Parametric Study of a Vapor Compression Refrigeration Cycle Using a Two-Phase Constant Area Ejector

There are several ways of improving the performance of a vapor compression refrigeration cycle. Use of an ejector as expansion device is one of the alternative ways. The present paper aims at evaluate the performance improvement of a vapor compression refrigeration cycle under a wide range of operating conditions. A numerical model is developed and a parametric study of important parameters such as condensation (30-50°C) and evaporation temperatures (-20-5°C), nozzle and diffuser efficiencies (0.75-0.95), subcooling and superheating degrees (0-15K) are investigated. The model verification gives a good agreement with the literature data. The simulation results revealed that condensation temperature has the highest effect (129%) on the performance improvement ratio while superheating has the lowest one (6.2%). Among ejector efficiencies, the diffuser efficiency has a significant effect on the COP of ejector expansion refrigeration cycle. The COP improvement percentage decreases from 10.9% to 4.6% as subcooling degrees increases by 15K.


Authors:



References:
<p>[1] C. Aprea, R. Mastrullo, C. Renno, &ldquo;Fuzzy control of the compressor speed in a refrigeration plant,&rdquo; International Journal of Refrigeration 2004, 27(6), pp. 639-648. [2] J. Sarkar, &ldquo;Ejector enhanced vapor compression refrigeration and heat pump systems - A review,&rdquo; Renewable and Sustainable Energy Reviews 2012, 16 (9), pp. 6647-6659. [3] A.A Kornhauser, &ldquo;The use of an ejector as a refrigerant expander,&rdquo; In: Proceedings of the USN/IIR-Purdue refrigeration conference 1990, West Lafayette, IN, USA, pp. 10&ndash;9. [4] N. Bilir, H.K Ersoy, &ldquo;Performance improvement of the vapour compression refrigeration cycle by a two-phase constant area ejector,&rdquo; International Journal of Energy Research 2009, 33(5),pp. 469&ndash;80. [5] J. Sarkar, &ldquo;Performance characteristics of natural refrigerants based ejector expansion refrigeration cycles,&rdquo; Proceedings of the IMechE, Part A: Journal of Power and Energy 2009,223, pp. 543&ndash;50. [6] J. Sarkar, &ldquo;Geometric parameter optimization of ejector-expansion refrigeration cycle with natural refrigerants,&rdquo; International Journal of Energy Research 2010,34(1), pp. 84&ndash;94. [7] E. Nehdi, L. Kairouani, M. Bouzaina, &ldquo;Performance analysis of the vapour compression cycle using ejector as an expander,&rdquo; International Journal of Energy Research 2007, 31(4), 364&ndash;75. [8] K.F Fong, C.K Lee, T.T Chow, &ldquo;Improvement of solar-electric compression refrigeration system through ejector-assisted vapour compression chiller for space conditioning in subtropical climate,&rdquo; Energy Buildings 2011,43, pp. 3383&ndash;90. [9] D. Li, E.A Groll, &ldquo;Transcritical CO2 refrigeration cycle with ejectorexpansion device,&rdquo; International Journal of Refrigeration 2005, 28, pp. 766&ndash;773. [10] J.Q Deng, P.X Jiang, T. Lu, W. Lu, &ldquo;Particular characteristics of transcritical CO2 refrigeration cycle with an ejector,&rdquo; Applied Thermal Engineering 2007, 27, pp. 381&ndash;388. [11] S.A Klein. Engineering Equation Solver (EES). F-Chart Software 2013, Madison: Wisconsin.</p>