An Optical Sensing Film for Fe(III) Determination Based on 1,1′- diethyl 2,2′- cyanine Iodide Immobilized in Nafion Film

An optical chemical sensing film based on immobilizing of 1,1′- diethyl 2,2′-cyanine (pseudocyanine iodide) in nafion film was developed for the determination of Fe(III). The sensing film was homogeneous, transparent, and mechanically stable. Decrease of the absorbance measured at 518 nm was observed when the sensing film was immersed in a solution of Fe(III). The optimum response of the sensing film to Fe(III) was obtained in a solution with pH 4.0. Linear calibration curve over an Fe(III) concentration range of 1-30 ppm with a limit of detection of 0.71 ppm was obtained. Cd(II) is the major interference. The sensing film exhibited good stability for 2 months and high reproducibility. The proposed method was applied for the determination of Fe(III) in water samples with satisfactory results.




References:
[1] WHO. Iron in drinking-water. Background document for preparation
of WHO guidelines for drinking-water quality. Geneva: WHO Press,
Vol. 1, 2008, pp. 390-391.
[2] H. Bag, M. Lale and A. R. Turker, "Determination of iron and nickel by
flame atomic absorption spectrophotometry after preconcentration on
saccharomycescerevisiae immobilized sepiolite," Talanta. Vol. 47,
1998, pp. 689-696.
[3] A. Asan, M. Andac and I. Isildak, "Flow injection spectrofluorimetric
determination of iron(III) in water using salicylic acid," Chemical
Papers. Vol. 64 (4), 2010, pp. 424-428.
[4] T. Makino, K. Nakamura and K. Takahara, "A high-performance liquid
immunoaffinity chromatography method for determining transferrinbound
iron in serum," Clinica Chimica Acta. Vol. 412, 2011, pp. 914-
919.
[5] O. Oter, K. Ertekin, C. Kirimis, M. Koca, and M. Ahmedzade,
"Characterization of a newly synthesized fluorescent benzofuran
derivative and usage as a selective fiber optic sensor for Fe(III),"
Sensors and Actuators B:Chemical. Vol. 122, 2007, pp. 450-456.
[6] N. Malçik, and P. Çaglar, "The operational parameter of a new fibreoptic
sensor for ferric ions in aqueous media," Sensors and Actuators B:
Chemical. Vol. 38, 1997, pp. 386-389.
[7] X. B. Zhang, G. Cheng, W. J. Zhang, G.L. Shen, and R.Q. Yu, "A
fluorescent chemical sensor for Fe(III) based on blocking of
intramolecular proton transfer of a quinazolinone derivative," Talanta.
Vol. 71, 2007, pp. 171-177.
[8] P. P. Tofi├▒o, J. M. Barrero-Moreno and M. C. Pérez-Conde, "A flowthrough
fluorescent sensor to determine Fe(III) and total inorganic iron,"
Talanta. Vol. 51, 1999, pp. 537-545.
[9] G. Ozturk, S. Alp, and K. Ertekin, "Fluorescence emission studied of 4-
(2-furylmethylene)-2-phenyl-5-oxazolone embedded in polymer thin
film and detection of Fe3+ ion," Dyes and Pigments. Vol. 72, 2007, pp.
150-156.
[10] M. Zhang, B. Zheng, H. Yuan, and D. Xiao, "A spectrofluorimetric
sensor based on grape skin tissue for determination of iron(III),"
Bulletin of the Chemical Society of Ethiopia. Vol. 24(1), 2010, pp. 31-
37.
[11] A. E. Greenberg, L. S. Clesceri, and A. D. Eaton, Standard Methods for
Examination of Water and Wastewater, 18th ed., American public health
association, Washington, 1992. pp. 328-329.