Volume:8, Issue: 9, 2014 Page No: 1003 - 1011
ISSN: 2415-1734
Heating, cooling and lighting appliances in buildings
account for more than one third of the world’s primary energy
demand. Therefore, main components of the building heating systems
play an essential role in terms of energy consumption. In this context,
efficient energy and exergy utilization in HVAC-R systems has been
very essential, especially in developing energy policies towards
increasing efficiencies. The main objective of the present study is to
assess the performance of a family house with a volume of 326.7 m3
and a net floor area of 121 m2, located in the city of Izmir, Turkey in
terms of energetic, exergetic and sustainability aspects. The indoor
and exterior air temperatures are taken as 20°C and 1°C, respectively.
In the analysis and assessment, various metrics (indices or indicators)
such as exergetic efficiency, exergy flexibility ratio and sustainability
index are utilized. Two heating options (Case 1: condensing boiler
and Case 2: air heat pump) are considered for comparison purposes.
The total heat loss rate of the family house is determined to be
3770.72 W. The overall energy efficiencies of the studied cases are
calculated to be 49.4% for Case 1 and 54.7% for Case 2. The overall
exergy efficiencies, the flexibility factor and the sustainability index
of Cases 1 and 2 are computed to be around 3.3%, 0.17 and 1.034,
respectively.