Abstract: In a liberalized electricity market, it is not surprising
that different customers require different power quality (PQ) levels at
different price. Power quality related to several power disturbances is
described by many parameters, so how to define a comprehensive
hierarchy evaluation system of power quality (PQCHES) has become
a concerned issue. In this paper, based on four electromagnetic
compatibility (EMC) levels, the numerical range of each power
disturbance is divided into five grades (Grade I –Grade V), and the
“barrel principle" of power quality is used for the assessment of
overall PQ performance with only one grade indicator. A case study
based on actual monitored data of PQ shows that the site PQ grade
indicates the electromagnetic environment level and also expresses the
characteristics of loads served by the site.
The shortest plank principle of PQ barrel is an incentive
mechanism, which can combine with the rewards/penalty mechanism
(RPM) of consumed energy “on quality demand", to stimulate utilities
to improve the overall PQ level and also stimulate end-user more
“smart" under the infrastructure of future SmartGrid..
Abstract: The ferroelectric behavior of barium strontium
titanate (BST) in thin film form has been investigated in order to
study the possibility of using BST for ferroelectric gate-field effect
transistor (FeFET) for memory devices application. BST thin films
have been fabricated as Al/BST/Pt/SiO2/Si-gate configuration. The
variation of the dielectric constant (ε) and tan δ with frequency have
been studied to ensure the dielectric quality of the material. The
results show that at low frequencies, ε increases as the Ba content
increases, whereas at high frequencies, it shows the opposite
variation, which is attributed to the dipole dynamics. tan δ shows low
values with a peak at the mid-frequency range. The ferroelectric
behavior of the Al/BST/Pt/SiO2/Si has been investigated using C-V
characteristics. The results show that the strength of the ferroelectric
hysteresis loop increases as the Ba content increases; this is attributed
to the grain size and dipole dynamics effect.
Abstract: Kuwait-s electric power system is vertically integrated
organization owned and operated by the government. For more than
five decades, the government of Kuwait has provided relatively
reliable electric services to consumers with subsidized electric
service fees. Given the country-s rapid socio-economical
development and consequently the increase of electricity demand, a
question that inflicts itself: Is it necessary to reform the power system
to face the fast growing demand? This paper recommends that the
government should consider the private sector as a partner in
operating the power system. Therefore, power system restructuring is
needed to allow such partnership. There are challenges that prevent
such restructuring. Abstract recommendations toward resolving these
challenges are proposed.
Abstract: In this paper, we propose a novel metal oxide
semiconductor field effect transistor with L-shaped channel structure
(LMOS), and several type of L-shaped structures are also designed,
studied and compared with the conventional MOSFET device for the
same average gate length (Lavg). The proposed device electrical
characteristics are analyzed and evaluated by three dimension (3-D)
ISE-TCAD simulator. It can be confirmed that the LMOS devices
have higher on-state drain current and both lower drain-induced
barrier lowering (DIBL) and subthreshold swing (S.S.) than its
conventional counterpart has. In addition, the transconductance and
voltage gain properties of the LMOS are also improved.
Abstract: Nano sized zirconium dioxide in monoclinic phase (m-ZrO2) has been synthesized in pure form through co-precipitation processing at different calcination temperatures and has been characterized by several techniques such as XRD, FT-IR, UV-Vis Spectroscopy and SEM. The dielectric and capacitance values of the pelletized samples have been examined at room temperature as the functions of frequency. The higher dielectric constant value of the sample having larger grain size proves the strong influence of grain size on the dielectric constant.
