Abstract: With the rapid development of computer technology,
the design of computers and keyboards moves towards a trend of
slimness. The change of mobile input devices directly influences
users’ behavior. Although multi-touch applications allow entering
texts through a virtual keyboard, the performance, feedback, and
comfortableness of the technology is inferior to traditional keyboard,
and while manufacturers launch mobile touch keyboards and
projection keyboards, the performance has not been satisfying.
Therefore, this study discussed the design factors of slim
pressure-sensitive keyboards. The factors were evaluated with an
objective (accuracy and speed) and a subjective evaluation
(operability, recognition, feedback, and difficulty) depending on the
shape (circle, rectangle, and L-shaped), thickness (flat, 3mm, and
6mm), and force (35±10g, 60±10g, and 85±10g) of the keyboard.
Moreover, MANOVA and Taguchi methods (regarding
signal-to-noise ratios) were conducted to find the optimal level of each
design factor. The research participants, by their typing speed (30
words/ minute), were divided in two groups. Considering the
multitude of variables and levels, the experiments were implemented
using the fractional factorial design. A representative model of the
research samples were established for input task testing. The findings
of this study showed that participants with low typing speed primarily
relied on vision to recognize the keys, and those with high typing
speed relied on tactile feedback that was affected by the thickness and
force of the keys. In the objective and subjective evaluation, a
combination of keyboard design factors that might result in higher
performance and satisfaction was identified (L-shaped, 3mm, and
60±10g) as the optimal combination. The learning curve was analyzed
to make a comparison with a traditional standard keyboard to
investigate the influence of user experience on keyboard operation.
The research results indicated the optimal combination provided input
performance to inferior to a standard keyboard. The results could serve
as a reference for the development of related products in industry and
for applying comprehensively to touch devices and input interfaces
which are interacted with people.
Abstract: From a theoretical perspective, electric buses can be more sustainable and can be cheaper than fossil fuelled buses in city traffic. The authors have not found other studies based on actual urban public transport in Swedish winter climate. Further on, noise measurements from buses for the European market were found old. The aims of this follow-up study was therefore to test and possibly verify in a real-life environment how energy efficient and silent electric buses are, and then conclude on if electric buses are preferable to use in public transport. The Ebusco 2.0 electric bus, fitted with a 311 kWh battery pack, was used and the tests were carried out during November 2014-April 2015 in eight municipalities in the south of Sweden. Six tests took place in urban traffic and two took place in more of a rural traffic setting. The energy use for propulsion was measured via logging of the internal system in the bus and via an external charging meter. The average energy use turned out to be 8% less (0,96 kWh/km) than assumed in the earlier theoretical study. This rate allows for a 320 km range in public urban traffic. The interior of the bus was kept warm by a diesel heater (biodiesel will probably be used in a future operational traffic situation), which used 0,67 kWh/km in January. This verified that electric buses can be up to 25% cheaper when used in public transport in cities for about eight years. The noise was found to be lower, primarily during acceleration, than for buses with combustion engines in urban bus traffic. According to our surveys, most passengers and drivers appreciated the silent and comfortable ride and preferred electric buses rather than combustion engine buses. Bus operators and passenger transport executives were also positive to start using electric buses for public transport. The operators did however point out that procurement processes need to account for eventual risks regarding this new technology, along with personnel education. The study revealed that it is possible to establish a charging infrastructure for almost all studied bus lines. However, design of a charging infrastructure for each municipality requires further investigations, including electric grid capacity analysis, smart location of charging points, and tailored schedules to allow fast charging. In conclusion, electric buses proved to be a preferable alternative for all stakeholders involved in public bus transport in the studied municipalities. However, in order to electric buses to be a prominent support for sustainable development, they need to be charged either by stand-alone units or via an expansion of the electric grid, and the electricity should be made from new renewable sources.
