Horizontal and Vertical Illuminance Correlations in a Case Study for Shaded South Facing Surfaces

Daylight utilization is a key factor in achieving visual and thermal comfort, and energy savings in integrated building design. However, lack of measured data related to this topic has become a major challenge with the increasing need for integrating lighting concepts and simulations in the early stages of design procedures. The current paper deals with the values of daylight illuminance on horizontal and south facing vertical surfaces; the data are estimated using IESNA model and measured values of the horizontal and vertical illuminance, and a regression model with an acceptable linear correlation is obtained. The resultant illuminance frequency curves are useful for estimating daylight availability on south facing surfaces in Tehran. In addition, the relationship between indirect vertical illuminance and the corresponding global horizontal illuminance is analyzed. A simple parametric equation is proposed in order to predict the vertical illumination on a shaded south facing surface. The equation correlates the ratio between the vertical and horizontal illuminance to the solar altitude and is used with another relationship for prediction of the vertical illuminance. Both equations show good agreement, which allows for calculation of indirect vertical illuminance on a south facing surface at any time throughout the year.





References:
[1] S. Janjai, R. Wattan, M. Nunez, A statistical approach for estimating diffuse illuminance on vertical surfaces. Build. Environ. 2009, Vol. 44, pp. 2097–2105.
[2] S. Chirarattananon, P. Rukkwansuk, P. Chaiwiwatworakul, P. Pakdeepol, Evaluation of vertical illuminance and irradiance models against data from North Bankok. Build. Environ. 2007, 42(11), pp. 3894–3904.
[3] L. Robledo, and A. Soler, Dependence on surface orientation of coefficients in the circumsolar simplified Perez illuminance model for vertical planes at Madrid. 1998, Energ. Convers. Manag. Vol. 39(15), pp. 1585–1595.
[4] E. Rezaian, K. Amini, S. Matoor, S. A. Milani, R. Fayaz, Design and geometrical optimization of the veranda roof pattern with the target of visual comfort in Shāremān as one of the Solar Decathlon China 2013 houses. 2015, Build. Simul.: Intl. J. Vol. 8, pp. 323-336.
[5] G. H. Lim, M. Hirning, N. Keumalaa, N. Ab. Ghafar, Daylight performance and users’ visual appraisal for green building offices in Malaysia. Energy and Buildings, 2017, Vol. 141, pp. 175–185.
[6] L. Komar, M. Kocifaj, Uncertainty of daylight illuminance on vertical building facades when determined from sky scanner data: A numerical study, Solar Energy, 2014, Vol. 110, pp. 15–21.
[7] S. Chirarattananon, P. Chaiwiwatworakul, and S. Pattanasethanon, Daylight availability and models for global and diffuse horizontal illuminance and irradiance for Bangkok. Renew. Energ. Vol. 26, 2002, pp. 69-89.
[8] M. Navvab, E. Karayel, Neeman., S. Selkowitz, Daylight availability data for San Francisco. Energ. build. 1984, Vol. 6, pp. 273-281.
[9] H. J. Kong, J. T. Kim, Evaluation of global vertical illuminance and irradiance models against data from Yongin, South Korea. Energy and Buildings, 2015, Vol. 91, pp. 139–147.
[10] K. Alshaibani, Potentiality of daylighting in a maritime desert climate: The Eastern coast of Saudi Arabia. Renew. Energ. 2001, Vol. 23, pp. 321-325.
[11] S. Mark, Lighting handbook reference and application. Illuminating Engineering Society of North America (IESNA). 2002, New York.
[12] S. Shekari, R. Golmohammadi, H. Mahjub, I. Mohammadfam, M. Motamedzadeh, Estimation of illuminance on the South facing surfaces for clear skies in Iran. J. Res. Health Sci. 2008, Vol. 8, pp. 46-55.
[13] D. H. W. Li, J. C. Lam, C. C. S. Lau, A new approach for predicting vertical global solar irradiance. Renew. Energ. 2002, Vol. 25, pp. 591–606.
[14] M. Tahbaz, and Sh. Jalilian. Architectural design principal compatible with climatic conditions of Iran. 2008, Tehran. Shahid Beheshti University pub.
[15] A. Pe´rez-Burgos, A. de Miguel, J. Bilbao, Daylight illuminance on horizontal and vertical surfaces for clear skies. Case study of shaded surfaces. 2010, Sol. Energ. Vol. 84, pp. 137-143.