Abstract: Applying corona wind as a novel technique can lead
to a great level of heat and mass transfer augmentation by using very
small amount of energy. Enhancement of forced flow evaporation
rate by applying electric field (corona wind) has been experimentally
evaluated in this study. Corona wind produced by a fine wire
electrode which is charged with positive high DC voltage impinges
to water surface and leads to evaporation enhancement by disturbing
the saturated air layer over water surface. The study was focused on
the effect of corona wind velocity, electrode spacing and air flow
velocity on the level of evaporation enhancement. Two sets of
experiments, i.e. with and without electric field, have been
conducted. Data obtained from the first experiment were used as
reference for evaluation of evaporation enhancement at the presence
of electric field. Applied voltages ranged from corona threshold
voltage to spark over voltage at 1 kV increments. The results showed
that corona wind has great enhancement effect on water evaporation
rate, but its effectiveness gradually diminishes by increasing air flow
velocity. Maximum enhancements were 7.3 and 3.6 for air velocities
of 0.125 and 1.75 m/s, respectively.
Abstract: Recently, distributed generation technologies have received much attention for the potential energy savings and reliability assurances that might be achieved as a result of their widespread adoption. Fueling the attention have been the possibilities of international agreements to reduce greenhouse gas emissions, electricity sector restructuring, high power reliability requirements for certain activities, and concern about easing transmission and distribution capacity bottlenecks and congestion. So it is necessary that impact of these kinds of generators on distribution feeder reconfiguration would be investigated. This paper presents an approach for distribution reconfiguration considering Distributed Generators (DGs). The objective function is summation of electrical power losses A Tabu search optimization is used to solve the optimal operation problem. The approach is tested on a real distribution feeder.
Abstract: This study investigates a voltage-controllable liquid crystals lens with a Fresnel zone electrode. When applying a proper voltage on the liquid crystal cell, a Fresnel-zone-distributed electric field is induced to direct liquid crystals aligned in a concentric structure. Owing to the concentrically aligned liquid crystals, a Fresnel lens is formed. We probe the Fresnel liquid crystal lens using a polarized incident beam with a wavelength of 632.8 nm, finding that the diffraction efficiency depends on the applying voltage. A remarkable diffraction efficiency of ~39.5 % is measured at the voltage of 0.9V. Additionally, a dual focus lens is fabricated by attaching a plane-convex lens to the Fresnel liquid crystals cell. The Fresnel LC lens and the dual focus lens may be applied for DVD/CD pick-up head, confocal microscopy system, or electrically-controlling optical systems.
Abstract: Artificial atoms are growing fields of interest due to their physical and optoelectronicapplications. The absorption spectra of the proposed artificial atom inpresence of Tera-Hertz field is investigated theoretically. We use the non-perturbativeFloquet theory and finite difference method to study the electronic structure of ArtificialAtom. The effect of static electric field on the energy levels of artificial atom is studied.The effect of orientation of static electric field on energy levels and diploe matrix elementsis also highlighted.
Abstract: Analytical investigation of the free vibration behavior
of circular functionally graded (FG) plates integrated with two
uniformly distributed actuator layers made of piezoelectric (PZT4)
material on the top and bottom surfaces of the circular FG plate
based on the classical plate theory (CPT) is presented in this paper.
The material properties of the functionally graded substrate plate are
assumed to be graded in the thickness direction according to the
power-law distribution in terms of the volume fractions of the
constituents and the distribution of electric potential field along the
thickness direction of piezoelectric layers is simulated by a quadratic
function. The differential equations of motion are solved analytically
for clamped edge boundary condition of the plate. The detailed
mathematical derivations are presented and Numerical investigations
are performed for FG plates with two surface-bonded piezoelectric
layers. Emphasis is placed on investigating the effect of varying the
gradient index of FG plate on the free vibration characteristics of the
structure. The results are verified by those obtained from threedimensional
finite element analyses.
