Abstract: The previous study of new metal gasket that contact
width and contact stress an important design parameter for optimizing
metal gasket performance. The optimum design based on an elastic
and plastic contact stress was founded. However, the influence of
flange surface roughness had not been investigated thoroughly. The
flange has many kinds of surface roughness. In this study, we
conducted a gasket model include a flange surface roughness effect. A
finite element method was employed to develop simulation solution. A
uniform quadratic mesh used for meshing the gasket material and a
gradually quadrilateral mesh used for meshing the flange. The gasket
model was simulated by using two simulation stages which is forming
and tightening simulation. A simulation result shows that a smoother
of surface roughness has higher slope for force per unit length. This
mean a squeezed against between flange and gasket will be strong. The
slope of force per unit length for gasket 400-MPa mode was higher
than the gasket 0-MPa mode.
Abstract: Intelligent technologies are increasingly facilitating
sustainable water management strategies in Australia. While this
innovation can present clear cost benefits to utilities through
immediate leak detection and deference of capital costs, the impact of
this technology on households is less distinct. By offering real-time
engagement and detailed end-use consumption breakdowns, there is
significant potential for demand reduction as a behavioural response
to increased information. Despite this potential, passive
implementation without well-planned residential engagement
strategies is likely to result in a lost opportunity. This paper begins
this research process by exploring the effect of smart water meters
through the lens of three behaviour change theories. The Theory of
Planned Behaviour (TPB), Belief Revision theory (BR) and Practice
Theory emphasise different variables that can potentially influence
and predict household water engagements. In acknowledging the
strengths of each theory, the nuances and complexity of household
water engagement can be recognised which can contribute to
effective planning for residential smart meter engagement strategies.
Abstract: This paper presents the experimental results of
comparison between leakage currents and discharge currents. The leakage currents were obtained on polluted porcelain insulator.
Whereas, the discharge currents were obtained on lightly artificial
polluted porcelain specimen. The conducted measurements were
leakage current or discharge current and applied voltage. The insulator or specimen was in a hermetically sealed chamber, and the
current waveforms were analyzed using FFT.
The result indicated that the leakage current (LC) on low RH condition the fifth harmonic would be visible, and followed by the
seventh harmonic. The insulator had capacitive property. Otherwise,
on 99% relative humidity, the fifth harmonic would also be visible,
and the phase angle reached up to 12.2 degree. Whereas, on discharge current, the third harmonic would be visible, and followed
by fifth harmonic. The third harmonic would increase as pressure reduced. On this condition, the specimen had a non-linear characteristics
Abstract: This paper presents the experimental results of silicone rubber housing material for 24kV lightning arrester under artificial accelerated ageing test based on IEC 61109 specifications. Specimens having inclined and alternated shed made of HTV silicone rubber with ATH content and having leakage distance 625 mm were tested continuously 1000 hrs in artificial salt fog chamber. After 1000 hrs of salt fog ageing test, obviously surface erosion was observed on trunk between the upper large shed and the lower small shed near the energized end. Decreasing in hydrophobicity and increasing in hardness were measured on tested specimen comparing with new specimen. Chemical analysis by ATR-FTIR confirmed the observation results.
Abstract: In this paper, for the first time, a two-dimensional
(2D) analytical drain current model for sub-100 nm multi-layered
gate material engineered trapezoidal recessed channel (MLGMETRC)
MOSFET: a novel design is presented and investigated using
ATLAS and DEVEDIT device simulators, to mitigate the large gate
leakages and increased standby power consumption that arise due to
continued scaling of SiO2-based gate dielectrics. The twodimensional
(2D) analytical model based on solution of Poisson-s
equation in cylindrical coordinates, utilizing the cylindrical
approximation, has been developed which evaluate the surface
potential, electric field, drain current, switching metric: ION/IOFF
ratio and transconductance for the proposed design. A good
agreement between the model predictions and device simulation
results is obtained, verifying the accuracy of the proposed analytical
model.