Abstract: Recently, the world main problem is a global warming and climate change affecting both outdoor and indoor environments, especially the air quality (AQ) as a result of vast migration of people from rural areas to urban areas. Therefore, cities became more crowded and denser from an irregular population increase, along with increasing urbanization caused many problems for the environment such as increasing the land prices, changes in life style, and the new buildings are not adapted to the climate producing uncomfortable and unhealthy indoor building conditions. As interior environments are the places that create the most intimate relationship with the user. Consequently, the indoor environment quality (IEQ) for buildings became uncomfortable and unhealthy for its occupants. The symptoms commonly associated with poor indoor environment such as itchy, headache, fatigue, and respiratory complaints such as cough and congestion, etc. The symptoms tend to improve over time or even disappear when people are away from the building. Therefore, designing a healthy indoor environment to fulfill human needs is the main concern for architects and interior designer. However, this research explores how occupant expectations and environmental attitudes may influence occupant health and satisfaction within the context of the indoor environment. In doing so, it reviews and contributes to the methods and tools used to evaluate only the indoor environment quality (IEQ) components of building performance. Its main aim is to review the literature on indoor human comfort. This is followed by a review of previous papers published related to human comfort. Finally, this paper will provide possible approaches in design level of healthy buildings.
Abstract: In this paper, an attempt has been made to analyze the effect of wall window orientation on Daylight Illuminance Ratio (DIR) and energy saving in a building known as “SODHA BERS COMPLEX (SBC)” at Varanasi, UP, India. The building has been designed incorporating all passive concepts for thermal comfort as well daylighting concepts to maximize the use of natural daylighting for the occupants in the day to day activities. The annual average DIR and the energy saving has been estimated by using the DIR model for wall window with different orientations under clear sky condition. It has been found that for south oriented window the energy saving per square meter is more compared to the other orientations due to the higher level of solar insolation for the south window in northern hemisphere whereas energy saving potential is minimum for north oriented wall window. The energy saving potential was 26%, 81% and 51% higher for east, south and west oriented window in comparison to north oriented window. The average annual DIR has same trends of variation as the annual energy saving and it is maximum for south oriented window and minimum for north oriented window.
Abstract: Recent progress in the next generation of automobile
technology is geared towards incorporating information technology
into cars. Collectively called smart cars are bringing intelligence to
cars that provides comfort, convenience and safety. A branch of smart
cars is connected-car system. The key concept in connected-cars is the
sharing of driving information among cars through decentralized
manner enabling collective intelligence. This paper proposes a
foundation of the information model that is necessary to define the
driving information for smart-cars. Road conditions are modeled
through a unique data structure that unambiguously represent the time
variant traffics in the streets. Additionally, the modeled data structure
is exemplified in a navigational scenario and usage using UML.
Optimal driving route searching is also discussed using the proposed
data structure in a dynamically changing road conditions.
Abstract: The present paper examines the impact noise
transmission through some floor building assemblies. The Acoubat
software numerical simulation has been used to simulate the impact
noise transmission through different floor configurations used in
Algerian construction mode. The results are compared with the
available measurements. We have developed two experimental
methods, i) field method, and ii) laboratory method using Brüel and
Kjær equipments. The results show that the different cases of floor
configurations need some improvement to ensure the acoustic
comfort in the receiving apartment. The recommended value of the
impact sound level in the receiving room should not exceed 58 dB.
The important results obtained in this paper can be used as platform
to improve the Algerian building acoustic regulation aimed at the
construction of the multi-storey residential building.
Abstract: With 40% of total world energy consumption,
building systems are developing into technically complex large
energy consumers suitable for application of sophisticated power
management approaches to largely increase the energy efficiency
and even make them active energy market participants. Centralized
control system of building heating and cooling managed by
economically-optimal model predictive control shows promising
results with estimated 30% of energy efficiency increase. The research
is focused on implementation of such a method on a case study
performed on two floors of our faculty building with corresponding
sensors wireless data acquisition, remote heating/cooling units and
central climate controller. Building walls are mathematically modeled
with corresponding material types, surface shapes and sizes. Models
are then exploited to predict thermal characteristics and changes in
different building zones. Exterior influences such as environmental
conditions and weather forecast, people behavior and comfort
demands are all taken into account for deriving price-optimal climate
control. Finally, a DC microgrid with photovoltaics, wind turbine,
supercapacitor, batteries and fuel cell stacks is added to make the
building a unit capable of active participation in a price-varying
energy market. Computational burden of applying model predictive
control on such a complex system is relaxed through a hierarchical
decomposition of the microgrid and climate control, where the
former is designed as higher hierarchical level with pre-calculated
price-optimal power flows control, and latter is designed as lower
level control responsible to ensure thermal comfort and exploit
the optimal supply conditions enabled by microgrid energy flows
management. Such an approach is expected to enable the inclusion
of more complex building subsystems into consideration in order to
further increase the energy efficiency.
