Difference of Properties on Surface Leakage and Discharge Currents of Porcelain Insulator Material

This paper presents the experimental results of comparison between leakage currents and discharge currents. The leakage currents were obtained on polluted porcelain insulator. Whereas, the discharge currents were obtained on lightly artificial polluted porcelain specimen. The conducted measurements were leakage current or discharge current and applied voltage. The insulator or specimen was in a hermetically sealed chamber, and the current waveforms were analyzed using FFT. The result indicated that the leakage current (LC) on low RH condition the fifth harmonic would be visible, and followed by the seventh harmonic. The insulator had capacitive property. Otherwise, on 99% relative humidity, the fifth harmonic would also be visible, and the phase angle reached up to 12.2 degree. Whereas, on discharge current, the third harmonic would be visible, and followed by fifth harmonic. The third harmonic would increase as pressure reduced. On this condition, the specimen had a non-linear characteristics




References:
[1] Boudissa, R., Djafri, S., Haddad, A. , Belaicha, R., Bearsch, R.,
Effect of Insulator Shape on Surface Discharges and Flashover under Polluted Condition, IEEE Transactions on Dielectrics and
Electrical Insulation, Vol. 12, No.3, June 2005, pp. 429-437.
[2] Huang, Q., Karady, G.G., Shi, B., Tuominen, M., Study on Development of Dry Band on ADSS Fiber Optic Cable, IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 12,
No.3, June 2005.
[3] Amarh, F., Karady, G.G., Raji Sundararajan, Linear Stochastic
Analysis of Polluted Insulator Leakage Current, IEEE
Transaction on Power Delivery , Vol. 17, No. 4, October 2002,
pp. 1063-1069.
[4] Kind, D., Karner, H., High-Voltage Insulation Technology, Friedr.
Vieweg & Sohn Verlagsgessellschaft, mbH, Braunscheweig,
1985, pp. 57-61.
[5] Obenaus. F., 1935, "Die Uberschlagspnnung verschmutzter
isolatoren", ETZ.,56, 369-370.
[6] Smaili, A., Mahi, D., Zegnini, B., Study of the Electrical
Flashover of an Insulating Surface Polluted by an Alternating
Current Discharge, www.emo.org.tr/ resimler/ ekler/
0263dbb2fb8547_ek.pdf, access on October 2008.
[7] Jolly, D.C., Chu, S.T., Surface Electrical Breakdown of Tin-
Oxide Coated Glass, Journal of Applied Physics, No. 50(10),
1979, pp. 6196-6199.
[8] Vosloo, Wallace L., supervised by Holthhausen, -A Comparison
of the Performance of High-Voltage Insulator Materials in a
Severely Polluted Coastal Environment-, PhD Dissertation,
Department of Electrical and Electronic Engineering, University
of Stellenbosch, South Africa, March 2002, pp.9-10.
[9] Vosloo, W.L., Macey, R.E., Toureil, C. de, -The Practical Guide
to Outdoor High Voltage Insulators-, Crown Publications CC.,
Johannesburg, South Africa, 2004, pp.36-37.
[10] Suwarno, ÔÇÿLeakage Current Waveforms of Outdoor Polymeric
Insulators and Possibility of Application for Diagnostics of
Insulator Conditions-, Journal of Electrical Engineering &
Technology, The Korean Institute of Electrical Engineering,
Vol.1,No.1, 2006, pp.114-119.
[11] OriginLab Co., ÔÇÿOrigin V75 User's Manual-, OriginLab
Corporation, MA,USA, 2003, pp.601-611.