Abstract: This paper describes the development of a fully
automated measurement software for antenna radiation pattern
measurements in a Compact Antenna Test Range (CATR). The
CATR has a frequency range from 2-40 GHz and the measurement
hardware includes a Network Analyzer for transmitting and
Receiving the microwave signal and a Positioner controller to control
the motion of the Styrofoam column. The measurement process
includes Calibration of CATR with a Standard Gain Horn (SGH)
antenna followed by Gain versus angle measurement of the Antenna
under test (AUT). The software is designed to control a variety of
microwave transmitter / receiver and two axis Positioner controllers
through the standard General Purpose interface bus (GPIB) interface.
Addition of new Network Analyzers is supported through a slight
modification of hardware control module. Time-domain gating is
implemented to remove the unwanted signals and get the isolated
response of AUT. The gated response of the AUT is compared with
the calibration data in the frequency domain to obtain the desired
results. The data acquisition and processing is implemented in
Agilent VEE and Matlab. A variety of experimental measurements
with SGH antennas were performed to validate the accuracy of
software. A comparison of results with existing commercial
softwares is presented and the measured results are found to be
within .2 dBm.
Abstract: In geometrical camera calibration, the objective is to
determine a set of camera parameters that describe the mapping
between 3D references coordinates and 2D image coordinates. In this
paper, a technique of calibration and tracking based on both a least
squares method is presented and a correlation technique developed as
part of an augmented reality system. This approach is fast and it can
be used for a real time system
Abstract: Flash floods are considered natural disasters that can
cause casualties and demolishing of infra structures. The problem is
that flash floods, particularly in arid and semi arid zones, take place
in very short time. So, it is important to forecast flash floods earlier to
its events with a lead time up to 48 hours to give early warning alert
to avoid or minimize disasters. The flash flood took place over Wadi
Watier - Sinai Peninsula, in October 24th, 2008, has been simulated,
investigated and analyzed using the state of the art regional weather
model. The Weather Research and Forecast (WRF) model, which is a
reliable short term forecasting tool for precipitation events, has been
utilized over the study area. The model results have been calibrated
with the real data, for the same date and time, of the rainfall
measurements recorded at Sorah gauging station. The WRF model
forecasted total rainfall of 11.6 mm while the real measured one was
10.8 mm. The calibration shows significant consistency between
WRF model and real measurements results.
Abstract: InGaAsN and GaAsN epitaxial layers with similar
nitrogen compositions in a sample were successfully grown on a
GaAs (001) substrate by solid source molecular beam epitaxy. An
electron cyclotron resonance nitrogen plasma source has been used to
generate atomic nitrogen during the growth of the nitride layers. The
indium composition changed from sample to sample to give
compressive and tensile strained InGaAsN layers. Layer
characteristics have been assessed by high-resolution x-ray
diffraction to determine the relationship between the lattice constant
of the GaAs1-yNy layer and the fraction x of In. The objective was to
determine the In fraction x in an InxGa1-xAs1-yNy epitaxial layer which
exactly cancels the strain present in a GaAs1-yNy epitaxial layer with
the same nitrogen content when grown on a GaAs substrate.
Abstract: BRI-STARS (BRIdge Stream Tube model for Alluvial
River Simulation) program was used to investigate the scour depth around bridge piers in some of the major river systems in Iran. Model
calibration was performed by collecting different field data. Field data are cataloged on three categories, first group of bridges that
their rivers bed are formed by fine material, second group of bridges
that their rivers bed are formed by sand material, and finally bridges that their rivers bed are formed by gravel or cobble materials.
Verification was performed with some field data in Fars Province. Results show that for wide piers, computed scour depth is more than
measured one. In gravel bed streams, computed scour depth is greater
than measured scour depth, the reason is due to formation of armor layer on bed of channel. Once this layer is eroded, the computed
scour depth is close to the measured one.