Abstract: An analysis of the air tightness level is performed on a representative sample of school classrooms in Southern Spain, which allows knowing the infiltration level of these classrooms, mainly through its envelope, which can affect both energy demand and occupant's thermal comfort. By using a pressurization/depressurization equipment (Blower-Door test), a characterization of 45 multipurpose classrooms have been performed in nine non-university educational institutions of the main climate zones of Southern Spain. In spite of having two doors and a high ratio between glass surface and outer surface, it is possible to see in these classrooms that there is an adequate level of airtightness, since all the n50 values obtained are lower than 9.0 ACH, with an average value around 7.0 ACH.
Abstract: The simulation in wind tunnel is used thoroughly to model real situations of drainages of air. Besides the automotive industry, a great number of applications can be numbered: dispersion of pollutant, studies of pedestrians’ comfort, and dispersion of particles. This work had the objective of visualizing the characteristics aerodynamics of two automobiles in different ways. To accomplish that drainage of air a fan that generated a speed exists (measured with anemometer of hot thread) of 4,1m/s and 4,95m/s. To visualize the path of the air through the cars, in the wind tunnel, smoke was used, obtained with it burns of vegetable oil. For “to do smoke” vegetable oil was used, that was burned for a tension of 20V generated by a thread of 2,5mm. The cars were placed inside of the wind tunnel with the drainage of “air-smoke” and photographed, registering like this the path lines around them, in the 3 different speeds.
Abstract: In this work, by replacing the traditional solid spokes with colloidal spokes, a vehicle wheel with a built-in suspension structure is proposed. Following the background and description of the wheel system, firstly, a vibration model of the wheel equipped with colloidal spokes is proposed, and based on such model the equivalent damping coefficients and spring constants are identified. Then, a modified model of a quarter-vehicle moving on a rough pavement is proposed in order to estimate the transmissibility of vibration from the road roughness to vehicle body. In the end, the optimal design of the colloidal spokes and the optimum number of colloidal spokes are decided in order to minimize the transmissibility of vibration, i.e., to maximize the ride comfort of the vehicle.
Abstract: This paper concentrates on the sustainable traditional
architecture and urban planning in hot-humid regions of Iran. In a
vast country such as Iran with different climatic zones traditional
builders have presented series of logical solutions for human comfort.
The aim of this paper is to demonstrate traditional architecture in hothumid
climate of Iran as a sample of sustainable architecture. Iranian
traditional architecture has been able to response to environmental
problems for a long period of time. Its features are based on climatic
factors, local construction materials of hot-humid regions and culture.
This paper concludes that Iranian traditional architecture can be
addressed as a sustainable architecture.
Abstract: The aim of sustainable architecture is to design
buildings with the least adverse effects on the environment and
provide better conditions for people. What building forms make the
best use of land? This question was addressed in the late 1960s at the
center of Land Use and Built Form Studies in Cambridge. This led to
a number of influential papers which had a great influence on the
practice of urban design. This paper concentrates on the results of
sustainability caused by climatic conditions in Iranian traditional
architecture in hot-arid regions. As people spent a significant amount
of their time in houses, it was very important to have such houses to
fulfill their needs physically and spiritually as well as satisfying their
cultural and religious aspects of their lifestyles. In a vast country such
as Iran with different climatic zones, traditional builders have
presented series of logical solutions for human comfort. These
solutions have been able to response to the environmental problems
for a long period of time. As a result, by considering the experience
in traditional architecture of hot–arid climate in Iran, it is possible to
attain sustainable architecture.
Abstract: The garment manufacturing industry involves
sequential processes that are subjected to uncontrollable variations.
The industry depends on the skill of labour in handling the varieties
of fabrics and accessories, machines, as well as complicated sewing
operation. Due to these reasons, garment manufacturers have created
systems to monitor and to control the quality of the products on a
regular basis by conducting quality approaches to minimize variation.
