Abstract: Typical load-bearing biological materials like bone,
mineralized tendon and shell, are biocomposites made from both
organic (collagen) and inorganic (biomineral) materials. This
amazing class of materials with intrinsic internally designed
hierarchical structures show superior mechanical properties with
regard to their weak components from which they are formed.
Extensive investigations concentrating on static loading conditions
have been done to study the biological materials failure. However,
most of the damage and failure mechanisms in load-bearing
biological materials will occur whenever their structures are exposed
to dynamic loading conditions. The main question needed to be
answered here is: What is the relation between the layout and
architecture of the load-bearing biological materials and their
dynamic behavior? In this work, a staggered model has been
developed based on the structure of natural materials at nanoscale and
Finite Element Analysis (FEA) has been used to study the dynamic
behavior of the structure of load-bearing biological materials to
answer why the staggered arrangement has been selected by nature to
make the nanocomposite structure of most of the biological materials.
The results showed that the staggered structures will efficiently
attenuate the stress wave rather than the layered structure.
Furthermore, such staggered architecture is effectively in charge of
utilizing the capacity of the biostructure to resist both normal and
shear loads. In this work, the geometrical parameters of the model
like the thickness and aspect ratio of the mineral inclusions selected
from the typical range of the experimentally observed feature sizes
and layout dimensions of the biological materials such as bone and
mineralized tendon. Furthermore, the numerical results validated with
existing theoretical solutions. Findings of the present work emphasize
on the significant effects of dynamic behavior on the natural
evolution of load-bearing biological materials and can help scientists
to design bioinspired materials in the laboratories.
Abstract: Studying stress and strain trends in the femur and
recognizing femur failure mechanism is very important for
preventing hip fracture in the elderly. The aim of this study was to
identify high stress and strain regions in the femur during normal
walking and falling to find the mechanical behavior and failure
mechanism of the femur. We developed a finite element model of the
femur from the subject’s quantitative computed tomography (QCT)
image and used it to identify potentially high stress and strain regions
during the single-leg stance and the sideways fall. It was found that
fracture may initiate from the superior region of femoral neck and
propagate to the inferior region during a high impact force such as
sideways fall. The results of this study showed that the femur bone is
more sensitive to strain than stress which indicates the effect of
strain, in addition to effect of stress, should be considered for failure
analysis.
Abstract: Reliability of long-term storage products is related to
the availability of the whole system, and the evaluation of storage life
is of great necessity. These products are usually highly reliable and
little failure information can be collected. In this paper, an analytical
method based on data from accelerated storage life test is proposed to
evaluate the reliability index of the long-term storage products. Firstly,
singularities are eliminated by data normalization and residual
analysis. Secondly, with the preprocessed data, the degradation path
model is built to obtain the pseudo life values. Then by life distribution
hypothesis, we can get the estimator of parameters in high stress levels
and verify failure mechanism consistency. Finally, the life distribution
under the normal stress level is extrapolated via the acceleration model
and evaluation of the actual average life is available. An application
example with the camera stabilization device is provided to illustrate
the methodology we proposed.
Abstract: The paper deals with the problems of the actual
behavior, failure mechanism and load-carrying capacity of the special
bolt connection developed and intended for the assembly connections
of truss main girders of perspective railway temporary steel bridges.
Within the framework of this problem solution, several types of
structural details of assembly joints have been considered as the
conceptual structural design. Based on the preliminary evaluation of
advantages or disadvantages of these ones, in principle two basic
structural configurations – so-called “tooth” and “splice-plate”
connections have been selected for the subsequent detailed
investigation. This investigation is mainly based on the experimental
verification of the actual behavior, strain and failure mechanism and
corresponding strength of the connection, and on its numerical
modeling using FEM. This paper is focused only on the cyclic
loading (fatigue) tests results of “splice-plate” connections and their
evaluation, which have already been finished. Simultaneously with
the fatigue tests, the static loading tests have been realized too, but
these ones, as well as FEM numerical modeling, are not the subject of
this paper.
Abstract: Hanging to the trapezoidal sheet by decking hanger is a very widespread solution used in civil engineering to lead the distribution of energy, sanitary, air distribution system etc. under the roof or floor structure. The trapezoidal decking hanger is usually a part of the whole installation system for specific distribution medium. The leading companies offer installation systems for each specific distribution e.g. pipe rings, sprinkler systems, installation channels etc. Every specific part is connected to the base connector which is decking hanger. The own connection has three main components: decking hanger, threaded bar with nuts and web of trapezoidal sheet. The aim of this contribution is determinate the failure mechanism of each component in connection. Load bearing capacity of most components in connection could be calculated by formulas in European codes. This contribution is focused on problematic of bearing resistance of threaded bar in web of trapezoidal sheet. This issue is studied by experimental research and numerical modelling. This contribution presented the initial results of experiment which is compared with numerical model of specimen.
