Nonlinear Modeling and Analysis of AAC infilled Sandwich Panels for out of Plane Loads

Sandwich panels are widely used in the construction industry for their ease of assembly, light weight and efficient thermal performance. They are composed of two RC thin outer layers separated by an insulating inner layer. In this research the inner insulating layer is made of lightweight Autoclaved Aerated Concrete (AAC) blocks which has good thermal insulation properties and yet possess reasonable mechanical strength. The shear strength of the AAC infill is relied upon to replace the traditionally used insulating foam and to provide the shear capacity of the panel. A comprehensive experimental program was conducted on full scale sandwich panels subjected to bending. In this paper, detailed numerical modeling of the tested sandwich panels is reported. Nonlinear 3-D finite element modeling of the composite action of the sandwich panel is developed using ANSYS. Solid elements with different crashing and cracking capabilities and different constitutive laws were selected for the concrete and the AAC. Contact interface elements are used in this research to adequately model the shear transfer at the interface between the different layers. The numerical results showed good correlation with the experimental ones indicating the adequacy of the model in estimating the loading capacity of panels.




References:
[1] Abdel-Mooty, M., Al-Kashif, M., Fahmy, E., Abou Zeid, M., and
Haroun M. (2012). Reinforced Concrete Sandwich Panels with
Autoclaved Aerated Concrete Infill, Proceedings of the International
Conference on Innovation and Technology for Sustainable Built
Environment, April 16-17, Malaysia.
[2] Benayoune, A. et al. (2008). Flexural Behaviour of Precast Concrete
Sandwich Composite Panel - Experimental and Theoretical
Investigations, Construction and Building Materials Journal, Vol. 22, pp
580-592.
[3] Fahmy, E., Shaheen, Y., Abou Zeid, M., and Gaafar H. (2006).
Ferrocement Sandwich and Hollow Core Panels for Wall Construction,
Journal of Ferrocement, Vol. 36, No. 3, Thailand, July 2006.
[4] Salmon, D., Einea, A., Tadros, M., and Culp, T. (1994). A New
Structurally and Thermally Efficient Precast Sandwich Panel Systems,
PCI Journal, Vol. 39, No. 4, 90-101
[5] Kachlakev D.I., Miller, T., Yim, S., Chansawat, K. and Potisuk, T.
(2001). Finite Element Modeling of Reinforced Concrete Structures
Strengthened With FRP Laminates, California Polytechnic State
University, San Luis Obispo, CA
[6] Kim E. Seeber et al. (1997). State-of-the-Art Report on
Precast/Prestressed Sandwich Wall Panels- PCI Committee Report, PCI
Journal, Vol.42, No.2, pp 1-61
[7] Willam, K. and Warnke, E. (1975). Constitutive Model for the Triaxial
Behavior of Concrete. Proceedings, International Association for Bridge
and Structural Engineering, Italy. Vol. 19. p. 174.