piers. One of the most significant consequences of this event is the scour generated around the bridge piers which threatens the safety of the structure. In order to determine the properties of scour holes, to find maximum depth of the scour is an important factor. In this manuscript a numerical simulation of the scour around Marand-Soofian route bridge piers has been carried out via SSIIM 2.0 Software and the amount of maximum scour has been achieved subsequently. Eventually the methods for retrofitting of bridge piers against scours and also the methods for decreasing the amount of scour have been offered.
Abstract: The controller is used to improve the dynamic performance of DC-DC converter by achieving a robust output voltage against load disturbances. This paper presents the performance of PI and Fuzzy controller for a phase- shifted zero-voltage switched full-bridge PWM (ZVS FB- PWM) converters with a closed loop control. The proposed converter is regulated with minimum overshoot and good stability. In this paper phase-shift control method is used as an effective tool to reduce switching losses and duty cycle losses. A 1kW/100KHz dc/dc converter is simulated and analyzed using MATLAB. The circuit is simulated for static and dynamic load (DC motor). It has been observed that performance of converter with fuzzy controller is better than that of PI controller. An efficiency comparison of the converter with a reported topology has also been carried out.
Abstract: Aim: To investigate students’ perceptions of using e-models in an inquiry-based curriculum. Approach: 52 second-year dental students completed a pre- and post-test questionnaire relating to their perceptions of e-models and their use in inquiry-based learning. The pre-test occurred prior to any learning with e-models. The follow-up survey was conducted after one year's experience of using e-models. Results: There was no significant difference between the two sets of questionnaires regarding students’ perceptions of the usefulness of e-models and their willingness to use e-models in future inquiry-based learning. Most students preferred using both plaster models and e-models in tandem. Conclusion: Students did not change their attitude towards e-models and most of them agreed or were neutral that e-models are useful in inquiry-based learning. Whilst recognizing the utility of 3D models for learning, students' preference for combining these with solid models has implications for the development of haptic sensibility in an operative discipline.
Abstract: Floods are natural phenomena, which may turn into disasters causing widespread damage, health problems and even deaths. Nowadays, floods had become more serious and more frequent due to climatic changes. During flooding, discharge measurement still can be taken by standing on the bridge across the river using portable measurement instrument. However, it is too dangerous to get near to the river especially during high flood. Therefore, this study employs Particle Image Velocimetry (PIV) as a tool to measure the surface flow velocity. PIV is a image processing technique to track the movement of water from one point to another. The PIV codes are developed using Matlab. In this study, 18 ping pong balls were scattered over the surface of the drain and images were taken with a digital SLR camera. The images obtained were analyzed using the PIV code. Results show that PIV is able to produce the flow velocity through analyzing the series of images captured.
Abstract: Timber-concrete structures were recently introduced in Brazil as a viable option for bridge construction on side roads. Binding between timber and concrete is fundamentally important to assure the rigidity and performance of this structural system. The objective of this study was to assess the structural performance of a timber-concrete bridge prototype with width of 170cm and span of 400cm, whose binding among timber beams and concrete slabs was made with metal pins, obtained from CA 50 construction steel bars of 12.5mm diameter. It was possible to conclude, from the results obtained experimentally in laboratory, that the timber-concrete bridge prototype showed a good structural performance. This structural system provides an economical, rapid implementation solution, which may be used on side roads, favoring regional integration and agricultural production flow.