Abstract: Based on the kinematic approach of limit analysis, a full set of upper bound solutions for the stability of homogeneous rock slopes subjected to tension cracks are obtained. The generalized Hoek-Brown failure criterion is employed to describe the non-linear strength envelope of rocks. In this paper, critical failure mechanisms are determined for cracks of known depth but unspecified location, cracks of known location but unknown depth, and cracks of unspecified location and depth. It is shown that there is a nearly up to 50% drop in terms of the stability factors for the rock slopes intersected by a tension crack compared with intact ones. Tables and charts of solutions in dimensionless forms are presented for ease of use by practitioners.
Abstract: Thermally insulating ceramic coatings also known as
thermal barrier coatings (TBCs) have been essential technologies to
improve the performance and efficiency of advanced gas turbines in
service at extremely high temperatures. The damage mechanisms of
air-plasma sprayed YSZ thermal barrier coatings (TBC) with various
microstructures were studied by microscopic techniques after thermal
cycling. The typical degradation of plasma TBCs that occurs during
cyclic furnace testing of an YSZ and alumina coating on a Titanium
alloy are analyzed. During the present investigation the effects of
topcoat thickness, bond coat oxidation, thermal cycle lengths and test
temperature are investigated using thermal cycling. These results
were correlated with stresses measured by a spectroscopic technique
in order to understand specific damage mechanism. The failure
mechanism of former bond coats was found to involve fracture
initiation at the thermally grown oxide (TGO) interface and at the
TGO bond coat interface. The failure mechanism of the YZ was
found to involve combination of fracture along the interface between
TGO and bond coat.
Abstract: In the present paper the results of a numerical study are presented, numerical models were developed to simulate the behaviour of vertical massive dikes. The proposed models were developed according to the geometry, boundary conditions, loading conditions and initial conditions of a physical model taken as reference. The results obtained were compared to the experimental data. As far as the overall behaviour, the displacements and the failure mechanisms of the dikes is concerned, the numerical results were in good agreement with the experimental results, which clearly indicates a good quality of numerical modelling. The validated numerical models were used in a parametric study were the displacements and failure mechanisms were fully investigated. Out of the results obtained, some conclusions and recommendations related to the design of massive dikes are proposed.
Abstract: In this study acoustic emission (AE) signals obtained during deformation and fracture of two types of ferrite-martensite dual phase steels (DPS) specimens have been analyzed in frequency domain. For this reason two low carbon steels with various amounts of carbon were chosen, and intercritically heat treated. In the introduced method, identifying the mechanisms of failure in the various phases of DPS is done. For this aim, AE monitoring has been used during tensile test of several DPS with various volume fraction of the martensite (VM) and attempted to relate the AE signals and failure mechanisms in these steels. Different signals, which referred to 2-3 micro-mechanisms of failure due to amount of carbon and also VM have been seen. By Fast Fourier Transformation (FFT) of signals in distinct locations, an excellent relationship between peak frequencies in these areas and micro-mechanisms of failure were seen. The results were verified by microscopic observations (SEM).
Abstract: This paper focuses on the Mega-Sub Controlled
Structure Systems (MSCSS) performances and characteristics
regarding the new control principle contained in MSCSS subjected to
strong earthquake excitations. The adopted control scheme consists of
modulated sub-structures where the control action is achieved by
viscous dampers and sub-structure own configuration. The
elastic-plastic time history analysis under severe earthquake excitation
is analyzed base on the Finite Element Analysis Method (FEAM), and
some comparison results are also given in this paper. The result shows
that the MSCSS systems can remarkably reduce vibrations effects
more than the mega-sub structure (MSS). The study illustrates that the
improved MSCSS presents good seismic resistance ability even at 1.2g
and can absorb seismic energy in the structure, thus imply that
structural members cross section can be reduce and achieve to good
economic characteristics. Furthermore, the elasto-plastic analysis
demonstrates that the MSCSS is accurate enough regarding
international building evaluation and design codes. This paper also
shows that the elasto-plastic dynamic analysis method is a reasonable
and reliable analysis method for structures subjected to strong
earthquake excitations and that the computed results are more precise.
Abstract: The electrical substation components are often subject to degradation due to over-voltage or over-current, caused by a short circuit or a lightning. A particular interest is given to the circuit breaker, regarding the importance of its function and its dangerous failure. This component degrades gradually due to the use, and it is also subject to the shock process resulted from the stress of isolating the fault when a short circuit occurs in the system. In this paper, based on failure mechanisms developments, the wear out of the circuit breaker contacts is modeled. The aim of this work is to evaluate its reliability and consequently its residual lifetime. The shock process is based on two random variables such as: the arrival of shocks and their magnitudes. The arrival of shocks was modeled using homogeneous Poisson process (HPP). By simulation, the dates of short-circuit arrivals were generated accompanied with their magnitudes. The same principle of simulation is applied to the amount of cumulative wear out contacts. The objective reached is to find the formulation of the wear function depending on the number of solicitations of the circuit breaker.
