Mathematical Modelling of Venturi Scrubber for Ammonia Absorption
In this study, the dispersed model is used to predict
gas phase concentration, liquid drop concentration. The venturi
scrubber efficiency is calculated by gas phase concentration. The
modified model has been validated with available experimental data
of Johnstone, Field and Tasler for a range of throat gas velocities,
liquid to gas ratios and particle diameters and is used to study the
effect of some design parameters on collection efficiency.
[1] H.F. Johnstone, R.B. Feild, M.C. Tassler, Ind. Eng. Chem. 46
(8) (1954) 1601.
[2] M.D. Kuznetsov, V.I. Oratovskii, Int. Chem. Eng. 2 (2) (1962)
85.
[3] Kh. Boyadzhiev, Int. Chem. Eng. 4 (1) (1964) 22.
[4] D. Elenkov, Kh. Boyadzhiev, Int. Chem. Eng. 7 (2) (1967) 191.
[5] B.P. Volgin, T.F. Efimova, M.S. Gofman, Int. Chem. Eng. 8 (1)
(1968) 113.
[6] S. Uchida, C.Y. Wen, Ind. Eng. Chem. Process Des. Dev. 12 (4)
(1973) 437.
[7] Fathikalajahi . J , Taheri . M , Talaie . M . R , (1996) , "
Theoretical study of non uniform droplet concentration
distribution on venturi scrubber performance " , Part . Sci . Tech
, Vol . 14 , page 153
[1] H.F. Johnstone, R.B. Feild, M.C. Tassler, Ind. Eng. Chem. 46
(8) (1954) 1601.
[2] M.D. Kuznetsov, V.I. Oratovskii, Int. Chem. Eng. 2 (2) (1962)
85.
[3] Kh. Boyadzhiev, Int. Chem. Eng. 4 (1) (1964) 22.
[4] D. Elenkov, Kh. Boyadzhiev, Int. Chem. Eng. 7 (2) (1967) 191.
[5] B.P. Volgin, T.F. Efimova, M.S. Gofman, Int. Chem. Eng. 8 (1)
(1968) 113.
[6] S. Uchida, C.Y. Wen, Ind. Eng. Chem. Process Des. Dev. 12 (4)
(1973) 437.
[7] Fathikalajahi . J , Taheri . M , Talaie . M . R , (1996) , "
Theoretical study of non uniform droplet concentration
distribution on venturi scrubber performance " , Part . Sci . Tech
, Vol . 14 , page 153
@article{"International Journal of Chemical, Materials and Biomolecular Sciences:53477", author = "S.Mousavian and D.Ashouri and M.abdolahi and M.H.Vakili and Y.Rahnama", title = "Mathematical Modelling of Venturi Scrubber for Ammonia Absorption", abstract = "In this study, the dispersed model is used to predict
gas phase concentration, liquid drop concentration. The venturi
scrubber efficiency is calculated by gas phase concentration. The
modified model has been validated with available experimental data
of Johnstone, Field and Tasler for a range of throat gas velocities,
liquid to gas ratios and particle diameters and is used to study the
effect of some design parameters on collection efficiency.", keywords = "Ammonia, Modelling, Purge gas, Removal
efficiency, Venturi scrubber", volume = "6", number = "1", pages = "56-3", }