Technique for Grounding System Design in Distribution Substation

This paper presents the significant factor and give some suggestion that should know before design. The main objective of this paper is guide the first step for someone who attends to design of grounding system before study in details later. The overview of grounding system can protect damage from fault such as can save a human life and power system equipment. The unsafe conditions have three cases. Case 1) maximum touch voltage exceeds the safety criteria. In this case, the conductor compression ratio of the ground gird should be first adjusted to have optimal spacing of ground grid conductors. If it still over limit, earth resistivity should be consider afterward. Case 2) maximum step voltage exceeds the safety criteria. In this case, increasing the number of ground grid conductors around the boundary can solve this problem. Case 3) both of maximum touch and step voltage exceed the safety criteria. In this case, follow the solutions explained in case 1 and case 2. Another suggestion, vary depth of ground grid until maximum step and touch voltage do not exceed the safety criteria.




References:
[1] T. Thasananutariya, K. Spuntupong, and S. Chatratana, "Design of
Grounding System for GIS Indoor Substation", in Proc. TENCON IEEE Region 10 Conf. pp. 413 - 416, 2004.
[2] IEEE Std 80-2000, "IEEE Guide for Safety in AC Substation Grounding", 2000.
[3] ANSI/IEEE Std 81-1983, "IEEE Guide for Measuring Earth Resistivity,
Ground Impedance, and Earth Surface Potentials of a Ground System",1983.
[4] A. Phayomhom, S. Sirisumranikul, T. Kasirawat and A. Puttarach,
"Safety Design Planning of Ground Grid for Outdoor Substation in MEA-s Power Distribution System", in Proc. Electrical Engineering/ Electronics Computer Telecom. and Information
Technology International Conf. pp. 298-302, 2010.
[5] P. A. Zotos, "Ground Grid Design in Large Industrial Plants", IEEE
Tran. Industry Applications, vol. 24, no. 3, pp.521-525, May/June,
1988.
[6] IEEE Std 367-1996, "IEEE Recommended Practice for Determining the
Electric Power Station Ground Potential Rise and Induced Voltage From
a Power Fault", 1996.
[7] M. Mitolo, P. E. Sutherland and R. Natarajan, "Effects of High Fault Currents on Ground Grid Design", IEEE Trans. Industry Applications,
vol. 46, no. 3,May/June, 2010
[8] A. Puttarach, N. Chakpitak, T.Kasirawat, and C. Pongsriwat,
"Substation Grounding Grid Analysis with theVariation of Soil layer
depth Method",in Proc. IEEE Lausanne, Power Tech. pp. 1881-1886,
2007.
[9] H. M. Khodr, G. A. Salloum, J. T. Saraiva, and M.A. Matos, "Design of
grounding systems in substations using a mixed-integerlinear
programming formulation", Electric Power Systems Research, Vol. 79,
pp. 126-133, 2007.
[10] A. Phayomhom, S. Sirisumrannukul, T.Kasirawat, A. Puttarach, C.
Klinsopon, and P. Pearnont, "Safety Analysis for Grounding System of
Two Neighbouring Substations: Case Study of Metropolitan
ElectricityAuthority-s System", GMSARN International Journal 5 pp.
169 - 178, 2011.
[11] Marcus O. Durham, and Robert A. Durham, "Grounding System
Designfor IsolatedLocationsand Plant Systems",in Proc. Petroleum and
chemical Industry Conf. pp. 145-153, 1995.
[12] Yanqing GAO, Rong Zeng, Xidong Liang, Jinliang HE, Weimin Sun
and Qi SU, "Safety Analysis of Grounding Grid for Substation with
Different Structure",In Proc. Power System Tech. International Conf.
pp. 1487-1492, 2000.
[13] F.Dawalibi, and D.Mukhedkar, "Optimum Designof Substation
Grounding in a Two Layer Earth StructurePart III Study of Grounding
Grids Performanceandnew Electrodes Configuration",IEEE Tran. Power
Apparatus and Systems, vol. 94, no. 2, pp. 267-282, March/April, 1975.
[14] Jinliang He, RongZeng, YanqingGao, YoupingTu, Weimin Sun, Jun
Zou,and Zhicheng Guan, "Seasonal Influences on Safety of Substation Grounding System", IEEE Tran. Power Delivery, vol. 18, no. 3, pp. 788-795, July, 2003.