Volume:8, Issue: 12, 2014 Page No: 1244 - 1247
ISSN: 2415-1734
This paper present the experimental work of double
unit tunnel form building (TFB) subjected to in-plane lateral cyclic
loading. A one third scale of 3-storey double unit of TFB is tested
until its strength degradation. Then, the TFB is repaired and
retrofitted using additional shear wall, steel angle and CFRP sheet.
The crack patterns, lateral strength, stiffness, ductility and equivalent
viscous damping (EVD) were analyzed and compared before and
after repair and retrofit. The result indicates that the lateral strength
increases by 22% in pushing and 27% in pulling direction. Moreover,
the stiffness and ductility obtained before and after retrofit increase
tremendously by 87.87% and 39.66%, respectively. Meanwhile, the
energy absorption measured by equivalent viscous damping obtained
after retrofit increase by 12.34% in pulling direction. It can be
concluded that the proposed retrofit method is capable to increase the
lateral strength capacity, stiffness and energy absorption of double
unit TFB.