Abstract: The hard clam (meretrix lusoria) cultivated industry
has been developed vigorously for recent years in Taiwan, and
seawater quality determines the cultivated environment. The pH
concentration variation affects survival rate of meretrix lusoria
immediately. In order to monitor seawater quality, solid-state sensing
electrode of ruthenium-doped titanium dioxide (TiO2:Ru) is developed
to measure hydrogen ion concentration in different cultivated
solutions. Because the TiO2:Ru sensing electrode has high chemical
stability and superior sensing characteristics, thus it is applied as a pH
sensor. Response voltages of TiO2:Ru sensing electrode are readout by
instrument amplifier in different sample solutions. Mean sensitivity
and linearity of TiO2:Ru sensing electrode are 55.20 mV/pH and 0.999
from pH1 to pH13, respectively. We expect that the TiO2:Ru sensing
electrode can be applied to real environment measurement, therefore
we collect two sample solutions by different meretrix lusoria
cultivated ponds in the Yunlin, Taiwan. The two sample solutions are
both measured for 200 seconds after calibration of standard pH buffer
solutions (pH7, pH8 and pH 9). Mean response voltages of sample 1
and sample 2 are -178.758 mV (Standard deviation=0.427 mV) and
-180.206 mV (Standard deviation =0.399 mV), respectively. Response
voltages of the two sample solutions are between pH 8 and pH 9 which
conform to weak alkali range and suitable meretrix lusoria growth. For
long-term monitoring, drift of cultivated solutions (sample 1 and
sample 2) are 1.16 mV/hour and 1.03 mV/hour, respectively.
Abstract: Acute toxicity of nano SiO2, ZnO, MCM-41 (Meso
pore silica), Cu, Multi Wall Carbon Nano Tube (MWCNT), Single
Wall Carbon Nano Tube (SWCNT) , Fe (Coated) to bacteria Vibrio
fischeri using a homemade luminometer , was evaluated. The values
of the nominal effective concentrations (EC), causing 20% and 50%
inhibition of biouminescence, using two mathematical models at two
times of 5 and 30 minutes were calculated. Luminometer was
designed with Photomultiplier (PMT) detector. Luminol
chemiluminescence reaction was carried out for the calibration graph.
In the linear calibration range, the correlation coefficients and
coefficient of Variation (CV) were 0.988 and 3.21% respectively
which demonstrate the accuracy and reproducibility of the instrument
that are suitable. The important part of this research depends on how
to optimize the best condition for maximum bioluminescence. The
culture of Vibrio fischeri with optimal conditions in liquid media,
were stirring at 120 rpm at a temperature of 150C to 180C and were
incubated for 24 to 72 hours while solid medium was held at 180C
and for 48 hours. Suspension of nanoparticles ZnO, after 30 min
contact time to bacteria Vibrio fischeri, showed the highest toxicity
while SiO2 nanoparticles showed the lowest toxicity. After 5 min
exposure time, the toxicity of ZnO was the strongest and MCM-41
was the weakest toxicant component.
Abstract: In this paper as showed a non-invasive 3D eye tracker
for optometry clinical applications. Measurements of biomechanical
variables in clinical practice have many font of errors associated with
traditional procedments such cover test (CT), near point of
accommodation (NPC), eye ductions (ED), eye vergences (EG) and,
eye versions (ES). Ocular motility should always be tested but all
evaluations have a subjective interpretations by practitioners, the
results is based in clinical experiences, repeatability and accuracy
don-t exist. Optometric-lab is a tool with 3 (tree) analogical video
cameras triggered and synchronized in one acquisition board AD.
The variables globe rotation angle and velocity can be quantified.
Data record frequency was performed with 27Hz, camera calibration
was performed in a know volume and image radial distortion
adjustments.
Abstract: Applying a rigorous process to optimize the elements
of a supply-chain network resulted in reduction of the waiting time
for a service provider and customer. Different sources of downtime
of hydraulic pressure controller/calibrator (HPC) were causing
interruptions in the operations. The process examined all the issues to
drive greater efficiencies. The issues included inherent design issues
with HPC pump, contamination of the HPC with impurities, and the
lead time required for annual calibration in the USA.
HPC is used for mandatory testing/verification of formation
tester/pressure measurement/logging-while drilling tools by oilfield
service providers, including Halliburton.
After market study andanalysis, it was concluded that the current
HPC model is best suited in the oilfield industry. To use theexisting
HPC model effectively, design andcontamination issues were
addressed through design and process improvements. An optimum
network is proposed after comparing different supply-chain models
for calibration lead-time reduction.
Abstract: Camera calibration plays an important role in the domain of the analysis of sports video. Considering soccer video, in most cases, the cross-points can be used for calibration at the center of the soccer field are not sufficient, so this paper introduces a new automatic camera calibration algorithm focus on solving this problem by using the properties of images of the center circle, halfway line and a touch line. After the theoretical analysis, a practicable automatic algorithm is proposed. Very little information used though, results of experiments with both synthetic data and real data show that the algorithm is applicable.