Abstract: Due to their high power-to-weight ratio and low cost,
pneumatic actuators are attractive for robotics and automation
applications; however, achieving fast and accurate control of their
position have been known as a complex control problem. A
methodology for obtaining high position accuracy with a linear
pneumatic actuator is presented. During experimentation with a
number of PID classical control approaches over many operations of
the pneumatic system, the need for frequent manual re-tuning of the
controller could not be eliminated. The reason for this problem is
thermal and energy losses inside the cylinder body due to the
complex friction forces developed by the piston displacements.
Although PD controllers performed very well over short periods, it
was necessary in our research project to introduce some form of
automatic gain-scheduling to achieve good long-term performance.
We chose a fuzzy logic system to do this, which proved to be an
easily designed and robust approach. Since the PD approach showed
very good behaviour in terms of position accuracy and settling time,
it was incorporated into a modified form of the 1st order Tagaki-
Sugeno fuzzy method to build an overall controller. This fuzzy gainscheduler
uses an input variable which automatically changes the PD
gain values of the controller according to the frequency of repeated
system operations. Performance of the new controller was
significantly improved and the need for manual re-tuning was
eliminated without a decrease in performance. The performance of
the controller operating with the above method is going to be tested
through a high-speed web network (GRID) for research purposes.
Abstract: This paper presents the simulation results of electric field and potential distributions along surface of silicone rubber polymer insulators under clean and various contamination conditions with/without water droplets. Straight sheds insulator having leakage distance 290 mm was used in this study. Two type of contaminants, playwood dust and cement dust, have been studied the effect of contamination on the insulator surface. The objective of this work is to comparison the effect of contamination on potential and electric field distributions along the insulator surface when water droplets exist on the insulator surface. Finite element method (FEM) is adopted for this work. The simulation results show that contaminations have no effect on potential distribution along the insulator surface while electric field distributions are obviously depended on contamination conditions.
Abstract: In this paper, multilayered coreless printed circuit
board (PCB) step-down power transformers for DC-DC converter
applications have been designed, manufactured and evaluated. A set
of two different circular spiral step-down transformers were
fabricated in the four layered PCB. These transformers have been
modelled with the assistance of high frequency equivalent circuit and
characterized with both sinusoidal and square wave excitation. This
paper provides the comparative results of these two different
transformers in terms of their resistances, self, leakage, mutual
inductances, coupling coefficient and also their energy efficiencies.
The operating regions for optimal performance of these transformers
for power transfer applications are determined. These transformers
were tested for the output power levels of about 30 Watts within the
input voltage range of 12-50 Vrms. The energy efficiency for these
step down transformers is observed to be in the range of 90%-97% in
MHz frequency region.
Abstract: This paper presents the experimental results of
leakage current waveforms which appears on porcelain insulator
surface due to existence of artificial pollutants. The tests have been
done using the chemical compounds of NaCl, Na2SiO3, H2SO4, CaO,
Na2SO4, KCl, Al2SO4, MgSO4, FeCl3, and TiO2. The insulator
surface was coated with those compounds and dried. Then, it was
tested in the chamber where the high voltage was applied. Using
correspondence analysis, the result indicated that the fundamental
harmonic of leakage current was very close to the applied voltage
and third harmonic leakage current was close to the yielded leakage
current amplitude. The first harmonic power was correlated to first
harmonic amplitude of leakage current, and third harmonic power
was close to third harmonic one. The chemical compounds of H2SO4
and Na2SiO3 affected to the power factor of around 70%. Both are the
most conductive, due to the power factor drastically increase among
the chemical compounds.
Abstract: Acoustic Imaging based sound localization using microphone
array is a challenging task in digital-signal processing.
Discrete Fourier transform (DFT) based near-field acoustical holography
(NAH) is an important acoustical technique for sound source
localization and provide an efficient solution to the ill-posed problem.
However, in practice, due to the usage of small curtailed aperture
and its consequence of significant spectral leakage, the DFT could
not reconstruct the active-region-of-sound (AROS) effectively, especially
near the edges of aperture. In this paper, we emphasize the
fundamental problems of DFT-based NAH, provide a solution to
spectral leakage effect by the extrapolation based on linear predictive
coding and 2D Tukey windowing. This approach has been tested to
localize the single and multi-point sound sources. We observe that
incorporating extrapolation technique increases the spatial resolution,
localization accuracy and reduces spectral leakage when small curtail
aperture with a lower number of sensors accounts.
