A Study on Method for Identifying Capacity Factor Declination of Wind Turbines

The investigation on wind turbine degradation was
carried out using the nacelle wind data. The three Vestas V80-2MW
wind turbines of Sungsan wind farm in Jeju Island, South Korea were
selected for this work. The SCADA data of the wind farm for five
years were analyzed to draw power curve of the turbines. It is assumed
that the wind distribution is the Rayleigh distribution to calculate the
normalized capacity factor based on the drawn power curve of the
three wind turbines for each year. The result showed that the reduction
of power output from the three wind turbines occurred every year and
the normalized capacity factor decreased to 0.12%/year on average.





References:
[1] G. Hughes, "The performance of wind farms in the United Kingdom and
Denmark", Renewable Energy Foundation. pp. 48, 2012.
[2] J. Harrison, "Viability of the Algonquin power Amherst Island wind
energy generating system", Association to protect Amherst Island. 2012.
[3] International Electrotechnical Commission, IEC 61400-1, 3rd ed. wind
turbines - Part 1: Design requirements.
[4] A. Albers, H. Klug and D. Westermann, "Power performance
verification", 1999 European Wind Energy Conference, Nice, France,
pp.657-660, 1999.
[5] B. Smith, H. Link, G. Randall and T. McCoy, "Applicability of nacelle
anemometer measurements for use in turbine power performance tests",
National Renewable Energy Lab, 2002.
[6] International Electrotechnical Commission, IEC 61400-12-2, 1st ed. wind
turbines - Part 12-2: Power performance of electricity-producing wind
turbines based on nacelle anemometry.
[7] D. H. Shin, H. W. Kim and K. N. Ko, "Analysis of wind turbine
degradation using the nacelle transfer function", Journal of Mechanical
Science and Technology, submitted for publication.
[8] PF. Bach, "Capacity factor degradation for Danish wind turbines",
Paul-Frederik Bach report, 2012.
[9] International Electrotechnical Commission, IEC 61400-12-1, 1st ed. wind
turbines - Part 12-1: Power performance measurements of electricity
producing wind turbines.
[10] H. W. Kim, K. N. Ko and J. C. Huh, "Wind turbine power performance
testing using nacelle transfer function", Journal of the Korean Solar
Energy Society, 33(4), pp.51-8. 2013.
[11] A. Curvers and P.A. van der Werff, "OWEZ wind farm efficiency",
ECN-E-08-092, pp.11-13, 2009.