Abstract: A new fast correlation algorithm for calibrating the
wavelength of Optical Spectrum Analyzers (OSAs) was introduced
in [1]. The minima of acetylene gas spectra were measured and
correlated with saved theoretical data [2]. So it is possible to find the
correct wavelength calibration data using a noisy reference spectrum.
First tests showed good algorithmic performance for gas line spectra
with high noise. In this article extensive performance tests were made
to validate the noise resistance of this algorithm. The filter and
correlation parameters of the algorithm were optimized for improved
noise performance. With these parameters the performance of this
wavelength calibration was simulated to predict the resulting
wavelength error in real OSA systems. Long term simulations were
made to evaluate the performance of the algorithm over the lifetime
of a real OSA.
Abstract: Camera calibration is an important step in 3D
reconstruction. Camera calibration may be classified into two major types: traditional calibration and self-calibration. However, a calibration method in using a checkerboard is intermediate between traditional calibration and self-calibration. A self
is proposed based on a square in this paper. Only a square in the planar
template, the camera self-calibration can be completed through the single view. The proposed algorithm is that the virtual circle and straight line are established by a square on planar template, and
circular points, vanishing points in straight lines and the relation
between them are be used, in order to obtain the image of the absolute
conic (IAC) and establish the camera intrinsic parameters. To make
the calibration template is simpler, as compared with the Zhang Zhengyou-s method. Through real experiments and experiments, the experimental results show that this algorithm is
feasible and available, and has a certain precision and robustness.
Abstract: During the process of compaction in Hot-Mix Asphalt
(HMA) mixtures, the distance between aggregate particles decreases
as they come together and eliminate air-voids. By measuring the
inter-particle distances in a cut-section of a HMA sample the degree
of compaction can be estimated. For this, a calibration curve is
generated by computer simulation technique when the gradation and
asphalt content of the HMA mixture are known. A two-dimensional
cross section of HMA specimen was simulated using the mixture
design information (gradation, asphalt content and air-void content).
Nearest neighbor distance methods such as Delaunay triangulation
were used to study the changes in inter-particle distance and area
distribution during the process of compaction in HMA. Such
computer simulations would enable making several hundreds of
repetitions in a short period of time without the necessity to compact
and analyze laboratory specimens in order to obtain good statistics on
the parameters defined. The distributions for the statistical
parameters based on computer simulations showed similar trends as
those of laboratory specimens.
Abstract: The Principal component regression (PCR) is a
combination of principal component analysis (PCA) and multiple linear regression (MLR). The objective of this paper is to revise the
use of PCR in shortwave near infrared (SWNIR) (750-1000nm) spectral analysis. The idea of PCR was explained mathematically and
implemented in the non-destructive assessment of the soluble solid
content (SSC) of pineapple based on SWNIR spectral data. PCR achieved satisfactory results in this application with root mean
squared error of calibration (RMSEC) of 0.7611 Brix°, coefficient of determination (R2) of 0.5865 and root mean squared error of crossvalidation
(RMSECV) of 0.8323 Brix° with principal components
(PCs) of 14.
Abstract: In this study three commercial semiconductor devices
were characterized in the laboratory for computed tomography
dosimetry: one photodiode and two phototransistors. It was evaluated
four responses to the irradiation: dose linearity, energy dependence,
angular dependence and loss of sensitivity after X ray exposure. The
results showed that the three devices have proportional response with
the air kerma; the energy dependence displayed for each device
suggests that some calibration factors would be applied for each one;
the angular dependence showed a similar pattern among the three
electronic components. In respect to the fourth parameter analyzed,
one phototransistor has the highest sensitivity however it also showed
the greatest loss of sensitivity with the accumulated dose. The
photodiode was the device with the smaller sensitivity to radiation,
on the other hand, the loss of sensitivity after irradiation is negligible.
Since high accuracy is a desired feature for a dosimeter, the
photodiode can be the most suitable of the three devices for
dosimetry in tomography. The phototransistors can also be used for
CT dosimetry, however it would be necessary a correction factor due
to loss of sensitivity with accumulated dose.