Abstract: This paper presents the experimental results of silicone rubber polymer insulators for 22 kV systems under salt water dip wheel test based on IEC 62217. Straight shed silicone rubber polymer insulators having leakage distance 685 mm were tested continuously 30,000 cycles. One test cycle includes 4 positions, energized, de-energized, salt water dip and deenergized, respectively. For one test cycle, each test specimen remains stationary for about 40 second in each position and takes 8 second for rotate to next position. By visual observation, sever surface erosion was observed on the trunk near the energized end of tested specimen. Puncture was observed on the upper shed near the energized end. In addition, decreasing in hydrophobicity and increasing in hardness were measured on tested specimen comparing with new specimen. Furthermore, chemical analysis by ATR-FTIR was conducted in order to elucidate the chemical change of tested specimens comparing with new specimen.
Abstract: The cost of damage to the non-structural systems in
critical facilities like nuclear power plants and hospitals can exceed
80% of the total cost of damage during an earthquake. The failure of
nonstructural components, especially, piping systems led to leakage of
water and subsequent shut-down of hospitals immediately after the
event. Consequently, the evaluation of performance of these types of
structural configurations has become necessary to mitigate the risk and
to achieve reliable designs.
This paper focuses on a methodology to evaluate the static and
dynamic characteristics of complex actual piping system based on
NFPA-13 and SMACNA guidelines. The result of this study revealed
that current piping system subjected to design lateral force and design
spectrum based on UBC-97 was failed in both cases and mode shapes
between piping system and building structure were very different
Abstract: Significant changes in oil and gas drilling have
emphasized the need to verify the integrity and reliability of drill
stem components. Defects are inevitable in cast components,
regardless of application; but if these defects go undetected, any
severe defect could cause down-hole failure.
One such defect is shrinkage porosity. Castings with lower level
shrinkage porosity (CB levels 1 and 2) have scattered pores and do
not occupy large volumes; so pressure testing and helium leak testing
(HLT) are sufficient for qualifying the castings. However, castings
with shrinkage porosity of CB level 3 and higher, behave erratically
under pressure testing and HLT making these techniques insufficient
for evaluating the castings- integrity.
This paper presents a case study to highlight how the radiography
technique is much more effective than pressure testing and HLT.
Abstract: Optical burst switching (OBS) has been proposed to
realize the next generation Internet based on the wavelength division
multiplexing (WDM) network technologies. In the OBS, the burst
contention is one of the major problems. The deflection routing has
been designed for resolving the problem. However, the deflection
routing becomes difficult to prevent from the burst contentions as the
network load becomes high. In this paper, we introduce a flow rate
control methods to reduce burst contentions. We propose new flow
rate control methods based on the leaky bucket algorithm and
deflection routing, i.e. separate leaky bucket deflection method, and
dynamic leaky bucket deflection method. In proposed methods, edge
nodes which generate data bursts carry out the flow rate control
protocols. In order to verify the effectiveness of the flow rate control in
OBS networks, we show that the proposed methods improve the
network utilization and reduce the burst loss probability through
computer simulations.
Abstract: As the disfunctions of the information society and
social development progress, intrusion problems such as malicious
replies, spam mail, private information leakage, phishing, and
pharming, and side effects such as the spread of unwholesome
information and privacy invasion are becoming serious social
problems. Illegal access to information is also becoming a problem as
the exchange and sharing of information increases on the basis of the
extension of the communication network. On the other hand, as the
communication network has been constructed as an international,
global system, the legal response against invasion and cyber-attack
from abroad is facing its limit. In addition, in an environment where
the important infrastructures are managed and controlled on the basis
of the information communication network, such problems pose a
threat to national security. Countermeasures to such threats are
developed and implemented on a yearly basis to protect the major
infrastructures of information communication. As a part of such
measures, we have developed a methodology for assessing the
information protection level which can be used to establish the
quantitative object setting method required for the improvement of the
information protection level.
Abstract: Privacy issues commonly discussed among
researchers, practitioners, and end-users in pervasive healthcare.
