Volume:8, Issue: 2, 2014 Page No: 166 - 174
ISSN: 2415-6620
This study is aiming at establishing the relationship
between the optical signal of flame and an equivalent ratio of flame. In
this experiment, flame optical signal in a furnace is measured using
photodiode. The combustion system is composed of metal fiber burner
and vertical furnace, and flame chemiluminescence is measured at
various experimental conditions. In this study, the flame
chemiluminescence of laminar premixed flame is measured using
commercially available photodiode. It is experimentally investigated
the relationship between equivalent ratio and photodiode signal. In
addition, the strategy of combustion control method is proposed using
the optical signal and fuel pressure.
The results showed that certain relationship between optical data of
photodiode and equivalence ratio exists, and this leads to the
successful application of this system for instantaneous measurement of
equivalence ration of the combustion system.