With that, the aim of this research has been to ascertain the quality
approaches deployed by Malaysian garment manufacturers in three
key areas - quality systems and tools; quality control and types of
inspection; as well as sampling procedures chosen for garment
inspection. Besides, the focus of this research was to distinguish the
quality approaches adopted by companies that supplied finished
garments to both domestic and international markets. Feedback from
each company representative has been obtained via online survey,
which comprised of five sections and 44 questions on the
organizational profile and the quality approaches employed in the
garment industry. As a result, the response rate was 31%. The results
revealed that almost all companies have established their own
mechanism of process control by conducting a series of quality
inspections for daily production, either it was formally set up or
otherwise. In addition, quality inspection has been the predominant
quality control activity in the garment manufacturing, while the level
of complexity of these activities was substantially dictated by the
customers. Moreover, AQL-based sampling was utilized by
companies dealing with exports, whilst almost all the companies that
only concentrated on the domestic market were comfortable using
their own sampling procedures for garment inspection. Hence, this
research has provided insights into the implementation of a number
of quality approaches that were perceived as important and useful in
the garment manufacturing sector, which is truly labour-intensive.
Abstract: Myocardial infarction is one of the leading causes of
death in the world. Some of these deaths occur even before the
patient reaches the hospital. Myocardial infarction occurs as a result
of impaired blood supply. Because the most of these deaths are due to
coronary artery disease, hence the awareness of the warning signs of
a heart attack is essential. Some heart attacks are sudden and intense,
but most of them start slowly, with mild pain or discomfort, then
early detection and successful treatment of these symptoms is vital to
save them. Therefore, importance and usefulness of a system
designing to assist physicians in early diagnosis of the acute heart
attacks is obvious. The main purpose of this study would be to enable patients to
become better informed about their condition and to encourage them
to seek professional care at an earlier stage in the appropriate
situations. For this purpose, the data were collected on 711 heart
patients in Iran hospitals. 28 attributes of clinical factors can be
reported by patients; were studied. Three logistic regression models
were made on the basis of the 28 features to predict the risk of heart
attacks. The best logistic regression model in terms of performance
had a C-index of 0.955 and with an accuracy of 94.9%. The variables,
severe chest pain, back pain, cold sweats, shortness of breath, nausea
and vomiting, were selected as the main features.
Abstract: With the increasing population and intensive land use,
huge traffic demand is generating worldwide both in developing and
developed countries. As a developing country, Bangladesh is also
facing the same problem in recent years by producing huge numbers
of daily trips. As a matter of fact, extensive traffic demand is
increasing day by day. Also, transport system in Dhaka is
heterogeneous, reflecting the heterogeneity in the socio-economic
and land use patterns. Trips produced here are for different purposes
such as work, business, educational etc. Due to the significant
concentration of educational institutions a large share of the trips are
generated by educational purpose. And one of the major percentages
of educational trips is produced by university going students and
most of them are travelled by car, bus, train, taxi, rickshaw etc. The
aim of the study was to find out the university students’ perception on
public transit ridership. A survey was conducted among 330 students
from eight different universities. It was found out that 26% of the
trips produced by university going students are travelled by public
bus service and only 5% are by train. Percentage of car share is 16%
and 12% of the trips are travelled by private taxi. It has been
observed from the study, students those who prefer bus instead of
other options, 42 percent of their family resides outside Dhaka. And
those who prefer walking, of them, over 40 percent students’ family
reside outside of Dhaka and of them over 85 percent students have a
tendency to live in a mess. On the contrary, students travelling by car
represents, most of their family reside in Dhaka. The study also
revealed that the most important reason that restricts students not to
use public transit is poor service. Negative attitudes such as
discomfort, uneasiness in using public transit also reduces the usage
of public transit. The poor waiting area is another major cause of not
using public transit. Insufficient security also plays a significant role
in not using public transit. On the contrary, the fare is not a problem
for students those who use public transit as a mode of transportation.
Students also think stations are not far away from their home or
institution and they do not need to wait long for the buses or trains. It
was also found accessibility to public transit is moderate.
Abstract: This paper aims to determine Fundamental Natural
Frequency (FNF) of a structural composite floor system known as
Chromite. To achieve this purpose, FNFs of studied panels are
determined by development of Finite Element Models (FEMs) in
ABAQUS program. American Institute of Steel Construction (AISC)
code in Steel Design Guide Series 11 presents a fundamental formula
to calculate FNF of a steel framed floor system. This formula has
been used to verify results of the FEMs. The variability in the FNF of
the studied system under various parameters such as dimensions of
floor, boundary conditions, rigidity of main and secondary beams
around the floor, thickness of concrete slab, height of composite
joists, distance between composite joists, thickness of top and bottom
flanges of the open web steel joists, and adding tie beam
perpendicular on the composite joists, is determined. The results
show that changing in dimensions of the system, its boundary
conditions, rigidity of main beam, and also adding tie beam,
significant changes the FNF of the system up to 452.9%, 50.8%, -
52.2%, %52.6%, respectively. In addition, increasing thickness of
concrete slab increases the FNF of the system up to 10.8%.
