Volume:8, Issue: 11, 2014 Page No: 1390 - 1394
ISSN: 2517-9934
Theoretical optimization of a copper-water negative
inclination heat pipe with internal composite wick structure had been
performed, regarding a new introduced parameter: the ratio between
the coarse mesh wraps and the fine mesh wraps of the composite
wick. Since in many cases, the design of a heat pipe matches specific
thermal requirements and physical limitations, this work
demonstrates the optimization of a 1m length, 8mm internal diameter
heat pipe without an adiabatic section, at a negative inclination angle
of -10º. The optimization is based on a new introduced parameter, LR:
the ratio between the coarse mesh wraps and the fine mesh wraps.