Abstract: Passive control methods can be utilized to build
earthquake resistant structures, and also to strengthen the vulnerable
ones. In this paper, we studied the effect of this system in increasing
the ductility and energy dissipation and also modeled the behavior of
this type of eccentric bracing, and compared the hysteresis diagram
of the modeled samples with the laboratory samples. We studied
several samples of frames with vertical shear-links in order to assess
the behavior of this type of eccentric bracing. Each of these samples
was modeled in finite element software ANSYS 9.0, and was
analyzed under the static cyclic loading. It was found that vertical
shear-links have a more stable hysteresis loops. Another analysis
showed that using honeycomb beams as the horizontal beam along
with steel reinforcement has no negative effect on the hysteresis
behavior of the sample.
Abstract: Steel bracing members are widely used in steel
structures to reduce lateral displacement and dissipate energy during
earthquake motions. Concentric steel bracing provide an excellent
approach for strengthening and stiffening steel buildings. Using these
braces the designer can hardly adjust the stiffness together with
ductility as needed because of buckling of braces in compression. In
this study the use of SMA bracing and steel bracing (Mega) utilized
in steel frames are investigated. The effectiveness of these two
systems in rehabilitating a mid-rise eight-storey steel frames were
examined using time-history nonlinear analysis utilizing seismostruct
software. Results show that both systems improve the strength and
stiffness of the original structure but due to excellent behavior of
SMA in nonlinear phase and under compressive forces this system
shows much better performance than the rehabilitation system of
Mega bracing.
Abstract: The cost of damage to the non-structural systems in
critical facilities like nuclear power plants and hospitals can exceed
80% of the total cost of damage during an earthquake. The failure of
nonstructural components, especially, piping systems led to leakage of
water and subsequent shut-down of hospitals immediately after the
event. Consequently, the evaluation of performance of these types of
structural configurations has become necessary to mitigate the risk and
to achieve reliable designs.
This paper focuses on a methodology to evaluate the static and
dynamic characteristics of complex actual piping system based on
NFPA-13 and SMACNA guidelines. The result of this study revealed
that current piping system subjected to design lateral force and design
spectrum based on UBC-97 was failed in both cases and mode shapes
between piping system and building structure were very different