Characterization and Development of Anthropomorphic Phantoms Liver for Use in Nuclear Medicine

The objective this study was to characterize and develop anthropomorphic liver phantoms in tomography hepatic procedures for quality control and improvement professionals in nuclear medicine. For the conformation of the anthropomorphic phantom was used in plaster and acrylic. We constructed three phantoms representing processes with liver cirrhosis. The phantoms were filled with 99mTc diluted with water to obtain the scintigraphic images. Tomography images were analyzed anterior and posterior phantom representing a body with a greater degree cirrhotic. It was noted that the phantoms allow the acquisition of images similar to real liver with cirrhosis. Simulations of hemangiomas may contribute to continued professional education of nuclear medicine, on the question of image acquisition, allowing of the study parameters such of the matrix, energy window and count statistics.




References:
[1] Sharp, P.F., Gemmell, H.G., Murray, A.D. Pratical nuclear
medicine. 3a Ed. New York: Springer, 2005.
[2] Rocha, A. F. G. Medicina nuclear. Rio de Janeiro: Guanabara
Koogan, 1976.
[3] Leslie, W.D., Greenberg, I.D. Nuclear medicine. Texas: Landes
Bioscience, 2003.
[4] Thrall, J.H., Ziessman, H.A. Medicina nuclear. 2a Ed. Rio de
janeiro: Guanabara Koogan, 2003.
[5] Gonçalves, A.R., Silva Neto, D.R., Neisser, M.P., Rode, S.M.
Avaliação da dureza e resistência ao impacto da resina acrílica para
esclera de pr├│tese ocular. Rev Fac Odontol S├úo José dos Campos,
Vol. 4 N├║mero 3, 2001, pp 29-34.
[6] Tenji, M, Conssni, R.L.X., Mesquite, M.F., Merchese, M.P. Efeito
do tempo pós-prensagem na dureza de superfície e resistência ao
impacto de resinas acrílicas. Rev Fac Odontol Passo Fundo, Vol. 9
N├║mero 1, 2004, pp 103-8.
[7] Van Meerbeek, B. G. Willems, JP Celis, J R Roos, M. Braem, P.
Lambrechts Assessment by nano-indentation of the hardness and
elasticity of the resin-dentin bonding area. J. Dent. Res., Vol. 72,
N├║mero 10, 1993, pp.1434-42.
[8] ICRU - INTERNATIONAL COMISSION ON RADIATION
UNITS AND MEASUREMENTS. Phantoms and computational
models in therapy, diagnosis and protection. ICRU REPORT 48,
1992.
[9] Biersack, H-J; Freeman, L. M. Clinical nuclear medicine. New
York: Springer, 2007
[10] Ferreira, F.C.L, Souza, D.N. Liver phantom for quality control and
training in nuclear medicine. Nuclear Instruments & Methods in
Physics Research. Section A, Accelerators, Spectrometers,
Detectors and Associated Equipment. Vol. 10, 2010, pp. 02127-3.
[11] Castro Junior, A., Rossi, G., Dimenstein, R. Guia prático em
medicina nuclear: A instrumentação. 2a Ed. São Paulo: Senac-SP,
2004.