Abstract: The condition of lightning surge causes the traveling waves and the temporary increase in voltage in the transmission line system. Lightning is the most harmful for destroying the transmission line and setting devices so it is necessary to study and analyze the temporary increase in voltage for designing and setting the surge arrester. This analysis describes the figure of the lightning wave in transmission line with 115 kV voltage level in Thailand by using ATP/EMTP program to create the model of the transmission line and lightning surge. Because of the limit of this program, it must be calculated for the geometry of the transmission line and surge parameter and calculation in the manual book for the closest value of the parameter. On the other hand, for the effects on surge protector when the lightning comes, the surge arrester model must be right and standardized as metropolitan electrical authority's standard. The candidate compared the real information to the result from calculation, also. The results of the analysis show that the temporary increase in voltage value will be rise to 326.59 kV at the line which is done by lightning when the surge arrester is not set in the system. On the other hand, the temporary increase in voltage value will be 182.83 kV at the line which is done by lightning when the surge arrester is set in the system and the period of the traveling wave is reduced, also. The distance for setting the surge arrester must be as near to the transformer as possible. Moreover, it is necessary to know the right distance for setting the surge arrester and the size of the surge arrester for preventing the temporary increase in voltage, effectively.
Abstract: One way for optimum loading of overdimensioning
conveyers is speed (capacity) decrement, with attention for
production capabilities and demands. At conveyers which drives with
three phase slip-ring induction motor, technically reasonable solution
for conveyer (driving motors) speed regulation is using constant
torque subsynchronous cascade with static semiconductor converter
and transformer for energy reversion to the power network. In the
paper is described mathematical model for parameter calculation of
two-motors 6 kV subsynchronous cascade. It is also demonstrated
that applying of this cascade gave several good properties, foremost
in electrical energy saving, also in improving of other energy
indexes, and finally that results in cost reduction of complete
electrical motor drive.
Abstract: This study investigates the electrical performance of a
planar solid oxide fuel cell unit with cross-flow configuration when the fuel utilization gets higher and the fuel inlet flow are non-uniform.
A software package in this study solves two-dimensional,
simultaneous, partial differential equations of mass, energy, and
electro-chemistry, without considering stack direction variation. The
results show that the fuel utilization increases with a decrease in the molar flow rate, and the average current density decreases when the
molar flow rate drops. In addition, non-uniform Pattern A will induce more severe happening of non-reaction area in the corner of the fuel
exit and the air inlet. This non-reaction area deteriorates the average
current density and then deteriorates the electrical performance to –7%.
Abstract: Lighting upgrades involve relatively lower costs which
allow the benefits to be spread more widely than is possible with any
other energy efficiency measure. In order to popularize the adoption of
CFL in Taiwan, the authority proposes to implement a new energy efficient lamp comparative label system. The current study was
accordingly undertaken to investigate the factors affecting the performance and the deviation of actual and labeled performance of
commercially available integrated CFLs. In this paper, standard test
methods to determine the electrical and photometric performances of
CFL were developed based on CIE 84-1989 and CIE 60901-1987,
then 55 selected CFLs from market were tested. The results show that
with higher color temperature of CFLs lower efficacy are achieved. It
was noticed that the most packaging of CFL often lack the information of Color Rendering Index. Also, there was no correlation between
price and performance of the CFLs was indicated in this work. The results of this paper might help consumers to make more informed
CFL-purchasing decisions.
Abstract: Heart-s electric field can be measured anywhere on
the surface of the body (ECG). When individuals touch, one person-s
ECG signal can be registered in other person-s EEG and elsewhere
on his body. Now, the aim of this study was to test the hypothesis
that physical contact (hand-holding) of two persons changes their
heart rate variability. Subjects were sixteen healthy female (age: 20-
26) which divided into eight sets. In each sets, we had two friends
that they passed intimacy test of J.sternberg. ECG of two subjects
(each set) acquired for 5 minutes before hand-holding (as control
group) and 5 minutes during they held their hands (as experimental
group). Then heart rate variability signals were extracted from
subjects' ECG and analyzed in linear feature space (time and
frequency domain) and nonlinear feature space. Considering the
results, we conclude that physical contact (hand-holding of two
friends) increases parasympathetic activity, as indicate by increase
SD1, SD1/SD2, HF and MF power (p
Abstract: Consumer electronics are pervasive. It is impossible to
imagine a household or office without DVD players, digital cameras,
printers, mobile phones, shavers, electrical toothbrushes, etc. All
these devices operate at different voltage levels ranging from 1.8 to
20 VDC, in the absence of universal standards. The voltages
available are however usually 120/230 VAC at 50/60 Hz. This
situation makes an individual electrical energy conversion system
necessary for each device. Such converters usually involve several
conversion stages and often operate with excessive losses and poor
reliability. The aim of the project presented in this paper is to design
and implement a multi-channel DC/DC converter system,
customizing the output voltage and current ratings according to the
requirements of the load. Distributed, multi-agent techniques will be
applied for the control of the DC/DC converters.
