Performance and Availability Analyses of PV Generation Systems in Taiwan
The purpose of this article applies the monthly final
energy yield and failure data of 202 PV systems installed in Taiwan to
analyze the PV operational performance and system availability. This
data is collected by Industrial Technology Research Institute through
manual records. Bad data detection and failure data estimation
approaches are proposed to guarantee the quality of the received
information. The performance ratio value and system availability are
then calculated and compared with those of other countries. It is
indicated that the average performance ratio of Taiwan-s PV systems
is 0.74 and the availability is 95.7%. These results are similar with
those of Germany, Switzerland, Italy and Japan.
[1] http://www.iea-pvps-task2.org/index.htm
[2] http://solarpv.itri.org.tw/performance/demo/year.asp
[3] U. Jahn and and B. Grimming, "Analysis of Photovoltaic Systems,"
Report IEA-PVPS T2-01:2000, 2000.
[4] U. Jahn, etc., "International Energy Agency PVPS Task 2: Analysis of the
Operational Performance of the IEA Database Systems," 16th European
Photovoltaic Solar Energy Conference and Exhibition, Glasgow, United
Kingdom, May 2000
[5] R. Billinton and R. N. Allan, Reliability Evaluation of Engineering
System - Concepts and Technique, Plenum Press, Second Ed., 1992.
[6] "IEA PVPS Task2 - Performance, Reliability and Analysis of
Photovoltaic Systems," www.iea-pvps-task2.org.
[7] U. Jahn, T. Nordmann and L. Clavadetscher, "Performance of
Grud-Connected PV Systems: Overview of PVPS Task 2 Results," IEA
PVPS 2 Meeting, Florida, USA, Feb. 28- March 2, 2005.
[8] K. Otani, T. Takashima and K. Kurokawa, "Performance and Reliability
of 1 MW Photovoltaic Power Facilities in AIST, 2006 IEEE 4th World
Conference on Photovoltaic Energy Conversion, Vol. 2, pp. 2046-2049,
Waikoloa, HI, 7-12 May 2006.
[9] C. Atcitty, S. Hester, D. Greenberg, D. Osborn and D. Collier,
"Photovoltaic System Reliability," 26th PVSC, pp. 1049-1054, Anaheim,
CA, Sep. 30-Oct. 3, 1997.
[1] http://www.iea-pvps-task2.org/index.htm
[2] http://solarpv.itri.org.tw/performance/demo/year.asp
[3] U. Jahn and and B. Grimming, "Analysis of Photovoltaic Systems,"
Report IEA-PVPS T2-01:2000, 2000.
[4] U. Jahn, etc., "International Energy Agency PVPS Task 2: Analysis of the
Operational Performance of the IEA Database Systems," 16th European
Photovoltaic Solar Energy Conference and Exhibition, Glasgow, United
Kingdom, May 2000
[5] R. Billinton and R. N. Allan, Reliability Evaluation of Engineering
System - Concepts and Technique, Plenum Press, Second Ed., 1992.
[6] "IEA PVPS Task2 - Performance, Reliability and Analysis of
Photovoltaic Systems," www.iea-pvps-task2.org.
[7] U. Jahn, T. Nordmann and L. Clavadetscher, "Performance of
Grud-Connected PV Systems: Overview of PVPS Task 2 Results," IEA
PVPS 2 Meeting, Florida, USA, Feb. 28- March 2, 2005.
[8] K. Otani, T. Takashima and K. Kurokawa, "Performance and Reliability
of 1 MW Photovoltaic Power Facilities in AIST, 2006 IEEE 4th World
Conference on Photovoltaic Energy Conversion, Vol. 2, pp. 2046-2049,
Waikoloa, HI, 7-12 May 2006.
[9] C. Atcitty, S. Hester, D. Greenberg, D. Osborn and D. Collier,
"Photovoltaic System Reliability," 26th PVSC, pp. 1049-1054, Anaheim,
CA, Sep. 30-Oct. 3, 1997.
@article{"International Journal of Electrical, Electronic and Communication Sciences:56085", author = "H. S. Huang and J. C. Jao and K. L. Yen and C. T. Tsai", title = "Performance and Availability Analyses of PV Generation Systems in Taiwan", abstract = "The purpose of this article applies the monthly final
energy yield and failure data of 202 PV systems installed in Taiwan to
analyze the PV operational performance and system availability. This
data is collected by Industrial Technology Research Institute through
manual records. Bad data detection and failure data estimation
approaches are proposed to guarantee the quality of the received
information. The performance ratio value and system availability are
then calculated and compared with those of other countries. It is
indicated that the average performance ratio of Taiwan-s PV systems
is 0.74 and the availability is 95.7%. These results are similar with
those of Germany, Switzerland, Italy and Japan.", keywords = "availability, performance ratio, PV system, Taiwan", volume = "5", number = "6", pages = "751-5", }