Furthermore, the results demonstrate that variation in rigidity of
secondary beam, height of composite joist, and distance between
composite joists, and thickness of top and bottom flanges of open
web steel joists insignificant changes the FNF of the studied system
up to -0.02%, -3%, -6.1%, and 0.96%, respectively. Finally, the
results of this study help designer predict occurrence of resonance,
comfortableness, and design criteria of the studied system.
Abstract: Home Energy Management System (HEMS), which makes the residential consumers, contribute to the demand response is attracting attention in recent years. An aim of HEMS is to minimize their electricity cost by controlling the use of their appliances according to electricity price. The use of appliances in HEMS may be affected by some conditions such as external temperature and electricity price. Therefore, the user’s usage pattern of appliances should be modeled according to the external conditions, and the resultant usage pattern is related to the user’s comfortability on use of each appliances. This paper proposes a methodology to model the usage pattern based on the historical data with the copula function. Through copula function, the usage range of each appliance can be obtained and is able to satisfy the appropriate user’s comfort according to the external conditions for next day. Within the usage range, an optimal scheduling for appliances would be conducted so as to minimize an electricity cost with considering user’s comfort. Among the home appliance, electric heater (EH) is a representative appliance, which is affected by the external temperature. In this paper, an optimal scheduling algorithm for an electric heater (EH) is addressed based on the method of branch and bound. As a result, scenarios for the EH usage are obtained according to user’s comfort levels and then the residential consumer would select the best scenario. The case study shows the effects of the proposed algorithm compared with the traditional operation of the EH, and it represents impacts of the comfort level on the scheduling result.
Abstract: This study was carried out for an underground subway station at Seoul Metro, Korea. The optimal set-points of the ventilation control system are determined every 3 hours, then, the ventilation controller adjusts the ventilation fan speed according to the optimal set-point changes. Compared to manual ventilation system which is operated irrespective of the OAQ, the IDP-based ventilation control system saves 3.7% of the energy consumption. Compared to the fixed set-point controller which is operated irrespective of the IAQ diurnal variation, the IDP-based controller shows better performance with a 2% decrease in energy consumption, maintaining the comfortable IAQ range inside the station.
Abstract: Below-knee amputees commonly experience
asymmetrical gait patterns. It is generally believed that ischemia is
related to the formation of pressure sores due to uneven distribution
of forces. Micro-vascular responses can reveal local malnutrition.
Changes in local skin blood supply under various external loading
conditions have been studied for a number of years. Radionuclide
clearance, photo-plethysmography, trans-cutaneous oxygen tension
along with other studies showed that the blood supply would be
influenced by the epidermal forces, and the rate and the amount of
blood supply would decrease with increased epidermal loads being
shear forces or normal forces. Several cases of socket designs were
investigated using Finite Element Model (FEM) and Design of
Experiment (DOE) to increase flexibility and minimize the pressure
at the limb/socket interface using ultra high molecular weight
polyethylene (UHMWPE) and polyamide 6 (PA6) or Duraform. The
pressure reliefs at designated areas where reducing thickness is
involved are seen to be critical in determination of amputees’ comfort
and are very important to clinical applications. Implementing a hole
between the Patellar Tendon (PT) and Distal Tibia (DT) would
decrease stiffness and increase prosthesis range of motion where
flexibility is needed. In addition, displacement and prosthetic energy
storage increased without compromising mechanical efficiency and
prosthetic design integrity.
Abstract: High frequency automotive interior noise above 500
Hz considerably affects automotive passenger comfort. To reduce this
noise, sound insulation material is often laminated on body panels or
interior trim panels. For a more effective noise reduction, the sound
reduction properties of this laminated structure need to be estimated.
We have developed a new calculate tool that can roughly calculate the
sound absorption and insulation properties of laminate structure and
handy for designers. In this report, the outline of this tool and an
analysis example applied to floor mat are introduced.