Pervasive healthcare systems are applications that can support
patient-s need anytime and anywhere. However, pervasive healthcare
raises privacy concerns since it can lead to situations where patients
may not be aware that their private information is being shared and
becomes vulnerable to threat. We have systematically analyzed the
privacy issues and present a summary in tabular form to show the
relationship among the issues. The six issues identified are medical
information misuse, prescription leakage, medical information
eavesdropping, social implications for the patient, patient difficulties
in managing privacy settings, and lack of support in designing
privacy-sensitive applications. We narrow down the issues and chose
to focus on the issue of 'lack of support in designing privacysensitive
applications' by proposing a privacy-sensitive architecture
specifically designed for pervasive healthcare monitoring systems.
Abstract: In this paper, gate leakage current has been mitigated
by the use of novel nanoscale MOSFET with Source/Drain-to-Gate
Non-overlapped and high-k spacer structure for the first time. A
compact analytical model has been developed to study the gate
leakage behaviour of proposed MOSFET structure. The result
obtained has found good agreement with the Sentaurus Simulation.
Fringing gate electric field through the dielectric spacer induces
inversion layer in the non-overlap region to act as extended S/D
region. It is found that optimal Source/Drain-to-Gate Non-overlapped
and high-k spacer structure has reduced the gate leakage current to
great extent as compared to those of an overlapped structure. Further,
the proposed structure had improved off current, subthreshold slope
and DIBL characteristic. It is concluded that this structure solves the
problem of high leakage current without introducing the extra series
resistance.
Abstract: Optical burst switching(OBS) is considered as one of
preferable network technologies for the next generation Internet. The
Internet has two traffic classes, i.e. real-time bursts and reliable bursts.
It is an important subject for OBS to achieve cooperated operation of
real-time bursts and reliable bursts. In this paper, we proposes a new
effective traffic control method named Separate TB+LB (Token
Bucket + Leaky Bucket : TB+LB) method. The proposed method
presents a new Token Bucket scheme for real-time bursts called as
RBO-TB (Real-time Bursts Oriented Token Bucket). The method also
applies the LB method to reliable bursts for obtaining better
performance. This paper verifies the effectiveness of the Separate
TB+LB method through the performance evaluation.
Abstract:
Innovation is becoming more and more important in
modern society. There are a lot of researches on different kinds of
innovation but marketing innovation is one kind of innovation that
has not been studied frequently before. Marketing innovation is
defined as a new way in which companies can market themselves to
potential or existing customers.
The study shows some key elements for marketing innovation that
are worth paying attention to when implementing marketing
innovation projects. Examples of such key elements are: paying
attention to the neglected market, suitable market segmentatio
reliable market information, public relationship, increased customer
value, combination of market factors, explore different marketing
channels and the use of technology in combination with what? Beside
the key elements for marketing innovation, we also present some
risks that may occur, such as cost, market uncertainty, information
leakage, imitation and overdependence on experience.
By proposing a set of indicators to measure marketing innovation,
the article offers solutions for marketing innovation implementation
so that any organization can achieve optimal results.
Abstract: In this paper we investigate the electrical
characteristics of a new structure of gate all around strained silicon
nanowire field effect transistors (FETs) with dual dielectrics by
changing the radius (RSiGe) of silicon-germanium (SiGe) wire and
gate dielectric. Indeed the effect of high-κ dielectric on Field Induced
Barrier Lowering (FIBL) has been studied. Due to the higher electron
mobility in tensile strained silicon, the n-type FETs with strained
silicon channel have better drain current compare with the pure Si
one. In this structure gate dielectric divided in two parts, we have
used high-κ dielectric near the source and low-κ dielectric near the
drain to reduce the short channel effects. By this structure short
channel effects such as FIBL will be reduced indeed by increasing
the RSiGe, ID-VD characteristics will be improved. The leakage
current and transfer characteristics, the threshold-voltage (Vt), the
drain induced barrier height lowering (DIBL), are estimated with
respect to, gate bias (VG), RSiGe and different gate dielectrics. For
short channel effects, such as DIBL, gate all around strained silicon
nanowire FET have similar characteristics with the pure Si one while
dual dielectrics can improve short channel effects in this structure.