Abstract: In this work, propagation of uncertainty during calibration
process of TRANUS, an integrated land use and transport model
(ILUTM), has been investigated. It has also been examined, through a
sensitivity analysis, which input parameters affect the variation of the
outputs the most. Moreover, a probabilistic verification methodology
of calibration process, which equates the observed and calculated
production, has been proposed. The model chosen as an application is
the model of the city of Grenoble, France. For sensitivity analysis and
uncertainty propagation, Monte Carlo method was employed, and a
statistical hypothesis test was used for verification. The parameters of
the induced demand function in TRANUS, were assumed as uncertain
in the present case. It was found that, if during calibration, TRANUS
converges, then with a high probability the calibration process is
verified. Moreover, a weak correlation was found between the inputs
and the outputs of the calibration process. The total effect of the
inputs on outputs was investigated, and the output variation was found
to be dictated by only a few input parameters.
Abstract: This research was conducted in the Lower Ping River
Basin downstream of the Bhumibol Dam and the Lower Wang River
Basin in Tak Province, Thailand. Most of the tributary streams of the
Ping can be considered as ungauged catchments. There are 10-
pumping station installation at both river banks of the Ping in Tak
Province. Recently, most of them could not fully operate due to the
water amount in the river below the level that would be pumping,
even though included water from the natural river and released flow
from the Bhumibol Dam. The aim of this research was to increase the
performance of those pumping stations using weir projects in the
Ping. Therefore, the river analysis system model (HEC-RAS) was
applied to study the hydraulic behavior of water surface profiles in
the Ping River with both cases of existing conditions and proposed
weirs during the violent flood in 2011 and severe drought in 2013.
Moreover, the hydrologic modeling system (HMS) was applied to
simulate lateral streamflow hydrograph from ungauged catchments of
the Ping. The results of HEC-RAS model calibration with existing
conditions in 2011 showed best trial roughness coefficient for the
main channel of 0.026. The simulated water surface levels fitted to
observation data with R2 of 0.8175. The model was applied to 3
proposed cascade weirs with 2.35 m in height and found surcharge
water level only 0.27 m higher than the existing condition in 2011.
Moreover, those weirs could maintain river water levels and increase
of those pumping performances during less river flow in 2013.
Abstract: Time interleaved sigma-delta (TIΣΔ) architecture is a
potential candidate for high bandwidth analog to digital converters
(ADC) which remains a bottleneck for software and cognitive radio
receivers. However, the performance of the TIΣΔ architecture is
limited by the unavoidable gain and offset mismatches resulting
from the manufacturing process. This paper presents a novel digital
calibration method to compensate the gain and offset mismatch
effect. The proposed method takes advantage of the reconstruction
digital signal processing on each channel and requires only few logic
components for implementation. The run time calibration is estimated
to 10 and 15 clock cycles for offset cancellation and gain mismatch
calibration respectively.
Abstract: This paper suggests a calibration method to reduce
errors occurring due to mobile robot sliding during location estimation
using the Dead-reckoning. Due to sliding of the mobile robot caused
between its wheels and the road surface while on free run, location
estimation can be erroneous. Sliding especially occurs during
cornering of mobile robot. Therefore, in order to reduce these frequent
sliding errors in cornering, we calibrated the mobile robot-s heading
values using a vision camera and templates of the ceiling.
Abstract: Simulation is a very powerful method used for highperformance
and high-quality design in distributed system, and now
maybe the only one, considering the heterogeneity, complexity and
cost of distributed systems. In Grid environments, foe example, it is
hard and even impossible to perform scheduler performance
evaluation in a repeatable and controllable manner as resources and
users are distributed across multiple organizations with their own
policies. In addition, Grid test-beds are limited and creating an
adequately-sized test-bed is expensive and time consuming.
Scalability, reliability and fault-tolerance become important
requirements for distributed systems in order to support distributed
computation. A distributed system with such characteristics is called
dependable. Large environments, like Cloud, offer unique
advantages, such as low cost, dependability and satisfy QoS for all
users. Resource management in large environments address
performant scheduling algorithm guided by QoS constrains. This
paper presents the performance evaluation of scheduling heuristics
guided by different optimization criteria. The algorithms for
distributed scheduling are analyzed in order to satisfy users
constrains considering in the same time independent capabilities of
resources. This analysis acts like a profiling step for algorithm
calibration. The performance evaluation is based on simulation. The
simulator is MONARC, a powerful tool for large scale distributed
systems simulation. The novelty of this paper consists in synthetic
analysis results that offer guidelines for scheduler service
configuration and sustain the empirical-based decision. The results
could be used in decisions regarding optimizations to existing Grid
DAG Scheduling and for selecting the proper algorithm for DAG
scheduling in various actual situations.