Volume:8, Issue: 1, 2014 Page No: 14 - 19
ISSN: 2517-9934
In this research, the TRACE/PARCS model of
Lungmen ABWR has been developed for verification of ultimate
response guideline (URG) efficiency. This ultimate measure was
named as DIVing plan, abbreviated from system depressurization,
water injection and containment venting. The simulation initial
condition is 100% rated power/100% rated core flow. This research
focuses on the estimation of the time when the fuel might be damaged
with no water injection by using TRACE/PARCS first. Then, the
effect of the reactor core isolation system (RCIC), control
depressurization and ac-independent water addition system (ACIWA),
which can provide the injection with 950 gpm are also estimated for
the station blackout (SBO) transient.