Voltage Stability Assessment and Enhancement Using STATCOM - A Case Study

Recently, increased attention has been devoted to the voltage instability phenomenon in power systems. Many techniques have been proposed in the literature for evaluating and predicting voltage stability using steady state analysis methods. In this paper P-V and Q-V curves have been generated for a 57 bus Patiala Rajpura circle of India. The power-flow program is developed in MATLAB using Newton Raphson method. Using Q-V curves the weakest bus of the power system and the maximum reactive power change permissible on that bus is calculated. STATCOMs are placed on the weakest bus to improve the voltage and hence voltage stability and also the power transmission capability of the line.





References:
[1] C. Barbier and J. P. Barret, "Analysis of Phenomena of Voltage Collapse on a Transmission system,” Review Generale de lÕelectricite, vol. 89, pp. 672-690, Oct. 1980.
[2] Miller T. J. E., editor, "Reactive Power Control in Electric Systems,” John Wiley &Sons, New York, 1982.
[3] Saadat H., "Power System Analysis,” McGraw-Hill International Editions, vol 17, pp. 114-136, 2004.
[4] Taylor C. W., "Power System Voltage Stability,” McGraw-Hill Inc., New York 1994.
[5] Glover D. J. and Sarma M. S., "Power System Analysis & Design,” PWS Publishing Company, Third Edition, 2001.
[6] Machowski, Bialek and Bumby "Power System Dynamics and Stability" John Wiley & Sons Ltd, 1997.
[7] Sirisuth, Piya "Voltage Instability analysis using the Sensitivity of Minimum Singular Value of Load Flow Jacobian" 1993.
[8] Ajjarapu, V. and Lee, B. "Bibliography on Voltage Stability" IEEE Trans. on Power Systems, vol. 13, pp.115-125, 1998
[9] Van Cutsem T. and Vournas C., "Voltage Stability of Electric Power Systems,” Springer, Second Printing, 2008.
[10] Bulent Aydin, "Voltage Security Assessment Using P-V and Q-V Curves,” Master Thesis, T.C. Bahcesehir Universitesi, Istanbul, 2008.
[11] Kundur P., "Power System Stability and Control,” McGraw-Hill Inc., New York, USA, 1994.
[12] M.H.Haque, "Optimal location of shunt FACTS devices in long transmission line’, IEEE Proceedings on Generation Transmission & Distribution, Vol.147, No.4, pp.218-22, 2000.
[13] Chiang H. D., Wang C. S., and Flueck A. J., "Look-Ahead Voltage and Load Margin Contingency Selection Functions for Large-Scale Power Systems,” IEEE Transactions on Power Systems, Vol.12, No. 1, pp. 173-180, Feb. 1997.
[14] Chowdhury B. H. and Taylor C. W., "Voltage Stability Analysis: V-Q Power Flow Simulation versus Dynamic Simulation,” IEEE Transactions on Power Systems, Vol.15, No. 4, pp. 1354-1359, Nov. 2000.
[15] Bergen R., Power Systems Analysis. Prentice-Hall,New Jersey. 1986.
[16] Canizares C.A.," Conditions For Saddle-Node Bifurcations In AC/DC Power Systems,”. Int. J. of Electric Power & Energy Systems, vol. 17, no. 1 February pp.:61-68, 1995.
[17] N.G. Hingorani, EPR!, "Flexible AC Transmission System," IEEE Spectrum power systems, April 1993, pp. 40-45.
[18] A. M. Gole, V.K. Sood, "A static Compensator model for use with Electromagnetic Transients simulation Programs," IEEE Transactions on Power Delivery, vol. 5, No.3, July 1990, pp. 1398 - 1407.
[19] Cigre international conference on large high voltage Electric systems," Facts Overview", IEEE Power Engineering Society April, 1995.
[20] Dr. SA Khaparde, Mr. S.M. Brahma, "Flexible AC Transmission System (FACTS): An Overview", Transmission and Distribution in 2000 Technical Conferences February 1996. pp. 1-5.