Constitutive Equations for Human Saphenous Vein Coronary Artery Bypass Graft

Coronary artery bypass grafts (CABG) are widely studied with respect to hemodynamic conditions which play important role in presence of a restenosis. However, papers which concern with constitutive modeling of CABG are lacking in the literature. The purpose of this study is to find a constitutive model for CABG tissue. A sample of the CABG obtained within an autopsy underwent an inflation–extension test. Displacements were recoredered by CCD cameras and subsequently evaluated by digital image correlation. Pressure – radius and axial force – elongation data were used to fit material model. The tissue was modeled as onelayered composite reinforced by two families of helical fibers. The material is assumed to be locally orthotropic, nonlinear, incompressible and hyperelastic. Material parameters are estimated for two strain energy functions (SEF). The first is classical exponential. The second SEF is logarithmic which allows interpretation by means of limiting (finite) strain extensibility. Presented material parameters are estimated by optimization based on radial and axial equilibrium equation in a thick-walled tube. Both material models fit experimental data successfully. The exponential model fits significantly better relationship between axial force and axial strain than logarithmic one.




References:
[1] R. L. Leask, J. Butany, K. W. Johnston, C. R. Ethier, M. Ojha, "Human
saphenous vein coronary artery bypass graft morphology, geometry and
hemodynamics," Ann. Biomed. Eng., vol. 33, no. 3, pp. 301-309, March
2005.
[2] R. Tran-Son-Tay, et al., "An experiment-based model of vein graft
remodeling induced by shear stress," Ann. Biomed. Eng., vol. 36, no. 7,
pp. 1083-1091, July 2008.
[3] C. M. Fernandez, et al., "Impact of shear stress on early vein graft
remodeling: A biomechanical analysis," Ann. Biomed. Eng., vol. 32, no.
11, pp. 1484-1493, November 2004.
[4] F. Cacho, M. Doblaré and G. A. Holzapfel, ÔÇ×A procedure to simulate
coronary artery bypass graft surgery," Med. Bio. Eng. Cmput., vol. 45,
pp. 819-827, August 2007.
[5] C. Herbst, K. Splitthof, "Q-400 Basics of 3D digital image
correlation," [online]. Available on
http://www.dantecdynamics.com/Default.aspx?ID=855.
[6] D. Zhang, C. D. Eggleton and D. D. Arola, "Evaluationg the mechanical
behavior of arterial tissue using digital image correlation," Exp. Mech.,
vol. 42, no. 4, pp. 409 - 416, December 2002.
[7] G. A. Holzapfel, T. C. Gasser, and R. W. Ogden, "A new constitutive
framework for arterial wall mechanics and a comparative study of
material models," J. Elast., vol. 61, no. 1-3, pp. 1-48, July 2000.
[8] J. Stalhand, "Determination of human arterial wall parameters from
clinical data," Biomechan. Model. Mechanobiol., (Accepted for
publication).
[9] G. A. Holzapfel, G. Sommer, C. T. Gasser and P. Regitnig,
"Determination of layer-specific mechanical properties of human
coronary arteries with nonatherosclerotic intimal thickening and related
constitutive modeling," Am. J. Physiol. Heart Circ. Physiol., vol. 289,
no. 5, pp. H2048-H2058, November 2005.
[10] C. O. Horgan, and G. Saccomandi, "A description of arterial wall
mechanics using limiting chain extensibility constitutive models,"
Biomechan. Model. Mechanobiol., vol. 1, no. 4, pp. 251-266, Aprile
2003.
[11] C. O. Horgan, and G. Saccomandi, "A new constitutive theory for fiber-
reinforced incompressible nonlinear elastic solids," J. Mech. Phys.
Solids, vol. 53, no. 9, pp. 1985-2015, September 2005.
[12] A. N. Gent, "New constitutive relation for rubber," Rub. Chem.
Technol., vol. 69, no. 1, pp. 59-61, Mach-April 1996.
[13] L. Horny, R. Zitny, and H. Chlup, "Strain energy function for arterial
walls based on limiting fiber extensibility," Proceedings of 4th European
Congress for Medical and Biomedical Engineering 2008, 23-27 Nov
2008 Antwerp, Belgium, IFBME (Accepted for publication).
[14] G. A. Holzapfel, Nonlinear solid mechanics - A continuum approach for
engineering. Chichester: John Wiley & Sons, 2000, ch. 6.