FEA for Teeth Preparations Marginal Geometry

Knowledge of factors, which influence stress and its distribution, is of key importance to the successful production of durable restorations. One of this is the marginal geometry. The objective of this study was to evaluate, by finite element analysis (FEA), the influence of different marginal designs on the stress distribution in teeth prepared for cast metal crowns. Five margin designs were taken into consideration: shoulderless, chamfer, shoulder, sloped shoulder and shoulder with bevel. For each kind of preparation three dimensional finite element analyses were initiated. Maximal equivalent stresses were calculated and stress patterns were represented in order to compare the marginal designs. Within the limitation of this study, the shoulder and beveled shoulder margin preparations of the teeth are preferred for cast metal crowns from biomechanical point of view.




References:
[1] S. Rosenstiel, M. Land, J. Fujimoto, Contemporary fixed prosthodontics,
3rd ed. Mosby, St. Louis, 2001.
[2] P.L. Tan, D.G. Gratton, A.M. Diaz-Arnold, D.C. Holmes, "An In Vitro
Comparison of Vertical Marginal Gaps of CAD/CAM Titanium and
Conventional Cast Restorations", J Prosthodons, 2008 (17): 378-83.
[3] A.B. Olivera, T. Saito, "The Effect of Die Spacer on Retention and
Fitting of Complete Cast Crowns", J Prosthodont 2006;15:243-9.
[4] A. Bindl, W.H. Mormann, "Marginal and internal fit of all-ceramic
CAD/CAM crown-copings on chamfer preparations", J Oral Rehabil,
2005 Jun;32(6):441-7.
[5] M. F. Ayad, "Effects of Tooth Preparation Burs and Luting Cement
Types on the Marginal Fit of Extracoronal Restorations", J Prosthodont,
2009, 18:145-51.
[6] E.A. Tsitrou, R. van Noort, "Minimal preparation designs for single
posterior indirect prostheses with the use of the Cerec system", Int J
Comput Dent, 2008;11(3-4):227-40.
[7] F. Beuer, H. Aggstaller, D. Edelhoff, W. Gernet, "Effect of Preparation
Design on the Fracture Resistance of Zirconia Crown Copings", Dent
Mater J 2008; 27(3): 362´╝ì7.
[8] P. Kohorst, H. Brinkmann, J. Li, L. Borchers, M. Stiesch, "Marginal
accuracy of four-unit zirconia fixed dental prostheses fabricated using
different computer-aided design/computer-aided manufacturing
systems", Eur J Oral Sci, 2009;117(3):319-25.
[9] N. De Jager, P. Pallav, A.J. Feilzer, "The influence of design parameters
on the FEA-determined stress distribution in CAD-CAM produced allceramic
dental crowns", Dent Mater, 2005,21(3):242-51.
[10] A. Shinya, L.V. Lassila, P.K. Vallittu, A. Shinya, "Three-dimensional
finite element analysis of posterior fiber reinforced composite fixed
partial denture: framework design for pontic", Eur J Prosthodont Restor
Dent, 2009;17(2):78-84.
[11] E.A. Tsitrou, M. Helvatjoglu-Antoniades, R. van Noort, "A preliminary
evaluation of the structural integrity and fracture mode of minimally
prepared resin bonded CAD/CAM crowns", J Dent, 2010;38(1):16-22.