Abstract: Structural performance and seismic vulnerability of
masonry buildings in Algeria are investigated in this paper. Structural
classification of such buildings is carried out regarding their
structural elements. Seismicity of Algeria is briefly discussed. Then
vulnerability of masonry buildings and their failure mechanisms in
the Boumerdes earthquake (May, 2003) are examined.
Abstract: Dual phase steels (DPS)s have a microstructure
consisting of a hard second phase called Martensite in the soft Ferrite
matrix. In recent years, there has been interest in dual-phase steels,
because the application of these materials has made significant usage;
particularly in the automotive sector Composite microstructure of
(DPS)s exhibit interesting characteristic mechanical properties such
as continuous yielding, low yield stress to tensile strength
ratios(YS/UTS), and relatively high formability; which offer
advantages compared with conventional high strength low alloy
steels(HSLAS). The research dealt with the characterization of
damage in (DPS)s. In this study by review the mechanisms of failure
due to volume fraction of martensite second phase; a new method is
introduced to identifying the mechanisms of failure in the various
phases of these types of steels. In this method the acoustic emission
(AE) technique was used to detect damage progression. These failure
mechanisms consist of Ferrite-Martensite interface decohesion and/or
martensite phase fracture. For this aim, dual phase steels with
different volume fraction of martensite second phase has provided by
various heat treatment methods on a low carbon steel (0.1% C), and
then AE monitoring is used during tensile test of these DPSs. From
AE measurements and an energy ratio curve elaborated from the
value of AE energy (it was obtained as the ratio between the strain
energy to the acoustic energy), that allows detecting important
events, corresponding to the sudden drops. These AE signals events
associated with various failure mechanisms are classified for ferrite
and (DPS)s with various amount of Vm and different martensite
morphology. It is found that AE energy increase with increasing Vm.
This increasing of AE energy is because of more contribution of
martensite fracture in the failure of samples with higher Vm. Final
results show a good relationship between the AE signals and the
mechanisms of failure.
Abstract: Historic religious buildings located in seismic areas
have developed different failure mechanisms. Simulation of failure
modes is done with computer programs through a nonlinear dynamic
analysis or simplified using the method of failure blocks. Currently
there are simulation methodologies of failure modes based on the
failure rigid blocks method only for Roman Catholic churches type.
Due to differences of shape in plan, elevation and construction
systems between Orthodox churches and Catholic churches, for the
first time there were initiated researches in the development of this
simulation methodology for Orthodox churches. In this article are
presented the first results from the researches. The theoretical results
were compared with real failure modes recorded at an Orthodox
church from Banat region, severely damaged by earthquakes in
1991. Simulated seismic response, using a computer program based
on finite element method was confirmed by cracks after earthquakes.
The consolidation of the church was made according to these
theoretical results, realizing a rigid floor connecting all the failure
blocks.
Abstract: Safety instrumented systems (SISs) are becoming
increasingly complex and the proportion of programmable electronic
parts is growing. The IEC 61508 global standard was established to
ensure the functional safety of SISs, but it was expressed in highly
macroscopic terms. This study introduces an evaluation process for
hardware safety integrity levels through failure modes, effects, and
diagnostic analysis (FMEDA).FMEDA is widely used to evaluate
safety levels, and it provides the information on failure rates and
failure mode distributions necessary to calculate a diagnostic coverage
factor for a given component. In our evaluation process, the
components of the SIS subsystem are first defined in terms of failure
modes and effects. Then, the failure rate and failure mechanism
distribution are assigned to each component. The safety mode and
detectability of each failure mode are determined for each component.
Finally, the hardware safety integrity level is evaluated based on the
calculated results.
Abstract: This paper proposes a methodology for mitigating the occurrence of cascading failure in stressed power systems. The methodology is essentially based on predicting voltage instability in the power system using a voltage stability index and then devising a corrective action in order to increase the voltage stability margin. The paper starts with a brief description of the cascading failure mechanism which is probable root cause of severe blackouts. Then, the voltage instability indices are introduced in order to evaluate stability limit. The aim of the analysis is to assure that the coordination of protection, by adopting load shedding scheme, capable of enhancing performance of the system after the major location of instability is determined. Finally, the proposed method to generate instability prediction is introduced.
Abstract: C-control chart assumes that process nonconformities follow a Poisson distribution. In actuality, however, this Poisson distribution does not always occur. A process control for semiconductor based on a Poisson distribution always underestimates the true average amount of nonconformities and the process variance. Quality is described more accurately if a compound Poisson process is used for process control at this time. A cumulative sum (CUSUM) control chart is much better than a C control chart when a small shift will be detected. This study calculates one-sided CUSUM ARLs using a Markov chain approach to construct a CUSUM control chart with an underlying Poisson-Gamma compound distribution for the failure mechanism. Moreover, an actual data set from a wafer plant is used to demonstrate the operation of the proposed model. The results show that a CUSUM control chart realizes significantly better performance than EWMA.