Abstract: We evaluated the effect of sensory (direct current
(DC), 600μA) and motor (monophasic current, pulse duration 300μs,
100 Hz, 2.5-3mA) intensities of cathodal electrical stimulation (ES)
current to release VEGF and biomechanical properties of wound. 54
male Sprague-dawley rats were randomly assigned into one control
and two experimental groups. A full thickness skin incision was
made on animals- dorsal region. The experimental groups received
ES for 1h/day and every other day. VEGF expression was measured
in skin on the 7th day after surgical incision and tensile strength was
measured on 21st day. On the 7th day, the values of skin VEGF in the
sensory group were significantly greater than those of the other
groups (p < 0.05). Sensory and Motor intensity stimulation, can not
improve the biomechanical properties of the repaired wounds.
It seems the mechanical environment induced by sensory and
motor intensity of electrical stimulation, could not simulate the role
of normal daily stress and strain to maturation of collagen fibers and
their cross links. Further work is needed to determine the relationship
between VEGF expression after ES and its effect on tensile strength
of healed wound.
Abstract: This paper investigates the application of large scale (LS-PV) two-axis tracking photovoltaic power plant in Al-Jagbob, Libya. A 50MW PV-grid connected (two-axis tracking) power plant design in Al-Jagbob, Libya has been carried out presently. A hetero-junction with intrinsic thin layer (HIT) type PV module has been selected and modeled. A Microsoft Excel-VBA program has been constructed to compute slope radiation, dew-point, sky temperature, and then cell temperature, maximum power output and module efficiency for this system, for tracking system. The results for energy production show that the total energy output is 128.5 GWh/year. The average module efficiency is 16.6%. The electricity generation capacity factor (CF) and solar capacity factor (SCF) were found to be 29.3% and 70.4% respectively. A 50MW two axis tracking power plant with a total energy output of 128.5 GWh/year would reduce CO2 pollution by 85,581 tonnes of each year. The payback time for the proposed LS-PV photovoltaic power plant was found to be 4 years.
Abstract: Antimosy-doped tin oxide (ATO) particles were
prepared via chemical coprecipitation and reverse emulsion. The size
and size distribution of ATO particles were obviously decreased via
reverse microemulsion method. At the relatively high yield the ATO
particles were nearly spherical in shape, meanwhile the crystalline
structure and excellent conductivity were reserved, which could satisfy
the requirement as composite fillers, such as dielectric filler of
polyimide film.
Abstract: Recently electric vehicles are becoming popular as an
alternative of conventional fossil fuel vehicles. Conventional Internal
Combustion Engine (ICE) vehicle uses fossil fuel which contributing
a major part of overall carbon emission in the environment. Carbon
and other green house gas emission are responsible for global
warming and resulting climate change. It becomes vital to evaluate
performance of vehicle based on emission. In this paper an effort has
been made to depict the picture of emission caused by vehicle and
scenario of Australia has taken into account. Effort has been made to
compare the fossil based vehicle with electric vehicle in phases. The
study also evaluates advancement in electric vehicle technology,
required infrastructure for sustainability and future scope of
developments. This paper also includes the evaluation of electric
vehicle concept for pollution control and sustainable transport
systems in future. This study can be a benchmark for development of
electric vehicle as low carbon emission alternative for the cities of
tomorrow.